Usefulness of PET/CT with Carbon-11-Labeled Methionine in the Diagnosis of Tertiary Hyperparathyroidism

被引:4
作者
Kolodziej, Maciej [1 ]
Saracyn, Marek [1 ]
Lubas, Arkadiusz [2 ]
Dziuk, Miroslaw [3 ]
Durma, Adam Daniel [1 ]
Smoszna, Jerzy [2 ]
Zelichowski, Grzegorz [4 ]
Niemczyk, Stanislaw [2 ]
Kaminski, Grzegorz [1 ]
机构
[1] Mil Inst Med, Natl Res Inst, Dept Endocrinol & Isotope Therapy, PL-04141 Warsaw, Poland
[2] Mil Inst Med, Natl Res Inst, Dept Internal Med Nephrol & Dialysis, PL-04141 Warsaw, Poland
[3] Mil Inst Med, Natl Res Inst, Dept Nucl Med, PL-04141 Warsaw, Poland
[4] Wolski Hosp, DaVita Dialysis Unit, PL-01211 Warsaw, Poland
关键词
PET; CT; tertiary hyperparathyroidism; carbon-11; methionine; hyperparathyroidism; C-11-METHIONINE PET/CT; PARATHYROID LOCALIZATION; SCINTIGRAPHY; GUIDELINES; MANAGEMENT; SPECT/CT;
D O I
10.3390/nu15010188
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Introduction: Tertiary hyperparathyroidism (tHP) may develop in patients treated with hemodialysis or peritoneal dialysis. Parathyroidectomy may result in a significant reduction in the severity of symptoms. For the effective surgical treatment of hyperparathyroidism, proper localization of the parathyroid glands prior to surgery is essential. The sensitivity of scintigraphy in the diagnosis of tHP is lower than in the diagnosis of primary hyperparathyroidism. In recent years, positron emission tomography (PET/CT) has been gaining importance, usually as a complementary technique. Aim: The aim of this study was to determine the usefulness of PET/CT with [C-11]MET in the preoperative localization diagnosis of patients with tertiary hyperparathyroidism caused by chronic kidney disease, in whom first-line diagnostic methods did not allow the localization of pathologically parathyroid glands. Material and methods: The study was conducted in a group of 19 adult patients with severe tHP who were resistant or intolerant to non-invasive treatment, with negative results of scintigraphy and ultrasonography of the neck. The study protocol included measurement of the concentration of calcium, phosphorus, and PTH in the blood serum and performing PET/CT with [C-11]MET. Results: A positive result of PET/CT was obtained in 89.5% of the patients (17/19). Parathyroidectomy was performed in 52.9% of the patients (9/17) with positive results of PET/CT with [C-11]MET, which were fully consistent with the results of the histopathological examinations of the removed parathyroid glands. On this basis, the sensitivity of PET/CT with [C-11]MET in the preoperative localization diagnosis of patients with tHP was found to be 100%. Multiple lesions were visualized in 57.9% of the patients (11/19). Ectopic lesions were visualized in 21.1% of the patients (4/19). Conclusions: PET/CT with [C-11]MET is a sensitive technique for the second-line preoperative imaging of parathyroid glands in patients with tertiary hyperparathyroidism in whom first-line examinations, such as ultrasound and scintigraphy, has failed.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Usefulness of 68Ga-Pentixafor PET/CT on Diagnosis and Management of Cushing Syndrome
    Ding, Jie
    Tong, Anli
    Hacker, Marcus
    Feng, Ming
    Huo, Li
    Li, Xiang
    CLINICAL NUCLEAR MEDICINE, 2022, 47 (08) : 669 - 676
  • [42] Usefulness of Combined FDG-PET with CT or Tumour Markers in Lung Cancer Diagnosis
    Kley, Konstantin
    Oehr, Peter
    ANTICANCER RESEARCH, 2010, 30 (05) : 1741 - 1745
  • [43] Combined fluorine-18-FDG and carbon-11-methionine PET for diagnosis of tumors in lung and mediastinum
    Nettelbladt, OS
    Sundin, AE
    Valind, SO
    Gustafsson, GR
    Lamberg, K
    Långström, B
    Björnsson, EH
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (04) : 640 - 647
  • [44] Evaluation of carbon-11-labeled KF17837:: A potential CNS adenosine A2a receptor ligand
    Noguchi, J
    Ishiwata, K
    Wakabayashi, S
    Nariai, T
    Shumiya, S
    Ishii, S
    Toyama, H
    Endo, K
    Suzuki, F
    Senda, M
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (03) : 498 - 503
  • [45] Value of [ 11 C]-Methionine PET/CT in Preoperative Localization of Parathyroid Adenomas
    Saerens, Julie
    Velkeniers, Brigitte
    Keyaerts, Marleen
    Raeymaeckers, Steven
    Vanhoeij, Marian
    Blotwijk, Susanne
    Bravenboer, Bert
    HORMONE AND METABOLIC RESEARCH, 2021, 53 (07) : 444 - 452
  • [46] Dural MALT Lymphoma Detected by 11C-Methionine PET/CT
    Annunziata, Salvatore
    Cuccaro, Annarosa
    Caldarella, Carmelo
    Hohaus, Stefan
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (12) : 962 - 963
  • [47] Utility of 11C-methionine PET/CT in neuro-oncology
    Casas Parera, Ignacio
    Igirio Gamero, Jorge L.
    Blumenkrantz, Yamila
    Bruno, Gabriel
    Baez, Alejandra
    Tafur Canabal, Jose G.
    Baez, Mariana
    Kuchkaryan, Valeria
    MEDICINA-BUENOS AIRES, 2013, 73 (03) : 201 - 206
  • [48] Usefulness of 11C-methionine-PET for predicting the efficacy of carbon ion radiation therapy for head and neck mucosal malignant melanoma
    Hasebe, M.
    Yoshikawa, K.
    Nishli, R.
    Kawaguchi, K.
    Kamada, T.
    Hamada, Y.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (10) : 1220 - 1228
  • [49] Usefulness of PET/CT for diagnosis of periosteal chondrosarcoma of the femur: A case report
    Morimoto, Shota
    Futani, Hiroyuki
    Tsuchiyama, Konan
    Fukunaga, Satoru
    Tsukamoto, Yoshitane
    Yoshiya, Shinichi
    ONCOLOGY LETTERS, 2014, 7 (06) : 1826 - 1828
  • [50] 11C-Acetate PET/CT for Reactive Astrogliosis Outperforms 11C-Methionine PET/CT in Glioma Classification and Survival Prediction
    Kim, Dongwoo
    Yi, Ju Hyeon
    Park, Youngjoo
    Kim, Sun Jung
    Kang, Seok-Gu
    Kim, Se Hoon
    Chun, Joong-Hyun
    Chang, Jong Hee
    Yun, Mijin
    CLINICAL NUCLEAR MEDICINE, 2024, 49 (02) : 109 - 115