Enhancement of the critical heat flux for downward-facing saturated pool boiling on the reticular hollow shell structure surfaces

被引:1
|
作者
Zhong, Dawen [1 ]
Lian, Xuexin [1 ]
Shi, Haopeng [1 ,2 ]
Zhang, Junfeng [1 ]
Meng, Jian [3 ]
Zhang, Jingyu [1 ]
机构
[1] North China Elect Power Univ, Beijing Key Lab Pass Nucl Power Safety & Technol, Beijing 102206, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Nucl Sci & Engn, Shanghai 240200, Peoples R China
[3] Tsinghua Univ, Sch Aerosp Engn, Beijing 100084, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Critical heat flux; Downward facing boiling; Boiling heat transfer coefficient; In vessel retention; Boiling heat transfer enhancement; HONEYCOMB POROUS PLATE; CHF ENHANCEMENT; COPPER; MODEL; ORIENTATION;
D O I
10.1016/j.applthermaleng.2023.121635
中图分类号
O414.1 [热力学];
学科分类号
摘要
In-vessel retention (IVR) technology was currently an effective strategy for retaining molten materials in the reactor pressure vessel (RPV) when the nuclear power plants occurred severe accident, further ensuring the integrity of RPV. The effectiveness of IVR depended on the critical heat flux (CHF) of external reactor vessel cooling (ERVC). A novel type of reticular hollow shell structure (RHS) was designed to meet this need. Five RHS surfaces were designed and the pool boiling heat transfer performance were investigated in saturated deionized water, the experimental inclination angles were 5 degrees, 30 degrees, 45 degrees, 60 degrees and 90 degrees. The boiling heat transfer coefficient (BHTC) and CHF were measured by steady-state heating and transient quenching methods. The experiment results showed that the CHF increased with the increase of inclination angles, and the CHF of all RHS surfaces were significantly enhanced compared with the plain surface. The maximum CHF value and the maximum CHF enhancement exhibited on surface 4, with a maximum CHF of 2992.2 kW/m2. When the inclination angle was 30 degrees, the maximum CHF could reach 2338.6 kW/m2, which was 160.3% enhancement over the plain surface. Surface 1 and surface 3 had better BHTCs, and the maximum values were 178.3 kW/(m2 & sdot;K) and 126.8 kW/ (m2 & sdot;K), respectively, which were much better than other structured surfaces. The RHS could form a gas-liquid conversion system, which was composed of cavities and alternating channels to increase the surface nucleation sites and accelerate the circulation of cooling water, thus obtained the high CHF and high BHTC characteristics. RHS provided a large enough CHF margin to ensure that the RPV was continuously cooled and its integrity was maintained. Finally, the behavior of bubbles generation, coalescence, sliding and detachment in reticular hollow shell structure were systematically analyzed.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Critical heat flux for downward-facing saturated pool boiling on pin fin surfaces
    Zhong, Dawen
    Meng, Ji'an
    Li, Zhixin
    Guo, Zengyuan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 87 : 201 - 211
  • [2] Effects of a porous honeycomb structure on critical heat flux in downward-facing saturated pool boiling
    Wang, Kai
    Gong, Haiguang
    Wang, Laishun
    Erkan, Nejdet
    Okamoto, Koji
    APPLIED THERMAL ENGINEERING, 2020, 170
  • [3] The characteristics and correlation of saturated pool boiling critical heat flux for downward-facing plain heating surface
    Deng, Kuanghan
    Wang, Chenglong
    Qiu, Suizheng
    Su, G. H.
    Tian, Wenxi
    Wang, Yun
    He, Xiaoqiang
    APPLIED THERMAL ENGINEERING, 2020, 166 (166)
  • [4] Critical heat flux for downward-facing pool boiling on CANDU calandria vessel
    Behdadi, Azin
    Talebi, Farshad
    Luxat, John
    ANNALS OF NUCLEAR ENERGY, 2017, 110 : 768 - 778
  • [5] Critical heat flux enhancement in downward-facing pool boiling with radiation induced surface activation effect
    Gong, Haiguang
    Khan, Abdul R.
    Erkan, Nejdet
    Wang, Laishun
    Okamoto, Koji
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 : 93 - 102
  • [6] TRANSIENT BOILING FROM INCLINED AND DOWNWARD-FACING SURFACES IN A SATURATED POOL
    ELGENK, MS
    GUO, ZX
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (06): : 414 - 422
  • [7] Critical heat flux for downward-facing pool boiling on CANDU calandria tube surface
    Behdadi, Azin
    Talebi, Farshad
    Luxat, John
    NUCLEAR ENGINEERING AND DESIGN, 2017, 315 : 104 - 116
  • [8] Effects of flow obstacles on pool boiling critical heat flux of a downward-facing metal heater
    Son, Hong Hyun
    Song, Kyusang
    Jeong, Uiju
    Seo, Gwang Hyeok
    Jeun, Gyoodong
    Kim, Sung Joong
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 80 : 313 - 326
  • [9] Effects of downward-facing surface type and inclination on critical heat flux during pool boiling
    Gong, H.
    Wang, L.
    Khan, A. R.
    Erkan, N.
    Okamoto, K.
    ANNALS OF NUCLEAR ENERGY, 2018, 113 : 344 - 352
  • [10] BOILING HEAT TRANSFER AND CRITICAL HEAT FLUX ENHANCEMENT OF UPWARD- AND DOWNWARD-FACING HEATER IN NANOFLUIDS
    Sulaiman, Muhamad Zuhairi
    Takamura, Masahiro
    Nakahashi, Kazuki
    Okawa, Tomio
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 5, 2012, : 451 - +