Comparison of Sampling Devices for Endocervical Curetting

被引:0
|
作者
Adepiti, Clement Akinfolarin [1 ]
Ajenifuja, Kayode Olusegun [1 ]
机构
[1] Obafemi Awolowo Univ Teaching Hosp Complex, Ife, Osun State, Nigeria
关键词
Colposcopy; Endocervix; Curette; Brush; Precancer; ACCURACY; BRUSH;
D O I
10.1007/s13224-023-01758-8
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
IntroductionEndocervical curetting (ECC) is mandatory when colposcopy is inadequate or when the Pap smear suggests glandular lesion. When the curette is used, ECC is painful; this necessitated the development of the endocervical brush. There is no consensus on which device yields more sample, detects true cervical precancer (CIN2+) better or highlights the effects of age and parity on ECC yield.ObjectiveTo compare ECC yield and the ability to pick up CIN2+ by the different devices and effect of parity and age on yield.MethodThree hundred women referred for colposcopy following positive cervical high-risk HPV DNA test who had inadequate colposcopic examination were randomly allocated to curette, brush and curette and brush groups for ECC. All samples were sent for histology, and the results were compared.ResultOf the 300 women, 103, 100 and 97 had ECC with curette, brush and curette and brush, respectively. Samples were adequate in 92 (89.3%) of the curette, 69 (69.0%) of the brush and 78 (80.4%) of the curette and brush groups. The curette and curette and brush yielded more samples (p = 0.00) and (p = 0.04), respectively, compared with the brush, but there was no difference in yield between curette and curette and brush (p = 0.06). However, there was no difference in the yield of CIN2+ between the sampling devices. Age and parity had no effect on the sample adequacy by the different devices.ConclusionCurette and the curette and brush yielded more samples compared with the brush alone. However, CIN2+ pick-up was similar across all sampling devices.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [41] A Multi-institutional Comparison of Adrenal Venous Sampling in Patients with Primary Aldosteronism: Caution Advised if Successful Bilateral Adrenal Vein Sampling is Not Achieved
    Wang, Tracy S.
    Kline, Greg
    Yen, Tina W.
    Yin, Ziyan
    Liu, Ying
    Rilling, William
    So, Benny
    Findling, James W.
    Evans, Douglas B.
    Pasieka, Janice L.
    WORLD JOURNAL OF SURGERY, 2018, 42 (02) : 466 - 472
  • [42] A Comparison of Sampling Designs for Monitoring Recreational Trail Impacts in Rocky Mountain National Park
    Pettebone, David
    Newman, Peter
    Theobald, David
    ENVIRONMENTAL MANAGEMENT, 2009, 43 (03) : 523 - 532
  • [43] Comparison of two home sleep testing devices with different strategies for diagnosis of OSA
    Gumb, Tyler
    Twumasi, Akosua
    Alimokhtari, Shahnaz
    Perez, Alan
    Black, Kathleen
    Rapoport, David M.
    Sunderram, Jag
    Ayappa, Indu
    SLEEP AND BREATHING, 2018, 22 (01) : 139 - 147
  • [44] Comparison of refractive outcomes using five devices for the assessment of preoperative corneal power
    Whang, Woong-Joo
    Byun, Yong-Soo
    Joo, Choun-Ki
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (05) : 425 - 432
  • [45] Comparison among four immobilization devices for whole breast irradiation with Helical Tomotherapy
    Biston, Marie-Claude
    Jarril, Jimmy
    Dupuis, Pauline
    Boisbouvier, Sophie
    Gassa, Frederic
    Cervellera, Mathilde
    Chabaud, Sylvie
    Racadot, Severine
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 : 205 - 211
  • [46] Intraocular lens power calculation: Clinical comparison of 2 optical biometry devices
    Rabsilber, Tanja M.
    Jepsen, Charlotte
    Auffarth, Gerd U.
    Holzer, Mike P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02) : 230 - 234
  • [47] The comparison of two glucose measurement systems: POCT devices versus central laboratory
    Baygutalp, Nurcan Kilic
    Bakan, Ebubekir
    Bayraktutan, Zafer
    Umudum, Fatma Zuhal
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2018, 43 (05): : 510 - 519
  • [48] Comparison of ocular parameters of two biometric measurement devices in highly myopic eyes
    Guo, Xiao-Xiao
    You, Ran
    Li, Shan-Shan
    Yang, Xiu-Fen
    Zhao, Lu
    Zhang, Fan
    Wang, Yan-Ling
    Chen, Xi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (10) : 1548 - 1554
  • [49] Retrospective comparison of liver chemical shift-encoded PDFF sampling strategies in children and adolescents
    Alves, Vinicius de Padua V.
    Dillman, Jonathan R.
    Trout, Andrew T.
    ABDOMINAL RADIOLOGY, 2022, 47 (10) : 3478 - 3484
  • [50] Comparison of Aerial Surveys and Pellet-Based Distance Sampling Methods for Estimating Deer Density
    Urbanek, Rachael E.
    Nielsen, Clayton K.
    Preuss, Timothy S.
    Glowacki, Gary A.
    WILDLIFE SOCIETY BULLETIN, 2012, 36 (01): : 100 - 106