Randomized Clinical Trial Comparing Insertion Torque and Implant Stability of Two Different Implant Macrogeometries in the Initial Periods of Osseointegration

被引:12
作者
Gehrke, Sergio Alexandre [1 ,2 ,3 ,4 ]
Cortellari, Guillermo Castro [1 ]
Fernandes, Gustavo Vicentis de Oliveira [5 ]
Scarano, Antonio [1 ,6 ]
Martins, Rafael Garcia [7 ]
Cancado, Renata Moreira [7 ]
Mesquita, Alfredo Mikail Melo [7 ]
机构
[1] UCAM, Dept Res, Bioface PgO, Calle Cuareim 1483, Montevideo 11100, Uruguay
[2] Univ Miguel Hernandez, Inst Bioingn, Avda Ferrocarril S-N, Elche 03202, Spain
[3] Univ Catol Murcia UCAM, Dept Biotechnol, Murcia 30107, Spain
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Mat Engn, BR-90619900 Porto Alegre, Brazil
[5] Univ Michigan, Periodont & Oral Med Dept, Sch Dent, Ann Arbor, MI 48109 USA
[6] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
[7] Paulista Univ UNIP, Dept Implantol, BR-04026002 Sao Paulo, Brazil
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 01期
关键词
clinical study; implant macrogeometry; implant stability; insertion torque; resonance frequency analysis; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; CORTICAL BONE; DESIGN; DIMENSION; CONTACT;
D O I
10.3390/medicina59010168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 +/- 6.41 Ncm for the DC group and 29.3 +/- 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 +/- 3.78 and 69.8 +/- 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 +/- 3.92 and 72.1 +/- 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.
引用
收藏
页数:15
相关论文
共 52 条
  • [11] Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone
    Bilhan, H.
    Geckili, O.
    Mumcu, E.
    Bozdag, E.
    Sunbuloglu, E.
    Kutay, O.
    [J]. JOURNAL OF ORAL REHABILITATION, 2010, 37 (12) : 900 - 907
  • [12] Resonance frequency analysis with two different devices after conventional implant placement with ridge preservation: A prospective pilot cohort study
    Brouwers, Joost E. I. G.
    Buis, Sharon
    de Groot, Philip G.
    de Laat, Bas
    Remijn, Jasper A.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (05) : 789 - 799
  • [13] Evaluation of Adjuvant Systems in Non-Surgical Peri-Implant Treatment: A Literature Review
    Butera, Andrea
    Maiorani, Carolina
    Gallo, Simone
    Pascadopoli, Maurizio
    Venugopal, Adith
    Marya, Anand
    Scribante, Andrea
    [J]. HEALTHCARE, 2022, 10 (05)
  • [14] Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
    Choi, Jung-Yoo
    Sim, Jae-Hyuk
    Yeo, In-Sung Luke
    [J]. JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2017, 47 (03) : 182 - 192
  • [15] Osseointegration of dental implants in Macaca fascicularis
    Dewi, R. S.
    Odang, R. W.
    Odelia, L.
    [J]. 1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [16] Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Cappare, Paolo
    Barbon, Silvia
    Gherlone, Enrico Felice
    [J]. MATERIALS, 2021, 14 (23)
  • [17] Improvement in the Initial Implant Stability Quotient Through Use of a Modified Surgical Technique
    Diaz-Sanchez, Rosa-Maria
    Delgado-Munoz, Jose-Maria
    Hita-Iglesias, Pilar
    Pullen, Kyle T.
    Serrera-Figallo, Maria-Angeles
    Torres-Lagares, Daniel
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (03) : 186 - 193
  • [18] do Vale Souza Joao Paulo, 2021, Eur J Dent, V15, P618, DOI 10.1055/s-0041-1725575
  • [19] Surgical and Nonsurgical Treatment Protocols for Peri-implantitis: An Overview of Systematic Reviews
    dos Santos Martins, Bruno Gomes
    Hasse Fernandes, Juliana Campos
    Martins, Andrea Gomes
    Castilho, Rogerio de Moraes
    de Oliveira Fernandes, Gustavo Vicentis
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 660 - +
  • [20] Ebenezer S., 2021, In oral and maxillofacial surgery for the clinician, P385, DOI [DOI 10.1007/978-981-15-1346-6_18, 10.1007/978-981-15-1346-6_18]