CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy

被引:6
|
作者
Reiners, Keaton [1 ,2 ]
Dagan, Roi [1 ,3 ]
Holtzman, Adam [4 ]
Bryant, Curtis [1 ,3 ]
Andersson, Sebastian [5 ]
Nilsson, Rasmus [5 ]
Hong, Liu [6 ]
Johnson, Perry [1 ,3 ]
Zhang, Yawei [1 ,3 ]
机构
[1] Univ Florida, Hlth Proton Therapy Inst, Jacksonville, FL 32206 USA
[2] Univ Florida, Med Phys Grad Program, Coll Med, Gainesville, FL 32610 USA
[3] Univ Florida, Dept Radiat Oncol, Coll Med, Gainesville, FL 32610 USA
[4] Mayo Clin, Dept Radiat Oncol, Jacksonville, FL 32224 USA
[5] RaySearch Labs, SE-10365 Stockholm, Sweden
[6] Ion Beam Applicat SA, B-1348 Louvain la neuve, Belgium
关键词
proton adaptive therapy; PBS; cone-beam CT; head and neck; synthetic CT; DEFORMABLE IMAGE REGISTRATION; MODULATED RADIATION-THERAPY; BEAM COMPUTED-TOMOGRAPHY; CANCER PATIENTS; CORRECTION ALGORITHM; POTENTIAL BENEFITS; SCATTER CORRECTION; DOSIMETRIC IMPACT; PHOTON; RADIOTHERAPY;
D O I
10.3390/cancers15153881
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Head and neck cancer patients require adaptive radiation therapy due to aggressive tumor response, changes in anatomy, and difficulties with setup reproducibility. Additionally, protons are more sensitive to patient setup uncertainty and anatomical change than photons. At our institution, verification CTs are often utilized to evaluate changes in anatomy and dose coverage during the treatment course. Nevertheless, they are limited by low frequency and an inability to detect changes in treatment setup. Furthermore, our current clinical workflow does not have definitive thresholds for adaptive therapy plan review, meaning every verification CT must be reviewed by a physician and physicist. We analyzed the feasibility of higher-frequency dose monitoring and triggering a plan review for adaptive proton therapy by recalculating the plan dose on synthetic CTs produced from daily patient setup cone-beam CTs. Plan review triggers were established following the analysis of cohort data. Two synthetic CT algorithms were developed and evaluated. Both resulted in images that outperformed the verification CTs in dosimetric accuracy. A more efficient and accurate adaptive proton therapy workflow was successfully established. Purpose: To investigate the feasibility of using cone-beam computed tomography (CBCT)-derived synthetic CTs to monitor the daily dose and trigger a plan review for adaptive proton therapy (APT) in head and neck cancer (HNC) patients. Methods: For 84 HNC patients treated with proton pencil-beam scanning (PBS), same-day CBCT and verification CT (vfCT) pairs were retrospectively collected. The ground truth CT (gtCT) was created by deforming the vfCT to the same-day CBCT, and it was then used as a dosimetric baseline and for establishing plan review trigger recommendations. Two different synthetic CT algorithms were tested; the corrected CBCT (corrCBCT) was created using an iterative image correction method and the virtual CT (virtCT) was created by deforming the planning CT to the CBCT, followed by a low-density masking process. Clinical treatment plans were recalculated on the image sets for evaluation. Results: Plan review trigger criteria for adaptive therapy were established after closely reviewing the cohort data. Compared to the vfCT, the corrCBCT and virtCT reliably produced dosimetric data more similar to the gtCT. The average discrepancy in D99 for high-risk clinical target volumes (CTV) was 1.1%, 0.7%, and 0.4% and for standard-risk CTVs was 1.8%, 0.5%, and 0.5% for the vfCT, corrCBCT, and virtCT, respectively. Conclusion: Streamlined APT has been achieved with the proposed plan review criteria and CBCT-based synthetic CT workflow.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy
    Chen, Wen
    Li, Yimin
    Yuan, Nimu
    Qi, Jinyi
    Dyer, Brandon A.
