Simultaneous chromatographic separation of the anomers of saccharides on a polymer sulfobetaine zwitterionic stationary phase

被引:2
|
作者
Yang, Min [1 ]
Mei, Haokun [1 ]
Jiang, Yu [1 ]
Zhang, Feifang [1 ,2 ]
Yu, Ziteng [1 ]
Yang, Bingcheng [1 ,2 ]
机构
[1] East China Univ Sci & Technol, Engn Res Ctr Pharmaceut Proc Chem, Shanghai Frontiers Sci Ctr Optogenet Tech Cell Met, Sch Pharm, Shanghai, Peoples R China
[2] East China Univ Sci & Technol, Engn Res Ctr Pharmaceut Proc Chem, Shanghai Frontiers Sci Ctr Optogenet Tech Cell Met, Sch Pharm, 130 Meilong RD, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
anomer; hydrophilic interaction liquid chromatography; polymer; saccharide; zwitterionic stationary phase; PERFORMANCE LIQUID-CHROMATOGRAPHY; HYDROPHILIC INTERACTION; SUGARS; IDENTIFICATION;
D O I
10.1002/jssc.202300905
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simultaneous chromatographic separation of the anomers of saccharides was achieved by using a polymer zwitterionic stationary phase functionalized by acrylamide-type sulfobetaine. By optimization of separation parameters including column temperature, pH, and flow rate, the column operated in hydrophilic interaction chromatography mode exhibited excellent separation selectivity toward five monosaccharides and their anomers (including ribose, xylose, galactose, glucose, and arabinose) and two disaccharides (lactose and maltose). Baseline separation could be achieved at mild operation conditions such as 20-30 degrees C of column temperature or typical mobile phase composition (85% acetrontrile-15% 20 mM ammonium formate [NH4FA]) with wide pH tolerance range of 2-8. This offers a rapid way to determine the configuration of alpha or beta anomer of the saccharides.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A novel stationary phase for the high performance liquid chromatographic separation and determination of phenols
    Penner, N. A.
    Nesterenko, P. N.
    Khryaschevsky, A. V.
    Stranadko, T. N.
    Mendeleev Communications, (01):
  • [42] Ionic liquid-modified silica as a new stationary phase for chromatographic separation
    X. Wan
    M. Tian
    K. H. Row
    Journal of Analytical Chemistry, 2010, 65 : 798 - 802
  • [43] A novel stationary phase for the high performance liquid chromatographic separation and determination of phenols
    Penner, NA
    Nesterenko, PN
    Khryaschevsky, AV
    Stranadko, TN
    Shpigun, OA
    MENDELEEV COMMUNICATIONS, 1998, 8 (01) : 24 - 27
  • [44] Poly(ethyleneimine) embedded octadecyl based stationary phase for multimodal chromatographic separation
    Zu, Fengjiao
    Qian, Zhongwen
    Li, Feng
    Ren, Xiujun
    Luo, Qiurong
    Gao, Die
    Zhou, Di
    Zhang, Kailian
    Xia, Zhining
    Wang, Lujun
    MICROCHEMICAL JOURNAL, 2020, 156
  • [45] AN IMPROVED CHIRAL STATIONARY PHASE FOR THE CHROMATOGRAPHIC-SEPARATION OF UNDERIVATIZED NAPROXEN ENANTIOMERS
    PIRKLE, WH
    WELCH, CJ
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (11): : 1947 - 1955
  • [46] GAS-CHROMATOGRAPHIC SEPARATION OF CARBOHYDRATE ENANTIOMERS ON A NEW CHIRAL STATIONARY PHASE
    KONIG, WA
    BENECKE, I
    BRETTING, H
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1981, 20 (08): : 693 - 694
  • [47] Separation of polar and hydrophilic compounds: Using a zwitterionic stationary phase in hydrophilic interaction liquid chromatography
    Jonsson, T
    Appelblad, P
    LC GC NORTH AMERICA, 2004, : 72 - 73
  • [48] REVERSED PHASE EXTRACTION CHROMATOGRAPHIC-SEPARATION OF MERCURY WITH TRIBUTYL-PHOSPHATE AS THE STATIONARY PHASE
    SHARMA, C
    KHOPKAR, SM
    CHEMIA ANALITYCZNA, 1985, 30 (01): : 55 - 62
  • [49] Chromatographic investigations of macromolecules in the critical range of liquid chromatography: 11. Polymer blend separation using a reversed stationary phase
    Pasch, H
    Rode, K
    POLYMER, 1998, 39 (25) : 6377 - 6383
  • [50] Separation of polar and hydrophilic compounds using a zwitterionic stationary phase in hydrophilic interaction liquid chromatography
    Jonsson, T
    Appelblad, P
    LC GC EUROPE, 2004, : 40 - 41