Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures

被引:0
作者
Mandala, Meghana [1 ]
Shaunak, Shalin [2 ]
Kreitmair, Paul [3 ]
Phadnis, Joideep [2 ]
Guryel, Enis [2 ]
机构
[1] Brighton & Sussex Med Sch, Brighton, England
[2] Univ Hosp Sussex NHS Fdn Trust, Brighton, England
[3] Univ Sussex, Brighton, England
关键词
Intra-articular fractures; Headless compression screws; Locking screws; Acutrak; Synthes; Smith and Nephew; Compression force; INTERFRAGMENTARY COMPRESSION; HERBERT SCREW; LAG SCREW; FIXATION;
D O I
10.1007/s00590-023-03792-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Headless compression screws (HCS) have a variable thread pitch and headless design enabling them to embed below the articular surface and generate compression force for fracture healing without restricting movement. Locking screws have greater variety of dimensions and a threaded pitch mirroring the design of the HCS. The objective of this study is to determine whether locking screws can generate compression force and compare the compressive forces generated by HCS versus locking screws.Method A comparison between 3.5-mm HCS versus 3.5-mm locking screws and 2.8-mm HCS versus 2.7-mm locking screws was performed using a synthetic foam bone model (Synbone) and FlexiForce sensors to record the compression forces (N). The mean peak compression force was calculated from a sample of 3 screws for each screw type. Statistical analysis was performed using the one-way ANOVA test and statistical significance was determined to be p = < 0.05.Results The 3.5-mm Synthes and Smith and Nephew locking screws generated similar peak compression forces to the 3.5-mm Acutrak 2 headless compression screws with no statistically significant difference between them. The smaller 2.7-mm Synthes and Smith and Nephew locking screws initially generated similar compressive forces up to 1.5 and 2 revolutions, respectively, but their peak compression force was less compared to the 2.8-mm Micro Acutrak 2 HCS.Conclusion Locking screws are able to generate compressive forces and may be a viable alternative to headless compressive screws supporting their use for intra-articular fractures.
引用
收藏
页码:1319 / 1325
页数:7
相关论文
共 19 条
  • [1] Biomechanical analysis of second-generation headless compression screws
    Assari, Soroush
    Darvish, Kurosh
    Ilyas, Asif M.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07): : 1159 - 1165
  • [2] Interfragmentary compression across a simulated scaphoid fracture - Analysis of 3 screws
    Beadel, GP
    Ferreira, L
    Johnson, JA
    King, GJW
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (02): : 273 - 278
  • [3] Screw fixation of radial head fractures: Compression screw versus lag screw-A biomechanical comparison
    Burkhart, Klaus J.
    Nowak, Tobias E.
    Appelmann, Philipp
    Sternstein, Werner
    Rommens, Pol M.
    Mueller, Lars P.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1015 - 1019
  • [4] Biomechanics of locked plates and screws
    Egol, KA
    Kubiak, EN
    Fulkerson, E
    Kummer, FJ
    Koval, KJ
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 488 - 493
  • [5] Felstead Alisdair J, 2019, Tech Hand Up Extrem Surg, V23, P33, DOI 10.1097/BTH.0000000000000220
  • [6] Comparison of headless screws used in the treatment of proximal nonunion of scaphoid bone
    Gereli, Arel
    Nalbantoglu, Ufuk
    Sener, Ismail Ugur
    Kocaoglu, Baris
    Turkmen, Metin
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (07) : 1031 - 1035
  • [7] A comparison of two headless compression screws for operative treatment of scaphoid fractures
    Grewal, Ruby
    Assini, Joseph
    Sauder, David
    Ferreira, Louis
    Johnson, Jim
    Faber, Kenneth
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2011, 6
  • [8] Impact of Different Screw Designs on Durability of Fracture Fixation: In Vitro Study with Cyclic Loading of Scaphoid Bones
    Gruszka, Dominik
    Herr, Robert
    Hely, Hans
    Hofmann, Peer
    Klitscher, Daniela
    Hofmann, Alexander
    Rommens, Pol Maria
    [J]. PLOS ONE, 2016, 11 (01):
  • [9] Interfragmentary compression forces of scaphoid screws in a sawbone cylinder model
    Hausmann, J. T.
    Mayr, W.
    Unger, E.
    Benesch, T.
    Vecsei, V.
    Gaebler, C.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (07): : 763 - 768
  • [10] MANAGEMENT OF THE FRACTURED SCAPHOID USING A NEW BONE SCREW
    HERBERT, TJ
    FISHER, WE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (01): : 114 - 123