Modified Hybrid PSO Algorithm for Efficient Control of the Matrix Converter-Fed Electrical Drive System

被引:2
作者
Amarendra, Ch. [1 ]
Pandian, A. [2 ]
Reddy, Ch. Rami [3 ]
Kalyan, Ch. Naga Sai [4 ]
Bajaj, Mohit [5 ,6 ,7 ]
AboRas, Kareem M. [8 ]
Wapet, Daniel Eutyche Mbadjoun [9 ]
机构
[1] Aditya Engn Coll, Elect & Elect Engn, Surampalem, India
[2] Koneru Lakshmaiah Educ Fdn, Elect & Elect Engn, Guntur, India
[3] Joginpally BR Engn Coll, Elect & Elect Engn, Hyderabad, India
[4] Vasireddy Venkatadri Inst Technol, Elect & Elect Engn, Guntur, India
[5] Graph Era Deemed Univ, Dept Elect Engn, Dehra Dun 248002, India
[6] Graph Era Hill Univ, Dehra Dun 248002, India
[7] Appl Sci Private Univ, Appl Sci Res Ctr, Amman 11931, Jordan
[8] Alexandria Univ, Fac Engn, Dept Elect Power & Machines, Alexandria, Egypt
[9] Univ Yaounde I, Natl Adv Sch Engn Yaounde, Lab Elect Engn Mechatron & Signal Treatment, Yaounde, Cameroon
关键词
Compilation and indexing terms; Copyright 2025 Elsevier Inc;
D O I
10.1155/2023/4344270
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Advanced power converters are being developed due to the latest developments in power electronics switches. The matrix converter (MC) assessment is the product of this drastic growth. MC is a bidirectional power flow device with a single-step energy conversion mechanism that operates at variable voltage and frequency. The main drawback of MC is the presence of harmonics due to power electronic device switching. A lot of research has been done to decrease the harmonics content present in the MC, but it is restricted to a certain level only. To overcome this limit, the harmonics are minimized in the MC by incorporating soft computing controllers. This article presents particle swarm optimization (PSO), modified PSO (MPSO), and modified hybrid PSO (MHPSO) based controllers for different loads. The proposed MC with a soft computing controller reduces the harmonics by selecting suitable switching pulses for every sample. The simulations are made using the MATLAB/Simulink environment. The results of the proposed MHPSO controller reduce the THD value from 8.654 with a PSO approach to 7.536 in the presence of nonlinear loads.
引用
收藏
页数:13
相关论文
共 34 条
  • [1] AlirezaJahangiri, 2011, EUR C POW ELECT APPL
  • [2] Ansari S, 2017, 2017 4TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ELECTRONICS (UPCON), P9, DOI 10.1109/UPCON.2017.8251014
  • [3] Preselection algorithm based on predictive control for direct matrix converter
    Dan, Hanbing
    Zhu, Qi
    Peng, Tao
    Yao, Sun
    Wheeler, Patrick
    [J]. IET ELECTRIC POWER APPLICATIONS, 2017, 11 (05) : 768 - 775
  • [4] Eberhart J., 1995, P 6 INT S MICR HUM S, P39
  • [5] Comparative analysis of swarm optimization-based control method for direct matrix converter
    Gozde, Haluk
    [J]. ELECTRICAL ENGINEERING, 2015, 97 (03) : 181 - 193
  • [6] Gözde H, 2013, 2013 8TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), P107
  • [7] Hongwu She, 2009, 2009 International Conference on Power Electronics and Drive Systems (PEDS 2009), P672, DOI 10.1109/PEDS.2009.5385684
  • [8] Jose P. S., 2011, 2011 Proceedings of International Conference on Emerging Trends in Electrical and Computer Technology (ICETECT 2011), P386, DOI 10.1109/ICETECT.2011.5760148
  • [9] Laskody T, 2014, APPLIED ELECTRONICS, P181, DOI 10.1109/AE.2014.7011696
  • [10] Single-Phase Soft-Switched AC-AC Matrix Converter With Power Controller for Bidirectional Inductive Power Transfer Systems
    Moghaddami, Masood
    Sarwat, Arif I.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (04) : 3760 - 3770