Agreement between cardiac output estimation with a wireless, wearable pulse decomposition analysis device and continuous thermodilution in post cardiac surgery intensive care unit patients

被引:4
|
作者
Khanna, Ashish K. K. [1 ,2 ,3 ]
Garcia, Julio O. [4 ]
Saha, Amit K. [3 ,5 ]
Harris, Lynnette [3 ,5 ]
Baruch, Martin [6 ]
Martin, R. Shayn [7 ]
机构
[1] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Sch Med, Dept Anesthesiol,Sect Crit Care Med, Winston Salem, NC 27109 USA
[2] Outcomes Res Consortium, Cleveland, OH 44195 USA
[3] Perioperat Outcomes & Informat Collaborat POIC, Winston Salem, NC 27109 USA
[4] Wake Forest Univ, Sch Med, Winston Salem, NC USA
[5] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Dept Anesthesiol, Sch Med, Winston Salem, NC USA
[6] Caretaker Med, Charlottesville, VA USA
[7] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Dept Surg, Sch Med, Winston Salem, NC USA
关键词
Pulse decomposition analysis; Cardiac output; Hemodynamics; Wireless; Monitoring; Cardiac surgery; Postoperative; Intensive care unit; ACCURACY; PRESSURE; NEXFIN; CNAP;
D O I
10.1007/s10877-023-01059-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
PurposePulse Decomposition Analysis (PDA) uses integration of the systolic area of a distally transmitted aortic pulse as well as arterial stiffness estimates to compute cardiac output. We sought to assess agreement of cardiac output (CO) estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CCO) and a wireless, wearable noninvasive device, (Vitalstream, Caretaker Medical, Charlottesville, VA), that utilizes the Pulse Decomposition Analysis (CO-PDA) method in postoperative cardiac surgery patients in the intensive care unit.MethodsCO-CCO measurements were compared with post processed CO-PDA measurements in prospectively enrolled adult cardiac surgical intensive care unit patients. Uncalibrated CO-PDA values were compared for accuracy with CO-CCO via a Bland-Altman analysis considering repeated measurements and a concordance analysis with a 10% exclusion zone.Results259.7 h of monitoring data from 41 patients matching 15,583 data points were analyzed. Mean CO-CCO was 5.55 L/min, while mean values for the CO-PDA were 5.73 L/min (mean of differences +- SD 0.79 & PLUSMN; 1.11 L/min; limits of agreement - 1.43 to 3.01 L/min), with a percentage error of 37.5%. CO-CCO correlation with CO-PDA was moderate (0.54) and concordance was 0.83.ConclusionCompared with the CO-CCO Swan-Ganz, cardiac output measurements obtained using the CO-PDA were not interchangeable when using a 30% threshold. These preliminary results were within the 45% limits for minimally invasive devices, and pending further robust trials, the CO-PDA offers a noninvasive, wireless solution to complement and extend hemodynamic monitoring within and outside the ICU.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 46 条
  • [31] Comparison between prognostic scores of patients undergoing cardiac surgery: which is the best score to predict mortality and length of stay in a surgical intensive care unit?
    LAA Campos
    RV Gomes
    B Tura
    AGR Carvalho
    FG Aranha
    PMM Nogueira
    MAO Fernandes
    R Farina
    DJ Silva Filho
    HJF Dohmann
    Critical Care, 7 (Suppl 3):
  • [32] RETRACTED: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery (Retracted Article)
    Mayer, J.
    Boldt, J.
    Schoellhorn, T.
    Roehm, K. D.
    Mengistu, A. M.
    Suttner, S.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (02) : 176 - 182
  • [33] Performance of Sequential Organ Failure Assessment and Simplified Acute Physiology Score II for Post-Cardiac Surgery Patients in Intensive Care Unit
    Xu, Fei
    Li, Weina
    Zhang, Cheng
    Cao, Rong
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [34] ANALYSIS OF FUNCTIONAL CAPACITY AND RISK FACTORS IN PATIENTS WITH PROLONGED TREATMENT IN INTENSIVE CARE UNIT AFTER CARDIAC SURGERY - LONG-TERM RESULTS
    Abedinov, Filip
    Groudeva, Violeta
    Petrov, Iliyan
    Angelov, Hristo
    Tsaryanski, Georgy
    Krastev, Plamen
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2021, 74 (01): : 127 - 138
  • [35] Comparing different postoperative sedation strategies for patients in the intensive care unit after cardiac surgery: A systematic review of randomized controlled trials and network meta-analysis
    Hu, Qinxue
    Liu, Xing
    Xiang, Yuancai
    Lei, Xianying
    Yu, Hong
    Liu, Li
    Feng, Jianguo
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2024, 135 (02) : 180 - 194
  • [36] Hyperglycemia is associated with worse 3-year survival in older patients admitted to the intensive care unit after non-cardiac surgery: Post hoc analysis of a randomized trial
    Li, Mo
    Deng, Chun-Mei
    Su, Xian
    Zhang, Dan-Feng
    Ding, Mao
    Ma, Jia-Hui
    Wang, Dong-Xin
    FRONTIERS IN MEDICINE, 2022, 9
  • [37] Association between serum creatinine-to-albumin ratio and 28-day mortality in intensive care unit patients following cardiac surgery: analysis of mimic-iv data
    Shi, Pengtao
    Rui, Shen
    Meng, Qingyou
    BMC CARDIOVASCULAR DISORDERS, 2025, 25 (01):
  • [38] Cardiac output estimation by pulse wave analysis using the pressure recording analytical method and intermittent pulmonary artery thermodilution A method comparison study after off-pump coronary artery bypass surgery
    Greiwe, Gillis
    Luehsen, Katharina
    Hapfelmeier, Alexander
    Rogge, Dorothea
    Kubik, Mathias
    Schulte-Uentrop, Leonie
    Saugel, Bernd
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (10) : 920 - 925
  • [39] Method comparison – a new approach to implementing the Bland–Altman analysis to estimate the precision of a new method: tested on 30 critically ill patients monitored with pulse pressure analysis and continuous cardiac output vs intermittent thermodilution
    M Cecconi
    J Poloniecki
    G Della Rocca
    J Ball
    R Grounds
    A Rhodes
    Critical Care, 11 (Suppl 2):
  • [40] Continuous and minimally invasive cardiac output monitoring by long time interval analysis of a radial arterial pressure waveform: assessment using a large, public intensive care unit patient database
    Zhang, G.
    Mukkamala, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (03) : 339 - 344