Can portable air cleaners reconcile conflicting needs for open-door/window autonomy and indoor air quality for occupants in densely populated offices?

被引:3
作者
Li, Yiqun [1 ]
Fan, Yujie [2 ]
Wei, Yuan [1 ]
Liu, Mingqi [1 ]
Xu, Bin [3 ]
Ye, Wei [1 ,4 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai 201804, Peoples R China
[2] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[3] Tongji Univ, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[4] Tongji Univ, Key Lab Performance Evolut & Control Engn Struct, Minist Educ, Shanghai 200092, Peoples R China
关键词
Portable air cleaner; Mechanical ventilation; Indoor air quality; Randomized; Single-blind trial; Open office; MECHANICAL VENTILATION; PERFORMANCE; RESPONSES; ENERGY; IMPACT;
D O I
10.1016/j.apenergy.2023.122548
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Conventional wisdom advises keeping windows and doors closed in air-conditioned or mechanically-ventilated space. However, this guideline often proves challenging in high-occupancy offices, where the constant influx and egress of individuals, coupled with a strong inclination toward open windows, trigger occupant-induced ventilation (OV) that can affect indoor air quality (IAQ) and energy consumption. To address this, we explored using portable air cleaners (PACs) as a cost-effective ventilation strategy to replace mechanical ventilation (MV) while maintaining IAQ and respecting occupant freedom. We conducted a single-blind trial in a 100 m(2) office in Shanghai from December 2020 to March 2021, measuring 857 h of indoor and outdoor temperatures, CO2 and PM2.5 concentrations, and occupant behaviors. We obtained 618 valid subjective responses and conducted a 14-day test to measure possible by-products, such as O-3, formaldehyde, and VOCs, during the operation of PACs. The results showed that, first, although MV achieved 2-3 times higher air change rates than PACs, indoor CO2 concentrations remained below 1000 ppm, the commonly accepted threshold, using PACs in the presence of OV. Second, PACs effectively reduced PM(2.5 )levels during outdoor PM2.5 peaks. Third, occupants' perceived IAQ did not differ between the use of PACs and MV (p>0.05), although individuals with PACs in the afternoon reported slightly increased sleepiness (p<0.05). Fourth, in the presence of OV, PACs demonstrated significant energy-saving potential in improving IAQ. Our study showed PACs can be a cost-effective method to replace MV while maintaining IAQ and preserving occupant freedom.
引用
收藏
页数:14
相关论文
共 41 条
  • [11] Modelling of sorbent-based gas filters for indoor environment: A comprehensive review
    Khararoodi, Mohamad Ghamangiz
    Lee, Chang-Seo
    Haghighat, Fariborz
    [J]. BUILDING AND ENVIRONMENT, 2022, 208
  • [12] Can increased outdoor CO2 concentrations impact on the ventilation and energy in buildings? A case study in Shanghai, China
    Kim, Moon Keun
    Choi, Joon-Ho
    [J]. ATMOSPHERIC ENVIRONMENT, 2019, 210 : 220 - 230
  • [13] Tracking the human-building interaction: A longitudinal field study of occupant behavior in air-conditioned offices
    Langevin, Jared
    Gurian, Patrick L.
    Wen, Jin
    [J]. JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 2015, 42 : 94 - 115
  • [14] Multi-objective optimization of mechanical ventilation with the aid of purifiers in two scenarios: Regular operation and mitigating the spread of respiratory infectious diseases
    Li, Yiqun
    Fan, Yujie
    Zhi, Chengqiang
    Ye, Wei
    Zhang, Xu
    [J]. BUILDING SIMULATION, 2023, 16 (05) : 795 - 811
  • [15] A comparative field study of indoor environmental quality in two types of open-plan offices: Open-plan administrative offices and open-plan research offices
    Lou, Huading
    Ou, Dayi
    [J]. BUILDING AND ENVIRONMENT, 2019, 148 : 394 - 404
  • [16] Determining Building Natural Ventilation Potential via IoT-Based Air Quality Sensors
    Luo, Maohui
    Hong, Yumeng
    Pantelic, Jovan
    [J]. FRONTIERS IN ENVIRONMENTAL SCIENCE, 2021, 9
  • [17] A window of one's own: a public office post-occupancy evaluation
    Meir, Isaac A.
    Schwartz, Moshe
    Davara, Yosefa
    Garb, Yaakov
    [J]. BUILDING RESEARCH AND INFORMATION, 2019, 47 (04) : 437 - 452
  • [18] Respiratory performance of humans exposed to moderate levels of carbon dioxide
    Mishra, Asit Kumar
    Schiavon, Stefano
    Wargocki, Pawel
    Tham, Kwok Wai
    [J]. INDOOR AIR, 2021, 31 (05) : 1540 - 1552
  • [19] Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone?
    Morawska, Lidia
    Thai, Phong K.
    Liu, Xiaoting
    Asumadu-Sakyi, Akwasi
    Ayoko, Godwin
    Bartonova, Alena
    Bedini, Andrea
    Chai, Fahe
    Christensen, Bryce
    Dunbabin, Matthew
    Gao, Jian
    Hagler, Gayle S. W.
    Jayaratne, Rohan
    Kumar, Prashant
    Lau, Alexis K. H.
    Louie, Peter K. K.
    Mazaheri, Mandana
    Ning, Zhi
    Motta, Nunzio
    Mullins, Ben
    Rahman, Md Mahmudur
    Ristovski, Zoran
    Shafiei, Mahnaz
    Tjondronegoro, Dian
    Westerdahl, Dane
    Williams, Ron
    [J]. ENVIRONMENT INTERNATIONAL, 2018, 116 : 286 - 299
  • [20] Experimental study on occupants' interaction with windows and lights in Mediterranean offices during the non-heating season
    Naspi, Federica
    Arnesano, Marco
    Zampetti, Lorenzo
    Stazi, Francesca
    Revel, Gian Marco
    D'Orazio, Marco
    [J]. BUILDING AND ENVIRONMENT, 2018, 127 : 221 - 238