Asymmetrical high-flow nasal cannula performs similarly to standard interface in patients with acute hypoxemic post-extubation respiratory failure: a pilot study

被引:4
作者
Boscolo, Annalisa [1 ,2 ,3 ]
Pettenuzzo, Tommaso [2 ]
Zarantonello, Francesco [2 ]
Sella, Nicolo [2 ]
Pistollato, Elisa [1 ]
De Cassai, Alessandro [2 ]
Congedi, Sabrina [1 ]
Paiusco, Irene [1 ]
Bertoldo, Giacomo [1 ]
Crociani, Silvia [1 ]
Toma, Francesca [1 ]
Mormando, Giulia [4 ]
Lorenzoni, Giulia [5 ]
Gregori, Dario [5 ]
Navalesi, Paolo [1 ,2 ]
机构
[1] Univ Padua, Dept Med DIMED, Padua, Italy
[2] Padua Univ Hosp, Inst Anaesthesia & Intens Care, 13 Giustiniani St, I-35128 Padua, Italy
[3] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Thorac Surg & Lung Transplant Unit, Padua, Italy
[4] Padua Univ Hosp, Emergency Dept, Padua, Italy
[5] Univ Padua, Dept Cardiac Thorac & Vasc Sci, Unit Biostat Epidemiol & Publ Hlth, Padua, Italy
关键词
High-flow nasal cannula; High flow nasal oxygen; High flow nasal therapy; Asymmetrical cannula; DUET; DEAD SPACE; VENTILATION; SUPPORT; OXYGEN; MUSCLE;
D O I
10.1186/s12890-023-02820-x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Standard high-flow nasal cannula (HFNC) is a respiratory support device widely used to manage post-extubation hypoxemic acute respiratory failure (hARF) due to greater comfort, oxygenation, alveolar recruitment, humidification, and reduction of dead space, as compared to conventional oxygen therapy. On the contrary, the effects of the new asymmetrical HFNC interface (Optiflow (R) Duet system (Fisher & Paykel, Healthcare, Auckland, New Zealand) is still under discussion. Our aim is investigating whether the use of asymmetrical HFNC interface presents any relevant difference, compared with the standard configuration, on lung aeration (as assessed by end-expiratory lung impedance (EELI) measured by electrical impedance tomography (EIT)), diaphragm ultrasound thickening fraction (TFdi) and excursion (DE), ventilatory efficiency (estimated by corrected minute ventilation (MV)), gas exchange, dyspnea, and comfort.Methods Pilot physiological crossover randomized controlled study enrolling 20 adults admitted to the Intensive Care unit, invasively ventilated for at least 24 h, and developing post-extubation hARF, i.e., PaO2/set FiO(2) < 300 mmHg during Venturi mask (VM) within 120 min after extubation. Each HFNC configuration was applied in a randomized 60 min sequence at a flow rate of 60 L/min.Results Global EELI, TFdi, DE, ventilatory efficiency, gas exchange and dyspnea were not significantly different, while comfort was greater during asymmetrical HFNC support, as compared to standard interface (10 [7-10] and 8 [7-9], p-value 0.044).Conclusions In post-extubation hARF, the use of the asymmetrical HFNC, as compared to standard HFNC interface, slightly improved patient comfort without affecting lung aeration, diaphragm activity, ventilatory efficiency, dyspnea and gas exchange.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Efficacy of High-Flow Nasal Cannula Therapy in Acute Hypoxemic Respiratory Failure: Decreased Use of Mechanical Ventilation
    Nagata, Kazuma
    Morimoto, Takeshi
    Fujimoto, Daichi
    Otoshi, Takehiro
    Nakagawa, Atsushi
    Otsuka, Kojiro
    Seo, Ryutaro
    Atsumi, Takahiro
    Tomii, Keisuke
    RESPIRATORY CARE, 2015, 60 (10) : 1390 - 1396
  • [22] High-flow nasal cannula as a post-extubation respiratory support strategy in preterm infants: a systematic review and meta-analysis
    Colleti Junior, Jose
    de Azevedo, Rafael
    Araujo, Orlei
    de Carvalho, Werther Brunow
    JORNAL DE PEDIATRIA, 2020, 96 (04) : 422 - 431
  • [23] Reply to Understanding the benefits of early high-flow nasal cannula for adults with acute hypoxemic respiratory failure in the ED
    Marjanovic, N.
    Mace, J.
    Thille, A. W.
    Frat, J. P.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2019, 37 (08) : 1593 - 1594
  • [24] Monitoring the Efficacy of High-Flow Nasal Cannula Oxygen Therapy in Patients with Acute Hypoxemic Respiratory Failure in the General Respiratory Ward: A Prospective Observational Study
    Zhao, Zhanqi
    Chang, Mei-Yun
    Zhang, Tingting
    Gow, Chien-Hung
    BIOMEDICINES, 2023, 11 (11)
  • [25] Should high-flow through nasal cannula be used during bronchoscopy in critically ill patients with hypoxemic acute respiratory failure?
    Longhini F.
    Bruni A.
    Saraco G.
    Garofalo E.
    Conti G.
    Journal of Anesthesia, Analgesia and Critical Care, 1 (1):
  • [26] Factors associated with unsuccessful high-flow nasal cannula therapy in patients presenting to the emergency department for acute hypoxemic respiratory failure
    Kim, Na Young
    Shin, Ji Sun
    Jeong, Ok Ja
    Kim, Won Young
    INTERNATIONAL EMERGENCY NURSING, 2023, 66
  • [27] Comparison of the effectiveness of high-flow and conventional nasal cannula oxygen therapy in pulmonary embolism patients with acute hypoxemic respiratory failure
    Aksakal, Alperen
    Saglam, Leyla
    Kerget, Bugra
    Yilmazel Ucar, Elif
    TUBERKULOZ VE TORAKS-TUBERCULOSIS AND THORAX, 2021, 69 (04): : 469 - 476
  • [28] Predictors of high-flow nasal cannula failure in pediatric patients with acute respiratory distress
    Saelim, Kantara
    Thirapaleka, Busawan
    Ruangnapa, Kanokpan
    Prasertsan, Pharsai
    Anuntaseree, Wanaporn
    CLINICAL AND EXPERIMENTAL PEDIATRICS, 2022, 65 (12) : 595 - 601
  • [29] Noninvasive approach for de novo acute hypoxemic respiratory failure: noninvasive ventilation, high-flow nasal cannula, both or none?
    Garcia-de-Acilu, Marina
    Patel, Bhakti K.
    Roca, Oriol
    CURRENT OPINION IN CRITICAL CARE, 2019, 25 (01) : 54 - 62
  • [30] Effect of post-extubation high-flow nasal cannula on reintubation in elderly patients: a retrospective propensity score-matched cohort study
    Ko, Ryoung-Eun
    Park, Chul
    Nam, Jimyoung
    Ko, Myeong Gyun
    Na, Soo Jin
    Ahn, Joong Hyun
    Carriere, Keumhee C.
    Jeon, Kyeongman
    THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2020, 14