    Sensoy, Levent
    Benedict, Stanley H.
    Shang, Lu
    Rao, Shyam
    Rong, Yi
    FRONTIERS IN ARTIFICIAL INTELLIGENCE, 2021, 3
  • [32] Onboard cone-beam CT-based replan evaluation for head and neck proton therapy
    Stanforth, Alexander
    Lin, Liyong
    Beitler, Jonathan J.
    Janopaul-Naylor, James R.
    Chang, Chih-Wei
    Press, Robert H.
    Patel, Sagar A.
    Zhao, Jennifer
    Eaton, Bree
    Schreibmann, Eduard E.
    Jung, James
    Bohannon, Duncan
    Liu, Tian
    Yang, Xiaofeng
    McDonald, Mark W.
    Zhou, Jun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [33] Assessment of the use of synthetic CT produced by deformable image registration of planning CT and CBCT in adaptive radiotherapy treatments of head and neck cancers
    Sanju
    Mukherji, Ashutosh
    Nanda, Sambit S.
    Dokania, Shubham
    Kataria, Alka
    Kumar, Narender
    Saini, Vinay
    Barman, Sanjay
    Epili, Dandpani R.
    Choubey, Ajay
    Patil, Ninad H.
    Krishnan, Ajay
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2025, 131
  • [34] Cone-beam computed tomography (CBCT) for adaptive image guided head and neck radiation therapy
    Hvid, Christian A.
    Elstrom, Ulrik V.
    Jensen, Kenneth
    Grau, Cai
    ACTA ONCOLOGICA, 2018, 57 (04) : 552 - 556
  • [35] Phantom based evaluation of CT to CBCT image registration for proton therapy dose recalculation
    Landry, Guillaume
    Dedes, George
    Zoellner, Christoph
    Handrack, Josefine
    Janssens, Guillaume
    de Xivry, Jonathan Orban
    Reiner, Michael
    Paganelli, Chiara
    Riboldi, Marco
    Kamp, Florian
    Soehn, Matthias
    Wilkens, Jan J.
    Baroni, Guido
    Belka, Claus
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) : 595 - 613
  • [36] Comparing cone- beam CT intensity correction methods for dose recalculation in adaptive intensity- modulated photon and proton therapy for head and neck cancer
    Kurz, Christopher
    Dedes, George
    Resch, Andreas
    Reiner, Michael
    Ganswindt, Ute
    Nijhuis, Reinoud
    Thieke, Christian
    Belka, Claus
    Parodi, Katia
    Landry, Guillaume
    ACTA ONCOLOGICA, 2015, 54 (09) : 1651 - 1657
  • [37] MV CBCT based assessment of setup uncertainties and planning target volume margin in head and neck cancer
    Sikdar, Debanjan
    Krishnan, Ajay S.
    Namitha, Rs
    Chakravarty, Abhishek
    Gupta, Dhiraj
    Gupta, Sweety
    Kumar, Arvind
    Joseph, Deepa
    Gupta, Manoj
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (02) : 141 - 147
  • [38] Leveraging GAN-based CBCT-to-CT translation models for enhanced image quality and accurate photon and proton dose calculation in adaptive radiotherapy
    Liang, Zhiwen
    Wei, Hui
    Liu, Gang
    Cheng, Mengjie
    Gao, Jiaqi
    Li, Song
    Tian, Xin
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (01)
  • [39] Effectiveness of robust optimization in intensity-modulated proton therapy planning for head and neck cancers
    Liu, Wei
    Frank, Steven J.
    Li, Xiaoqiang
    Li, Yupeng
    Park, Peter C.
    Dong, Lei
    Zhu, X. Ronald
    Mohan, Radhe
    MEDICAL PHYSICS, 2013, 40 (05)
  • [40] Validation of automated complex head and neck treatment planning with pencil beam scanning proton therapy
    Hedrick, Samantha Grace
    Petro, Scott
    Ward, Alex
    Morris, Bart
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):