As loud as a construction site: Noise levels in the emergency department

被引:4
作者
Adams, Corey [1 ,3 ]
Walsan, Ramya [1 ]
Mcdonnell, Rebecca [1 ]
Schembri, Anthony [2 ]
机构
[1] Macquarie Univ, Australian Inst Hlth Innovat AIHI, 75 Talavera Rd, Sydney, NSW 2113, Australia
[2] St Vincents Hlth Network, 390 Victoria St, Darlinghurst, NSW 2010, Australia
[3] Australian Inst Hlth Innovat, 75 Talavera Rd, N Ryde, NSW 2113, Australia
关键词
Patients; Noise; Environment; Hospitals; Safety; Patient experience; PATIENT EXPERIENCE; CARE;
D O I
10.1016/j.auec.2023.07.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The Emergency Department (ED), while being an integral part of healthcare systems, frequently experiences noise levels surpassing the World Health Organization's recommended thresholds. These excessive noise levels could considerably compromise the safety and wellbeing of both patients and staff. Methods: To evaluate noise levels throughout the ED environment, this study utilized dosimeters to measure noise levels over a 24 -hour period in six distinct locations, including the ED Waiting Room and Treatment areas. Results: The study found that noise exceeded the WHO recommendations in all six areas of the ED for the entire 24 -hour period. Peak noise levels were recorded up to 102.8 dB, which is as loud as noise levels at a construction site. The ED Waiting Room exhibited high peak and average noise levels, indicating the urgent need for quality improvement efforts. These findings align with the results of previous research, thereby suggesting that noise levels in the ED have remained problematic for more than a decade. Conclusion: The findings of this study underscore the importance of addressing excessive noise levels in the ED to create a safe and therapeutic hospital environment for both patients and staff. Healthcare organizations must implement proactive measures to address excessive noise levels in the ED. (c) 2023 The Authors. Published by Elsevier Ltd on behalf of College of Emergency Nursing Australasia. This is an open access article under the CC BY -NC -ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:26 / 29
页数:4
相关论文
共 17 条
[1]  
Bureau of Health Information, Data Portal 2023
[2]   Noise levels in Johns Hopkins Hospital [J].
Busch-Vishniac, IJ ;
West, JE ;
Barnhill, C ;
Hunter, T ;
Orellana, D ;
Chivukula, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 118 (06) :3629-3645
[3]   MRI acoustic noise: Sound pressure and frequency analysis [J].
Counter, SA ;
Olofsson, A ;
Grahn, HF ;
Borg, E .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :606-611
[4]   Mapping sources of noise in an intensive care unit [J].
Darbyshire, J. L. ;
Mueller-Trapet, M. ;
Cheer, J. ;
Fazi, F. M. ;
Young, J. D. .
ANAESTHESIA, 2019, 74 (08) :1018-1025
[5]   The signal is clear: It's noisy in the emergency department [J].
Fatovich, Daniel M. .
EMERGENCY MEDICINE AUSTRALASIA, 2020, 32 (02) :354-356
[6]   Ambient Noise in Emergency Rooms and Its Health Hazards [J].
Filus, Walderes ;
Moreira de lacerda, Adriana Bender ;
Albizu, Evelyn .
INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2015, 19 (03) :205-209
[7]   Emergency department noise: mental activation or mental stress? [J].
Folscher, Lindy-Lee ;
Goldstein, Lara Nicole ;
Wells, Mike ;
Rees, David .
EMERGENCY MEDICINE JOURNAL, 2015, 32 (06) :468-473
[8]   'They do not care how much you know until they know how much you care': a qualitative metasynthesis of patient experience in the emergency department [J].
Graham, Blair ;
Endacott, Ruth ;
Smith, Jason E. ;
Latour, Jos M. .
EMERGENCY MEDICINE JOURNAL, 2019, 36 (06) :355-+
[9]   Incubator-based Sound Attenuation: Active Noise Control In A Simulated Clinical Environment [J].
Hutchinson, George ;
Du, Lilin ;
Ahmad, Kaashif .
PLOS ONE, 2020, 15 (07)
[10]  
Jue Katie, 2019, Proceedings of the Human Factors and Ergonomics Society Annual Meeting, V63, P1510, DOI 10.1177/1071181319631325