An In Vitro Study of the Effect of CO2 Laser Power Output on Ablative Properties in Porcine Tongue

被引:0
|
作者
Mungmee, Amontep [1 ,2 ]
Sattayut, Sajee [1 ,2 ]
机构
[1] Khon Kaen Univ, Dept Oral & Maxillofacial Surg, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Lasers Dent Res Grp, Khon Kaen 40002, Thailand
来源
LIFE-BASEL | 2023年 / 13卷 / 01期
关键词
power output; carbon dioxide laser; ablative properties; oral soft tissue; ORAL LEUKOPLAKIA; SOFT-TISSUE; EXCISION; MUCOSA;
D O I
10.3390/life13010162
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
CO2 lasers have been generally used in oral soft-tissue surgery. Although an increase in power enhances the depth of ablation, the specific correlation between units of power and ablative depth has not been stated. This study aimed to explore ablative depth and width affected by a power unit of 10,600-nm CO2 laser continuous wave at 3 to 10 W in tissue blocks of the swine tongue. The 112 samples were randomly allocated into eight groups according to the power settings. The depth and width of the incision were measured by using the ImageJ program. The 3 W group showed the minimal depth of ablation [0.527 mm (0.474 and 0.817)] and width of ablation [0.147 mm (0.110 to 0.184)]. The maximal depth [3.750 mm (3.362 and 4.118)] and width [0.700 mm (0.541 to 0.860)] were in the 9 W group. The correlation between the ablative depth and power unit was 0.81 (p < 0.001). Based on the regression equation (p < 0.001), the ablative depth (mm) = (the power unit of laser in W x 0.491) - 0.731. In conclusion, the ablative depth of the CO2 laser on soft tissue was strongly correlated to power units enabling the prediction equation.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] OUTPUT POWER OF A WAVEGUIDE CO2 LASER.
    Grigor'yants, V.V.
    Kuzyakov, B.A.
    Sinitsyn, A.M.
    Soviet journal of quantum electronics, 1980, 10 (10): : 1213 - 1215
  • [2] Effect of CO2 Ultrapulse Laser Ablative Therapy on Blepharoconjunctival Nevi
    厉建鸣
    戎惠珍
    贾高蓉
    魏根娣
    护理学杂志, 2005, (10) : 34 - 35
  • [3] Ablative CO2 Laser for the Treatment of Pachydermodactyly
    Taibo, A.
    Lopez, O.
    Sanchez, M. Almagro
    del Pozo, J.
    ACTAS DERMO-SIFILIOGRAFICAS, 2024, 115 (05): : T511 - T512
  • [4] EFFECT OF WATER VAPOR ON OUTPUT POWER OF CO2 GAS-DYNAMIC LASER
    SATO, K
    SEKIGUCHI, T
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1973, 35 (01) : 315 - 315
  • [5] Investigation of CO2 laser resonator with maximum output power
    Cheng, Cheng
    Ma, Yangwu
    Jiguang Jishu/Laser Technology, 2002, 26 (05):
  • [7] The Ablation Properties of CO2 Laser Irradiating to Absorption Media: An In Vitro Study
    Sattayut, Sajee
    Hortong, Kittiwut
    Kitichaiwan, Chorpaka
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [8] FRACTIONATED ABLATIVE CO2 LASER FOR THE TREATMENT OF RHINOPHYMA
    Serowka, Kathryn
    Saedi, Nazanin
    Zachary, Christopher
    Dover, Jeffrey
    LASERS IN SURGERY AND MEDICINE, 2013, 45 : 3 - 3
  • [9] Noise, Fluctuations and Output Power Stabilization in a CO2 Laser.
    Michalski, Wojciech
    Nowicki, Romuald
    Plinski, Edward F.
    Elektronika, 1977, 18 (7-8): : 303 - 305
  • [10] CO2 laser induced ablative micropatterns in skin
    Pandolfino, T
    Laubach, HJ
    Gagnon, D
    Manstein, D
    LASERS IN SURGERY AND MEDICINE, 2006, : 82 - 82