3D PRINTED CUSTOMIZED CAD-CAM IMPLANT ABUTMENT FOR CORRECTION OF ANGULATED IMPLANT IN ESTHETIC ZONE-A CASE REPORT

被引:0
作者
Maiti, Subhabrata [1 ]
Rai, Nitesh [2 ]
Appanna, Ponnanna [2 ]
Paulraj, Jessy [3 ]
机构
[1] Saveetha Univ Chennai, Saveetha Inst Med & Tech Sci, Saveetha Dent Coll & Hosp, Dept Prosthodont, Chennai 77, Tamil Nadu, India
[2] Krishnadevaraya Coll Dent Sci & Hosp Bangalore, Dept Prosthodont, Bangalore, Karnataka, India
[3] Saveetha Univ Chennai, Saveetha Inst Med & Tech Sci, Saveetha Dent Coll & Hosp, Dept Pedodont, Chennai, Tamil Nadu, India
来源
ANNALS OF DENTAL SPECIALTY | 2023年 / 11卷 / 02期
关键词
Custom abutment; 3D printing; Angulated implant; CAD CAM; Esthetic; Digital dentistry;
D O I
10.51847/GUxhI7gCjJ
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aesthetic is always a key consideration for patients needing anterior teeth. An implant is the first choice of treatment in modern dentistry. Due to bone availability or underlying anatomical structure, implant placement may not always be favorable. With customized digital design and manufacturing using 3D printing DMLS technology, prosthetic management of angulated implants can produce results that are much more accurate, precise, and error-free. This case report will explain a case of a 38 years old female patient with grade III mobile teeth who was rehabilitated with CADCAM customized partial hybrid prosthesis where from the beginning of the case aesthetic was the prime factor. Immediate denture was planned along with natural teeth as denture teeth in order to preserve the eathetics. CAD CAM abutment was excellent in accuracy where internal fit was done digitally through scan body and digital analog and superstructure framework was made based on digital wax up; then it was layered with indirect composite for high esthetic and easy repair. Screw retained prosthesis was planned for easy recovery and maintenance. The aesthetic rehabilitation in advance of digital implant dentistry is the prime focus of this case report.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 18 条
  • [1] Chow J, 2020, ZYGOMATIC IMPLANTS O
  • [2] Drago Carl., 2020, Implant Restorations: Step-by-Step Guide, VFourth
  • [3] Artificial intelligence in fixed implant prosthodontics: a retrospective study of 106 implant-supported monolithic zirconia crowns inserted in the posterior jaws of 90 patients
    Lerner, Henriette
    Mouhyi, Jaafar
    Admakin, Oleg
    Mangano, Francesco
    [J]. BMC ORAL HEALTH, 2020, 20 (01)
  • [4] Survival rates of ultra-short (<6 mm) compared with short locking-taper implants supporting single crowns in posterior areas: A 5-year retrospective study
    Lombardo, Giorgio
    Signoriello, Annarita
    Marincola, Mauro
    Liboni, Pietro
    Bonfante, Estevam A.
    Nocini, Pier F.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (06) : 904 - 919
  • [5] DIGITAL TELESCOPIC DENTURE- A VIABLE TREATMENT MODALITY OF PREVENTIVE PROSTHODONTICS: CLINICAL REPORT
    Maiti, Subhabrata
    Rai, Nitesh
    Appanna, Ponnanna
    Jessy, P.
    [J]. ANNALS OF DENTAL SPECIALTY, 2022, 10 (04): : 1 - 4
  • [6] ESTHETIC REHABILITATION WITH RAPID MAXILLARY EXPANSION, LEFORT OSTEOTOMY, AND GINGIVAL VENEER PROSTHESIS: A CASE REPORT
    Maiti, Subhabrata
    Ponnanna, A. A.
    Jingade, Ranganatha Rao K.
    Jessy, P.
    [J]. ANNALS OF DENTAL SPECIALTY, 2022, 10 (04): : 29 - 33
  • [7] Oshida Y., 2022, MED DENT
  • [8] Perrot A., 2019, 3D Printing of Concrete: State of the Art and Challenges of the Digital Construction Revolution, DOI [10.1002/art.10542, DOI 10.1002/ART.10542]
  • [9] Piermatti Jack, 2007, J Oral Implantol, V33, P23, DOI 10.1563/0-831.1
  • [10] Three-dimensional-printed malo bridge: Digital Fixed prosthesis for the partially edentulous maxilla
    Ponnanna, A. A.
    Maiti, Subhabrata
    Rai, Nitesh
    Jessy, P.
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2021, 12 (04) : 451 - 453