Glucose Oxidase Captured into Electropolymerized p-Coumaric Acid towards the Development of a Glucose Biosensor

被引:6
作者
Valdes-Ramirez, Gabriela [1 ]
Galicia, Laura [1 ]
机构
[1] Univ Autonoma Metropolitana Unidad Iztapalapa UAM, Chem Dept, Ave San Rafael Atlixco 186,Leyes Reforma 1ra Secc, Mexico City 09340, DF, Mexico
关键词
p-coumaric acid; electropolymerization; cyclic voltammetry; glucose biosensor; amperometry; permselective membrane; commercial beverages; NONCONDUCTING POLYMERS; ELECTRODES; SENSOR; IMMOBILIZATION; ENZYMES; AREA;
D O I
10.3390/chemosensors11060345
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical biosensor based on the immobilization of glucose oxidase into an electropolymerized p-coumaric acid membrane on a Pt electrode has been developed and evaluated for glucose detection in the range of 1 to 30 mM. The glucose biosensor exhibits a sensitivity of 36.96 mA/mMcm(2), a LOD of 0.66 mM, and a LOQ of 2.18 mM. The biosensing membrane was electropolymerized by cyclic voltammetry in 100 mM phosphates pH 7.00 and 3% ethanol containing glucose oxidase and p-coumaric acid. The glucose biosensors' stability, repeatability, reproducibility, and selectivity were estimated. The biosensing membrane shows permselective properties and antifouling effects. The applicability of the developed glucose biosensor was evaluated in the presence of 20 mg/mL proteins, and any signal associated with biofouling was observed. The glucose biosensors were employed for the determination of the glucose concentration in three commercial beverages.
引用
收藏
页数:13
相关论文
共 46 条
[31]   Synthesis and characterization of wearable cuprous oxide/conductive fabric enabled non-enzymatic electrochemical sensing of glucose [J].
Singh, Anoop ;
Sharma, Asha ;
Sundramoorthy, Ashok K. ;
Arya, Sandeep .
IONICS, 2023, 29 (06) :2501-2513
[32]   The steady-state current at microcylinder electrodes modified by enzymes immobilized in conducting or non-conducting material [J].
Somasundrum, M ;
Aoki, K .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 530 (1-2) :40-46
[33]   Functional Polymers Structures for (Bio)Sensing Application-A Review [J].
Spychalska, Kamila ;
Zajac, Dorota ;
Baluta, Sylwia ;
Halicka, Kinga ;
Cabaj, Joanna .
POLYMERS, 2020, 12 (05)
[34]   Polymers of phenylenediamines [J].
Stejskal, Jaroslav .
PROGRESS IN POLYMER SCIENCE, 2015, 41 :1-31
[35]   IDF Diabetes Atlas: Global, regional and country-level diabetes prevalence estimates for 2021 and projections for 2045 [J].
Sun, Hong ;
Saeedi, Pouya ;
Karuranga, Suvi ;
Pinkepank, Moritz ;
Ogurtsova, Katherine ;
Duncan, Bruce B. ;
Stein, Caroline ;
Basit, Abdul ;
Chan, Juliana C. N. ;
Mbanya, Jean Claude ;
Pavkov, Meda E. ;
Ramachandaran, Ambady ;
Wild, Sarah H. ;
James, Steven ;
Herman, William H. H. ;
Zhang, Ping ;
Bommer, Christian ;
Kuo, Shihchen ;
Boyko, Edward J. J. ;
Magliano, Dianna J. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2022, 183
[36]   Fabricating a new immobilization matrix based on a conjugated polymer and application as a glucose biosensor [J].
Tan, Burcu ;
Baycan, Fatma .
JOURNAL OF APPLIED POLYMER SCIENCE, 2023, 140 (01)
[37]   Applications of polymers for biomolecule immobilization in electrochemical biosensors [J].
Teles, F. R. R. ;
Fonseca, L. R. .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (08) :1530-1543
[38]   Direct and selective determination of p-coumaric acid in food samples via layered Nb4AlC3-MAX phase [J].
Tumay, Sureyya Oguz ;
Sanko, Vildan ;
Senocak, Ahmet ;
Orooji, Yasin ;
Demirbas, Erhan ;
Yoon, Yeojoon ;
Khataee, Alireza .
FOOD CHEMISTRY, 2023, 403
[39]   A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration [J].
Updike, SJ ;
Shults, MC ;
Gilligan, BJ ;
Rhodes, RK .
DIABETES CARE, 2000, 23 (02) :208-214
[40]   Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor [J].
Valdes-Ramirez, Gabriela ;
Galicia, Laura .
MOLECULES, 2021, 26 (12)