CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy

被引:6
|
作者
Reiners, Keaton [1 ,2 ]
Dagan, Roi [1 ,3 ]
Holtzman, Adam [4 ]
Bryant, Curtis [1 ,3 ]
Andersson, Sebastian [5 ]
Nilsson, Rasmus [5 ]
Hong, Liu [6 ]
Johnson, Perry [1 ,3 ]
Zhang, Yawei [1 ,3 ]
机构
[1] Univ Florida, Hlth Proton Therapy Inst, Jacksonville, FL 32206 USA
[2] Univ Florida, Med Phys Grad Program, Coll Med, Gainesville, FL 32610 USA
[3] Univ Florida, Dept Radiat Oncol, Coll Med, Gainesville, FL 32610 USA
[4] Mayo Clin, Dept Radiat Oncol, Jacksonville, FL 32224 USA
[5] RaySearch Labs, SE-10365 Stockholm, Sweden
[6] Ion Beam Applicat SA, B-1348 Louvain la neuve, Belgium
关键词
proton adaptive therapy; PBS; cone-beam CT; head and neck; synthetic CT; DEFORMABLE IMAGE REGISTRATION; MODULATED RADIATION-THERAPY; BEAM COMPUTED-TOMOGRAPHY; CANCER PATIENTS; CORRECTION ALGORITHM; POTENTIAL BENEFITS; SCATTER CORRECTION; DOSIMETRIC IMPACT; PHOTON; RADIOTHERAPY;
D O I
10.3390/cancers15153881
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Head and neck cancer patients require adaptive radiation therapy due to aggressive tumor response, changes in anatomy, and difficulties with setup reproducibility. Additionally, protons are more sensitive to patient setup uncertainty and anatomical change than photons. At our institution, verification CTs are often utilized to evaluate changes in anatomy and dose coverage during the treatment course. Nevertheless, they are limited by low frequency and an inability to detect changes in treatment setup. Furthermore, our current clinical workflow does not have definitive thresholds for adaptive therapy plan review, meaning every verification CT must be reviewed by a physician and physicist. We analyzed the feasibility of higher-frequency dose monitoring and triggering a plan review for adaptive proton therapy by recalculating the plan dose on synthetic CTs produced from daily patient setup cone-beam CTs. Plan review triggers were established following the analysis of cohort data. Two synthetic CT algorithms were developed and evaluated. Both resulted in images that outperformed the verification CTs in dosimetric accuracy. A more efficient and accurate adaptive proton therapy workflow was successfully established. Purpose: To investigate the feasibility of using cone-beam computed tomography (CBCT)-derived synthetic CTs to monitor the daily dose and trigger a plan review for adaptive proton therapy (APT) in head and neck cancer (HNC) patients. Methods: For 84 HNC patients treated with proton pencil-beam scanning (PBS), same-day CBCT and verification CT (vfCT) pairs were retrospectively collected. The ground truth CT (gtCT) was created by deforming the vfCT to the same-day CBCT, and it was then used as a dosimetric baseline and for establishing plan review trigger recommendations. Two different synthetic CT algorithms were tested; the corrected CBCT (corrCBCT) was created using an iterative image correction method and the virtual CT (virtCT) was created by deforming the planning CT to the CBCT, followed by a low-density masking process. Clinical treatment plans were recalculated on the image sets for evaluation. Results: Plan review trigger criteria for adaptive therapy were established after closely reviewing the cohort data. Compared to the vfCT, the corrCBCT and virtCT reliably produced dosimetric data more similar to the gtCT. The average discrepancy in D99 for high-risk clinical target volumes (CTV) was 1.1%, 0.7%, and 0.4% and for standard-risk CTVs was 1.8%, 0.5%, and 0.5% for the vfCT, corrCBCT, and virtCT, respectively. Conclusion: Streamlined APT has been achieved with the proposed plan review criteria and CBCT-based synthetic CT workflow.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] CBCT-Based Adaptive Assessment Workflow for Intensity Modulated Proton Therapy for Head and Neck Cancer
    De Ornelas, Mariluz
    Xu, Yihang
    Padgett, Kyle
    Schmidt, Ryder M.
    Butkus, Michael
    Diwanji, Tejan
    Luciani, Gus
    Lambiase, Jason
    Samuels, Stuart
    Samuels, Michael
    Dogan, Nesrin
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 7 (04) : 29 - 41
  • [2] Assessment of CBCT-based synthetic CT generation accuracy for adaptive radiotherapy planning
    O'Hara, Christopher J.
    Bird, David
    Al-Qaisieh, Bashar
    Speight, Richard
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11):
  • [3] Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations
    Held, Mareike
    Sneed, Penny K.
    Fogh, Shannon E.
    Pouliot, Jean
    Morin, Olivier
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 458 - 471
  • [4] Modified fast adaptive scatter kernel superposition (mfASKS) correction and its dosimetric impact on CBCT-based proton therapy dose calculation
    Nomura, Yusuke
    Xu, Qiong
    Peng, Hao
    Takao, Seishin
    Shimizu, Shinichi
    Xing, Lei
    Shirato, Hiroki
    MEDICAL PHYSICS, 2020, 47 (01) : 190 - 200
  • [5] Measurement-based range evaluation for quality assurance of CBCT-based dose calculations in adaptive proton therapy
    Neppl, Sebastian
    Kurz, Christopher
    Kopl, Daniel
    Yohannes, Indra
    Schneider, Moritz
    Bondesson, David
    Rabe, Moritz
    Belka, Claus
    Dietrich, Olaf
    Landry, Guillaume
    Parodi, Katia
    Kamp, Florian
    MEDICAL PHYSICS, 2021, 48 (08) : 4148 - 4159
  • [6] Feasibility of CBCT-based proton dose calculation using a histogram-matching algorithm in proton beam therapy
    Arai, Kazuhiro
    Kadoya, Noriyuki
    Kato, Takahiro
    Endo, Hiromitsu
    Komori, Shinya
    Abe, Yoshitomo
    Nakamura, Tatsuya
    Wada, Hitoshi
    Kikuchi, Yasuhiro
    Takai, Yoshihiro
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 68 - 76
  • [7] Comparison of CBCT based synthetic CT methods suitable for proton dose calculations in adaptive proton therapy
    Thummerer, Adrian
    Zaffino, Paolo
    Meijers, Arturs
    Marmitt, Gabriel Guterres
    Seco, Joao
    Steenbakkers, Roel J. H. M.
    Langendijk, Johannes A.
    Both, Stefan
    Spadea, Maria F.
    Knopf, Antje C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (09)
  • [8] Evaluation of CBCT scatter correction using deep convolutional neural networks for head and neck adaptive proton therapy
    Lalonde, Arthur
    Winey, Brian
    Verburg, Joost
    Paganetti, Harald
    Sharp, Gregory C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24)
  • [9] Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy
    Park, Yang-Kyun
    Sharp, Gregory C.
    Phillips, Justin
    Winey, Brian A.
    MEDICAL PHYSICS, 2015, 42 (08) : 4449 - 4459
  • [10] Water equivalent path length calculations using scatter-corrected head and neck CBCT images to evaluate patients for adaptive proton therapy
    Kim, Jihun
    Park, Yang-Kyun
    Sharp, Gregory
    Busse, Paul
    Winey, Brian
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01) : 59 - 72