Long-Term Valve Durability in Patients Undergoing Transcatheter Aortic Valve

被引:8
|
作者
Stehli, Julia [1 ,2 ,3 ]
Dagan, Misha [1 ]
Duffy, Stephen J. [1 ,4 ,5 ]
Morisset, Stephane [6 ]
Vriesendorp, Pieter [1 ]
Nanayakkara, Shane [1 ,4 ,5 ]
Koh, Ji Quan Samuel [1 ]
Quine, Edward [1 ]
Htun, Nay M. [1 ]
Stub, Dion [1 ,4 ,5 ]
Dick, Ron [2 ]
Walton, Antony S. [1 ,2 ,7 ]
机构
[1] Alfred Hosp, Dept Cardiol, Melbourne, Vic, Australia
[2] Cardiovasc Inst, Epworth Healthcare, Melbourne, Vic, Australia
[3] Monash Univ, Monash Cardiovasc Res Ctr, Sch Clin Sci Monash Hlth, Melbourne, Vic, Australia
[4] Monash Univ, Ctr Cardiovasc Res & Educ Therapeut, Dept Epidemiol & Prevent Med, Melbourne, Vic, Australia
[5] Baker IDI Heart & Diabet Inst, Melbourne, Vic, Australia
[6] Stat Consultancy, Perouges, France
[7] Alfred Hosp, Dept Cardiol, 55 Commercial Rd, Melbourne, Vic 3004, Australia
来源
HEART LUNG AND CIRCULATION | 2023年 / 32卷 / 02期
基金
英国医学研究理事会;
关键词
Transcatheter aortic valve implantation; Degenerative valve; Elderly; Aortic stenosis; Valve restenosis; DETERIORATION; IMPLANTATION; REPLACEMENT; IMPACT;
D O I
10.1016/j.hlc.2022.10.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate the long-term incidence of structural valve deterioration (SVD) in patients who underwent transcatheter aortic valve implantation (TAVI).Method and Results Between 2008 and 2018, 693 underwent TAVI at two centres. Four hundred and twenty-one (421) patients (mean age 83.666.0 yrs) survived for >2 years post TAVI and had at least two consecutive transthoracic echocardiographies (TTEs) with the latest TTE no less than 2 years after TAVI, and were therefore included in the analysis for SVD. Median follow-up was 4.7 (3.6-6.0) years and median echocardiography follow-up 3 (3.0-4.0) years. All-cause mortality was 30.9% (130) with a median time to death of 4.1 (3.0-5.6) years. The cumulative incidence of SVD increased from 1.7% (95% CI, 0.4-2.9) at 3 years to 3.5% (95% CI, 1.5-5.8) at 5 years and 4.7% (95% CI, 1.6-7.9) at 10 years. The overall median time to SVD was 3 (2-4) years. Twelve (12) patients demonstrated SVD stage 2, and 1 patient stage 3. No SVD required re-intervention. All other patients showed no significant changes in valve parameters over time.Conclusions Structural valve deterioration is an uncommon event, occurring in 5% over a total follow-up of 10 years. Most patients show stable valve parameters. However, the analysis is limited by the loss of follow-up (owing to patient mortality), which renders extrapolation of the data to a younger patient population difficult.
引用
收藏
页码:240 / 246
页数:7
相关论文
共 50 条
  • [41] The First Two Cases of Long-Term Outcomes After Transcatheter Aortic Valve Replacement in Patients With Quadricuspid Aortic Valve
    Zhou, Dao
    Fan, Jiaqi
    Liu, Xianbao
    Wang, Jian'an
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (10): : E839 - E840
  • [42] Long-Term Outcome of Patients With Moderate and Severe Prosthetic Aortic Valve Regurgitation After Transcatheter Aortic Valve Implantation
    Gotzmann, Michael
    Korten, Michael
    Bojara, Waldemar
    Lindstaedt, Michael
    Rahlmann, Pia
    Muegge, Andreas
    Ewers, Aydan
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (10): : 1500 - 1506
  • [43] Long-Term Outcomes of Veteran Patients After Transcatheter Aortic Valve Replacement
    Jneid, Hani
    Farmer, Douglas
    Kherallah, Riyad Y.
    Paniagua, David
    Denktas, Ali
    Kar, Biswajit
    Cornwell, Lorraine
    Blaustein, Alvin
    Preventza, Ourania
    Jimenez, Ernesto
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (09): : E730 - E737
  • [44] Long-Term Durability of Bicuspid Aortic Valve Repair DISCUSSION
    不详
    ANNALS OF THORACIC SURGERY, 2014, 97 (05): : 1548 - 1548
  • [45] Long-term outcome after transcatheter aortic valve implantation
    Bouleti, Claire
    Himbert, Dominique
    Iung, Bernard
    Alos, Benjamin
    Kerneis, Caroline
    Ghodbane, Walid
    Messika-Zeitoun, David
    Brochet, Eric
    Fassa, Amir-Ali
    Depoix, Jean-Pol
    Ou, Phalla
    Nataf, Patrick
    Vahanian, Alec
    HEART, 2015, 101 (12) : 936 - 942
  • [46] Long-Term Results Following Transcatheter Aortic Valve Implantation
    Codner, Pablo
    Assali, Abid
    Vaknin-Assa, Hana
    Shapira, Yaron
    Greenberg, Gabriel
    Orvin, Katia
    Perl, Leor
    Kupershmidt, Marina
    Bental, Tamir
    Sagie, Alexander
    Kornowski, Ran
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B221 - B221
  • [47] IMPACT OF AORTIC VALVE CALCIFICATION IN PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE IMPLANTATION
    Stathogiannis, Konstantinos
    Toutouzas, Konstantinos
    Drakopoulou, Maria
    Latsios, George
    Synetos, Andreas
    Xanthopoulou, Maria
    Penesopoulou, Vasiliki
    Oikonomou, George
    Soulaidopoulos, Stergios
    Trantalis, George
    Tousoulis, Dimitris
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1334 - 1334
  • [48] Baseline Atrial Fibrillation in Patients Undergoing Transcatheter Aortic Valve Replacement is Associated With Poor Long-Term Outcome
    Barbash, Israel
    Minha, Sa'ar
    Magalhaes, Marco
    Ben-Dor, Itsik
    Bond, Elizabeth
    Badr, Salem
    Loh, Joshua
    Okubaozi, Petros
    Torguson, Rebecca
    Chan, Fang
    Kitabata, Hironori
    Pendyala, Lakshmana
    Omar, Alfazir
    Ota, Hideaki
    Kent, Kenneth
    Suddath, William
    Satler, Lowell
    Pichard, Augusto
    Waksman, Ron
    CIRCULATION, 2013, 128 (22)
  • [49] LONG TERM DURABILITY OF TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR): A SYSTEMATIC REVIEW OF 5-YEAR VALVE DURABILITY AND BEYOND
    Marashly, Qussay
    Al Danaf, Jad
    Ibrahim, Homam
    Welt, Frederick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1486 - 1486
  • [50] Valve durability after transcatheter aortic valve implantation
    Kataruka, Akash
    Otto, Catherine M.
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S3629 - S3636