Schrödinger spectrum based continuous cuff-less blood pressure estimation using clinically relevant features from PPG signal and its second derivative

被引:12
作者
Sarkar, Sayan [1 ]
Ghosh, Aayushman [2 ,3 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Elect & Comp Engn, Hong Kong, Peoples R China
[2] Indian Inst Engn Sci & Technol, Dept Elect & Telecommun Engn, Howrah 11103, India
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
关键词
Continuous BP monitoring; Regression algorithms; Photoplethysmogram; Pulse Wave Analysis; Pulse wave decomposition; Bio-signal database; Signal processing framework; PULSE ARRIVAL-TIME; PHOTOPLETHYSMOGRAPHY; VALIDATION; SCATTERING; BENCHMARK;
D O I
10.1016/j.compbiomed.2023.107558
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The presented study estimates cuff-less blood pressure (BP) from photoplethysmography (PPG) signals using multiple machine-learning (ML) models and the semi-classical signal analysis (SCSA) technique. The study proposes a novel signal reconstruction algorithm, which optimizes the semi-classical constant of the SCSA approach and eliminates the trade-off between complexity and accuracy during signal reconstruction. It predicts BP values using regression algorithms by processing reconstructed PPG signals' spectral features, extracting clinically relevant PPG and its second derivative's (SDPPG) morphological features. The developed method was assessed using a virtual in-silico dataset with more than 4000 subjects and the Multi-Parameter Intelligent Monitoring in Intensive Care Units (MIMIC-II) dataset. Results showed that the method attained a mean absolute error (MAE) of 5.37 and 2.96 mmHg for systolic and diastolic BP, respectively, using the CatBoost algorithm. This approach met the Association for the Advancement of Medical Instrumentation's standard and achieved Grade A for all BP categories in the British Hypertension Society protocol. The proposed framework performs well even when applied to a combined clinically relevant database originating from MIMIC-III and the Queensland dataset. The proposed method's performance is further evaluated in a non-clinical setting with noisy and deformed PPG signals to validate the efficacy of the SCSA method. The noise stress tests further showed that the algorithm maintained its key feature detection, signal reconstruction capability, and estimation accuracy up to a 10 dB SNR ratio. The proposed cuff-less BP estimation technique has the potential to perform well in mobile healthcare devices due to its straightforward implementation approach.
引用
收藏
页数:16
相关论文
共 83 条
[1]  
Abualigah L.M.Q., 2019, Feature selection and enhanced krill herd algorithm for text document clustering, V816, DOI DOI 10.1007/978-3-030-10674-4
[2]   Reptile Search Algorithm (RSA): A nature-inspired meta-heuristic optimizer [J].
Abualigah, Laith ;
Abd Elaziz, Mohamed ;
Sumari, Putra ;
Geem, Zong Woo ;
Gandomi, Amir H. .
EXPERT SYSTEMS WITH APPLICATIONS, 2022, 191
[3]   Aquila Optimizer: A novel meta-heuristic optimization algorithm [J].
Abualigah, Laith ;
Yousri, Dalia ;
Abd Elaziz, Mohamed ;
Ewees, Ahmed A. ;
Al-qaness, Mohammed A. A. ;
Gandomi, Amir H. .
COMPUTERS & INDUSTRIAL ENGINEERING, 2021, 157 (157)
[4]   The Arithmetic Optimization Algorithm [J].
Abualigah, Laith ;
Diabat, Ali ;
Mirjalili, Seyedali ;
Elaziz, Mohamed Abd ;
Gandomi, Amir H. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2021, 376
[5]   Dwarf Mongoose Optimization Algorithm [J].
Agushaka, Jeffrey O. ;
Ezugwu, Absalom E. ;
Abualigah, Laith .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2022, 391
[6]   A Novel Interpretation for Arterial Pulse Pressure Amplification in Health and Disease [J].
Alfonso, Manuel R. ;
Armentano, Ricardo L. ;
Cymberknop, Leandro J. ;
Ghigo, Arthur R. ;
Pessana, Franco M. ;
Legnani, Walter E. .
JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
[7]  
Association for the Advancement Instrumentation, 2002, ANSI/ AAMI SP 10 2002
[8]   An Estimation Method of Continuous Non-Invasive Arterial Blood Pressure Waveform Using Photoplethysmography: A U-Net Architecture-Based Approach [J].
Athaya, Tasbiraha ;
Choi, Sunwoong .
SENSORS, 2021, 21 (05) :1-18
[9]   A computationally efficient CNN-LSTM neural network for estimation of blood pressure from features of electrocardiogram and photoplethysmogram waveforms [J].
Baker, Stephanie ;
Xiang, Wei ;
Atkinson, Ian .
KNOWLEDGE-BASED SYSTEMS, 2022, 250
[10]  
Baruch Martin C, 2011, Nonlinear Biomed Phys, V5, P1, DOI 10.1186/1753-4631-5-1