A reliability-based construction approach for wide-area backup protection systems utilizing phasor measurement units in smart grids

被引:0
|
作者
Jia, Huibin [1 ,3 ]
Hou, Weiran [1 ]
Zheng, Tao [2 ]
Wan, Siqi [1 ]
Gai, Yonghe [1 ]
机构
[1] North China Elect Power Univ, Dept Elect & Commun Engn, Baoding, Peoples R China
[2] North China Elect Power Univ, Sch Elect & Elect Engn, Baoding, Peoples R China
[3] Mailbox 22,619 Yonghua St, Baoding, Hebei, Peoples R China
关键词
optimisation; phasor measurement; reliability; smart power grids; wide area networks; PLACEMENT; NETWORK;
D O I
10.1049/gtd2.13122
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Reliability is a fundamental requirement of wide-area backup protection (WABP) systems, and it is one of the most crucial performance indicators for such a WABP system. Two definitions are introduced: the reliability of WABP systems and the undetectable probability of a power line. They are determined by the specific placement of communication links (CLs) and phasor measurement units (PMUs). A simultaneous optimization model was developed to minimize the construction cost of WABP systems by optimizing the partitioning and placement of PMUs, protection centers, and CLs. The model considers several constraints, including latency, regional balance, and system reliability. To reduce the computational complexity, a cluster-based genetic algorithm was developed to determine the optimal solution. Finally, numerical simulations were conducted using IEEE test cases. The results demonstrate that the proposed method can minimize the construction costs of WABP systems while increasing their reliability. This paper analyzes the impact of phasor measurement unit communication link failure on wide-area backup protection system (WABP) reliability. Then, a reliability-based construction approach of WABP system that minimizes construction cost is proposed. image
引用
收藏
页码:1059 / 1071
页数:13
相关论文
共 50 条
  • [21] Wide-Area Backup Protection Algorithm Based on Fault Component Voltage Distribution
    He, Zhiqin
    Zhang, Zhe
    Chen, Wei
    Malik, Om P.
    Yin, Xianggen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2752 - 2760
  • [22] A Survey on the Application of Phasor Measurement Units to the Protection of Transmission and Smart Distribution Systems
    Menezes, T. S.
    Barra, P. H. A.
    Dizioli, F. A. S.
    Lacerda, V. A.
    Fernandes, R. A. S.
    Coury, D. V.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2024, 52 (08) : 1379 - 1396
  • [23] Research on Wide-Area Backup Automatic Switch System for Smart Substation Based on RTDS
    Lu, Shengyang
    Sui, Xin
    Li, Huan
    Cai, Yupeng
    Wang, Tong
    Zhang, Wuyang
    Liu, Ziqian
    Song, Baoquan
    Dong, Bo
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 895 - 899
  • [24] Fault-Tolerant Placement of Phasor Measurement Units and Communication Infrastructure in SDN-Enabled Wide-Area Monitoring Systems
    Jia, Huibin
    Hou, Weiran
    Wan, Siqi
    Wang, Xuguang
    Xiang, Hongyin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [25] A comprehensive backup protection for transmission lines based on an intelligent wide-area monitoring system
    Petite, Fernanda Soares Vitor
    dos Santos, Ricardo Caneloi
    Junior, Giovanni Manassero
    Yang, Qingqing
    Li, Jianwei
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (05)
  • [26] Phasor Measurement Unit (PMU) Based Wide Area Protection System
    Urooj, Shabana
    Sood, Vani
    2015 2ND INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2015, : 597 - 599
  • [27] Synchrophasor-Based Wide-Area Backup Protection Scheme with Data Requirement Analysis
    Zare, Javad
    Aminifar, Farrokh
    Sanaye-Pasand, Majid
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1410 - 1419
  • [28] Communication-Constrained Regionalization of Power Systems for Synchrophasor-Based Wide-Area Backup Protection Scheme
    Zare, Javad
    Aminifar, Farrokh
    Sanaye-Pasand, Majid
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (03) : 1530 - 1538
  • [29] A Differential Voltage-Based Wide-Area Backup Protection Scheme for Transmission Network
    Samantaray, Shalini Ranjan
    Samantaray, Subhransu Ranjan
    IEEE SYSTEMS JOURNAL, 2022, 16 (01): : 520 - 530
  • [30] A Synchro-phasor Based Wide Area Protection Scheme for Interconnected Power Grids
    Dash, Jitendra Kumar
    Biswal, Bidyadhar
    2016 IEEE 6TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2016,