Randomized Clinical Trial Comparing Insertion Torque and Implant Stability of Two Different Implant Macrogeometries in the Initial Periods of Osseointegration

被引:12
作者
Gehrke, Sergio Alexandre [1 ,2 ,3 ,4 ]
Cortellari, Guillermo Castro [1 ]
Fernandes, Gustavo Vicentis de Oliveira [5 ]
Scarano, Antonio [1 ,6 ]
Martins, Rafael Garcia [7 ]
Cancado, Renata Moreira [7 ]
Mesquita, Alfredo Mikail Melo [7 ]
机构
[1] UCAM, Dept Res, Bioface PgO, Calle Cuareim 1483, Montevideo 11100, Uruguay
[2] Univ Miguel Hernandez, Inst Bioingn, Avda Ferrocarril S-N, Elche 03202, Spain
[3] Univ Catol Murcia UCAM, Dept Biotechnol, Murcia 30107, Spain
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Mat Engn, BR-90619900 Porto Alegre, Brazil
[5] Univ Michigan, Periodont & Oral Med Dept, Sch Dent, Ann Arbor, MI 48109 USA
[6] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
[7] Paulista Univ UNIP, Dept Implantol, BR-04026002 Sao Paulo, Brazil
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 01期
关键词
clinical study; implant macrogeometry; implant stability; insertion torque; resonance frequency analysis; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; CORTICAL BONE; DESIGN; DIMENSION; CONTACT;
D O I
10.3390/medicina59010168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 +/- 6.41 Ncm for the DC group and 29.3 +/- 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 +/- 3.78 and 69.8 +/- 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 +/- 3.92 and 72.1 +/- 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.
引用
收藏
页数:15
相关论文
共 52 条
  • [1] Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants
    Acil, Yahya
    Sievers, Jan
    Guelses, Aydin
    Ayna, Mustafa
    Wiltfang, Joerg
    Terheyden, Hendrik
    [J]. ODONTOLOGY, 2017, 105 (03) : 347 - 353
  • [2] Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
    Alexandre Gehrke, Sergio
    Aramburu, Jaime, Jr.
    Eirles Treichel, Tiago Luis
    do Prado, Tales Dias
    Dedavid, Berenice Anina
    de Aza, Piedad N.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [3] Can changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations
    Alexandre Gehrke, Sergio
    Aramburu, Jaime Junior
    Perez-Diaz, Leticia
    do Prado, Tales Dias
    Dedavid, Berenice Anina
    Mazon, Patricia
    De Aza, Piedad N.
    [J]. PLOS ONE, 2020, 15 (05):
  • [4] Primary Stability of Three Different Osteotomy Techniques in Medullary Bone: An in Vitro Study
    Attanasio, Ferdinando
    Antonelli, Alessandro
    Brancaccio, Ylenia
    Averta, Fiorella
    Figliuzzi, Michele Mario
    Fortunato, Leonzio
    Giudice, Amerigo
    [J]. DENTISTRY JOURNAL, 2020, 8 (01)
  • [5] Drilling dimension effects in early stages of osseointegration and implant stability in a canine model
    Baires-Campos, Felipe-Eduardo
    Jimbo, Ryo
    Bonfante, Estevam-Augusto
    Fonseca-Oliveira, Maiolino-Thomaz
    Moura, Camila
    Zanetta-Barbosa, Darceny
    Coelho, Paulo-Guilherme
    [J]. MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2015, 20 (04): : E471 - E479
  • [6] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [7] Bavetta Giuseppe, 2019, Biomed Res Int, V2019, P9720419, DOI 10.1155/2019/9720419
  • [8] Resonance frequency analysis: Comparing two clinical instruments
    Becker, William
    Hujoel, Philippe
    Becker, Burton E.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (03) : 308 - 312
  • [9] Bedrossian Edmond, 2020, Compend Contin Educ Dent, V41, pe1
  • [10] Osseodensification effect on implants primary and secondary stability: Multicenter controlled clinical trial
    Bergamo, Edmara T. P.
    Zahoui, Abbas
    Barrera, Raul Bravo
    Huwais, Salah
    Coelho, Paulo G.
    Karateew, Edward Dwayne
    Bonfante, Estevam A.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (03) : 317 - 328