Can inertial measurement unit sensors evaluate foot kinematics in drop foot patients using functional electrical stimulation?

被引:1
|
作者
d'Andrea, Francesca [1 ]
Taylor, Paul [2 ,3 ,4 ]
Yang, Kai [5 ,6 ]
Heller, Ben [1 ]
机构
[1] Sheffield Hallam Univ, Sport & Phys Act Res Ctr, Adv Wellbeing Res Ctr AWRC, Sports Engn Res Grp, Sheffield, England
[2] Salisbury Dist Hosp, Dept Clin Sci & Biomed Engn, Natl Clin FES Ctr, Salisbury, England
[3] Bournemouth Univ, Fac Hlth & Social Sci, Poole, England
[4] Salisbury Dist Hosp, Odstock Med Ltd, Salisbury, England
[5] Etexsense, Southampton, England
[6] Univ Southampton, Winchester Sch Art, Southampton, England
来源
关键词
drop foot; foot kinematics; functional electrical stimulation; gait analysis; inertial measurement unit; MULTIPLE-SCLEROSIS; GAIT KINEMATICS; MOTION; EXPERIENCE; PEOPLE;
D O I
10.3389/fnhum.2023.1225086
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The accuracy of inertial measurement units (IMUs) in measuring foot motion in the sagittal plane has been previously compared to motion capture systems for healthy and impaired participants. Studies analyzing the accuracy of IMUs in measuring foot motion in the frontal plane are lacking. Drop foot patients use functional electrical stimulation (FES) to improve walking and reduce the risk of tripping and falling by improving foot dorsiflexion and inversion-eversion. Therefore, this study aims to evaluate if IMUs can estimate foot angles in the frontal and sagittal planes to help understand the effects of FES on drop foot patients in clinical settings. Two Gait Up sensors were used to estimate foot dorsi-plantar flexion and inversion-eversion angles in 13 unimpaired participants and 9 participants affected by drop foot while walking 6 m in a straight line. Unimpaired participants were asked to walk normally at three self-selected speeds and to simulate drop foot. Impaired participants walked with and without FES assistance. Foot angles estimated by the IMUs were compared with those measured from a motion capture system using curve RMSE and Bland Altman limits of agreement. Between participant groups, overall errors of 7.95 degrees +/- 3.98 degrees, -1.12 degrees +/- 4.20 degrees, and 1.38 degrees +/- 5.05 degrees were obtained for the dorsi-plantar flexion range of motion, dorsi-plantar flexion at heel strike, and inversion-eversion at heel strike, respectively. The between-system comparison of their ability to detect dorsi-plantar flexion and inversion-eversion differences associated with FES use on drop foot patients provided limits of agreement too large for IMUs to be able to accurately detect the changes in foot kinematics following FES intervention. To the best of the authors' knowledge, this is the first study to evaluate IMU accuracy in the estimation of foot inversion-eversion and analyze the potential of using IMUs in clinical settings to assess gait for drop foot patients and evaluate the effects of FES. From the results, it can be concluded that IMUs do not currently represent an alternative to motion capture to evaluate foot kinematics in drop foot patients using FES.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Current Generation Circuit to Functional Electrical Stimulate Foot-drop Patients
    Viet Dung Nguyen
    Quang Dan Chu
    2017 IEEE 4TH INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATION (ICSIMA 2017), 2017,
  • [32] Functional Electrical Stimulation for Foot Drop in Post-Stroke People: Quantitative Effects on Step-to-Step Symmetry of Gait Using a Wearable Inertial Sensor
    Schifino, Giulia
    Cimolin, Veronica
    Pau, Massimiliano
    da Cunha, Maira Jaqueline
    Leban, Bruno
    Porta, Micaela
    Galli, Manuela
    Souza Pagnussat, Aline
    SENSORS, 2021, 21 (03) : 1 - 11
  • [33] DESIGN AND IMPLEMENTATION OF A COST-EFFECTIVE , FUNCTIONAL ELECTRICAL STIMULATION DEVICE FOR FOOT DROP REHABILITATION
    Chiriac, Oana-Andreea
    Adochiei, Felix-Constantin
    Trocan, Nicoleta-Iuliana
    Nistor, Mircea-Iulian
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2025, 70 (01):
  • [34] A Novel Capacitive Step Sensor to Trigger Stimulation on Functional Electrical Stimulators Devices for Drop Foot
    Aqueveque, Pablo
    Pastene, Francisco
    Osorio, Rodrigo
    Saavedra, Francisco
    Pinto, Daniela
    Ortega-Bastidas, Paulina
    Gomez, Britam
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (12) : 3083 - 3088
  • [35] The impact of walking speed on the effects of functional electrical stimulation for foot drop in people with multiple sclerosis
    Miller, L.
    Rafferty, D.
    Paul, L.
    Mattison, P.
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2016, 11 (06) : 478 - 483
  • [36] Gait Orthosis Lokomat Combined with Functional Electrical Stimulation for Foot Drop Correction: A Feasibility Study
    Spaich, Erika Geraldina
    Bog, Mette F.
    Erkocevic, Ema
    Smidstrup, Anne
    Andersen, Ole Kaeseler
    Nielsen, Jorgen Feldbaek
    REPLACE, REPAIR, RESTORE, RELIEVE - BRIDGING CLINICAL AND ENGINEERING SOLUTIONS IN NEUROREHABILITATION, 2014, 7 : 751 - 757
  • [37] Smart Protocols for Physical Therapy of Foot Drop Based on Functional Electrical Stimulation: A Case Study
    Malesevic, Jovana
    Konstantinovic, Ljubica
    Bijelic, Goran
    Malesevic, Nebojsa
    HEALTHCARE, 2021, 9 (05)
  • [38] Technical developments of functional electrical stimulation to correct drop foot: Sensing, actuation and control strategies
    Melo, P. L.
    Silva, M. T.
    Martins, J. M.
    Newman, D. J.
    CLINICAL BIOMECHANICS, 2015, 30 (02) : 101 - 113
  • [39] A systematic literature review of ankle-foot orthosis and functional electrical stimulation foot-drop treatments for persons with multiple sclerosis
    Byrnes-Blanco, Laura
    Reed, Kyle
    Dubey, Rajiv
    Carey, Stephanie L.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2023, 47 (04) : 358 - 367
  • [40] Shefstim: Automated Setup of Functional Electrical Stimulation for Drop Foot Using a 64 Channel Prototype Stimulator and Electrode Array
    Heller, Ben W.
    Clarke, Alison J.
    Good, Timothy R.
    Healey, Jamie
    Nair, Krishnan P. S.
    Pratt, Emma J.
    Reeves, Mark L.
    van der Meulen, Jill M.
    Barker, Anthony T.
    ANNALS OF NEUROLOGY, 2012, 72 : S35 - S36