IntroductionEndocervical curetting (ECC) is mandatory when colposcopy is inadequate or when the Pap smear suggests glandular lesion. When the curette is used, ECC is painful; this necessitated the development of the endocervical brush. There is no consensus on which device yields more sample, detects true cervical precancer (CIN2+) better or highlights the effects of age and parity on ECC yield.ObjectiveTo compare ECC yield and the ability to pick up CIN2+ by the different devices and effect of parity and age on yield.MethodThree hundred women referred for colposcopy following positive cervical high-risk HPV DNA test who had inadequate colposcopic examination were randomly allocated to curette, brush and curette and brush groups for ECC. All samples were sent for histology, and the results were compared.ResultOf the 300 women, 103, 100 and 97 had ECC with curette, brush and curette and brush, respectively. Samples were adequate in 92 (89.3%) of the curette, 69 (69.0%) of the brush and 78 (80.4%) of the curette and brush groups. The curette and curette and brush yielded more samples (p = 0.00) and (p = 0.04), respectively, compared with the brush, but there was no difference in yield between curette and curette and brush (p = 0.06). However, there was no difference in the yield of CIN2+ between the sampling devices. Age and parity had no effect on the sample adequacy by the different devices.ConclusionCurette and the curette and brush yielded more samples compared with the brush alone. However, CIN2+ pick-up was similar across all sampling devices.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [31] Comparison of Corneal Powers Obtained from 4 Different Devices
    Shirayama, Mariko
    Wang, Li
    Weikert, Mitchell P.
    Koch, Douglas D.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (04) : 528 - 535
  • [32] Comparison of two optical biometric devices for intraocular lens calculation
    Uckmann, M. -S.
    Stattin, M.
    Zehetner, C.
    Neururer, S.
    Speicher, L.
    OPHTHALMOLOGE, 2019, 116 (03): : 253 - 260
  • [33] Comparison between professional sampling and self-sampling for HPV-based cervical cancer screening among postmenopausal women
    Bergengren, Lovisa
    Kaliff, Malin
    Larsson, Gabriella L.
    Karlsson, Mats G.
    Helenius, Gisela
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2018, 142 (03) : 359 - 364
  • [34] Effects of Measuring Devices and Sampling Strategies on the Interpretation of Monitoring Data for Long-Term Trend Analysis
    Fischer, Philipp
    Dietrich, Peter
    Achterberg, Eric P.
    Anselm, Norbert
    Brix, Holger
    Bussmann, Ingeborg
    Eickelmann, Laura
    Floeser, Goetz
    Friedrich, Madlen
    Rust, Hendrik
    Schuetze, Claudia
    Koedel, Uta
    FRONTIERS IN MARINE SCIENCE, 2021, 8
  • [35] Comparison of the success of histopathological diagnosis with dilatation-curettage and Pipelle endometrial sampling
    Kazandi, M.
    Okmen, F.
    Ergenoglu, A. M.
    Yeniel, A. O.
    Zeybek, B.
    Zekioglu, O.
    Ozdemir, N.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2012, 32 (08) : 790 - 794
  • [36] Comparison of the ocular ultrasonic and optical biometry devices in the different quality measurements
    Khorrami-Nejad, Masoud
    Khodair, Ahmed Mohammed
    Khodaparast, Mehdi
    Mofrad, Farshid Babapour
    Nasrabadi, Farzaneh Dehghanian
    JOURNAL OF OPTOMETRY, 2023, 16 (04) : 284 - 295
  • [37] Comparison of validation protocols for blood pressure measuring devices in children and adolescents
    Stabouli, Stella
    Chainoglou, Athanasia
    Evripidou, Kleo
    Simao, Carla
    Antza, Christina
    Petrou, Panagiotis
    Hamdani, Gilad
    Calpe, Javier
    Lurbe, Empar
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [38] Comparison of different devices for predicting the lean meat percentage of pig carcasses
    Font i Furnols, Maria
    Gispert, Marina
    MEAT SCIENCE, 2009, 83 (03) : 443 - 446
  • [39] Comparison of Injection Molding Technologies for the Production of Micro-Optical Devices
    Sortino, Marco
    Totis, Giovanni
    Kuljanic, Elso
    24TH DAAAM INTERNATIONAL SYMPOSIUM ON INTELLIGENT MANUFACTURING AND AUTOMATION, 2013, 2014, 69 : 1296 - 1305
  • [40] Comparison of two optical devices used for artificial tooth color selection
    Smielecka, Malgorzata
    Dorocka-Bobkowska, Barbara
    DENTAL AND MEDICAL PROBLEMS, 2022, 59 (02) : 249 - 253