Agreement between cardiac output estimation with a wireless, wearable pulse decomposition analysis device and continuous thermodilution in post cardiac surgery intensive care unit patients

被引:4
|
作者
Khanna, Ashish K. K. [1 ,2 ,3 ]
Garcia, Julio O. [4 ]
Saha, Amit K. [3 ,5 ]
Harris, Lynnette [3 ,5 ]
Baruch, Martin [6 ]
Martin, R. Shayn [7 ]
机构
[1] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Sch Med, Dept Anesthesiol,Sect Crit Care Med, Winston Salem, NC 27109 USA
[2] Outcomes Res Consortium, Cleveland, OH 44195 USA
[3] Perioperat Outcomes & Informat Collaborat POIC, Winston Salem, NC 27109 USA
[4] Wake Forest Univ, Sch Med, Winston Salem, NC USA
[5] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Dept Anesthesiol, Sch Med, Winston Salem, NC USA
[6] Caretaker Med, Charlottesville, VA USA
[7] Wake Forest Univ, Atrium Hlth Wake Forest Baptist Med Ctr, Dept Surg, Sch Med, Winston Salem, NC USA
关键词
Pulse decomposition analysis; Cardiac output; Hemodynamics; Wireless; Monitoring; Cardiac surgery; Postoperative; Intensive care unit; ACCURACY; PRESSURE; NEXFIN; CNAP;
D O I
10.1007/s10877-023-01059-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
PurposePulse Decomposition Analysis (PDA) uses integration of the systolic area of a distally transmitted aortic pulse as well as arterial stiffness estimates to compute cardiac output. We sought to assess agreement of cardiac output (CO) estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CCO) and a wireless, wearable noninvasive device, (Vitalstream, Caretaker Medical, Charlottesville, VA), that utilizes the Pulse Decomposition Analysis (CO-PDA) method in postoperative cardiac surgery patients in the intensive care unit.MethodsCO-CCO measurements were compared with post processed CO-PDA measurements in prospectively enrolled adult cardiac surgical intensive care unit patients. Uncalibrated CO-PDA values were compared for accuracy with CO-CCO via a Bland-Altman analysis considering repeated measurements and a concordance analysis with a 10% exclusion zone.Results259.7 h of monitoring data from 41 patients matching 15,583 data points were analyzed. Mean CO-CCO was 5.55 L/min, while mean values for the CO-PDA were 5.73 L/min (mean of differences +- SD 0.79 & PLUSMN; 1.11 L/min; limits of agreement - 1.43 to 3.01 L/min), with a percentage error of 37.5%. CO-CCO correlation with CO-PDA was moderate (0.54) and concordance was 0.83.ConclusionCompared with the CO-CCO Swan-Ganz, cardiac output measurements obtained using the CO-PDA were not interchangeable when using a 30% threshold. These preliminary results were within the 45% limits for minimally invasive devices, and pending further robust trials, the CO-PDA offers a noninvasive, wireless solution to complement and extend hemodynamic monitoring within and outside the ICU.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 46 条
  • [21] Interaction between warfarin and short-term intravenous amiodarone in intensive care unit patients after cardiac surgery
    Takase, Tomoki
    Ikesue, Hiroaki
    Tohi, Makiko
    Ueta, Hiroshi
    Mima, Hiroyuki
    Koyama, Tadaaki
    Hashida, Tohru
    JOURNAL OF PHARMACEUTICAL HEALTH CARE AND SCIENCES, 2018, 4
  • [22] Microcirculation and its relation to continuous subcutaneous glucose sensor accuracy in cardiac surgery patients in the intensive care unit
    Siegelaar, Sarah E.
    Barwari, Temo
    Hermanides, Jeroen
    van der Voort, Peter H. J.
    Hoekstra, Joost B. L.
    DeVries, J. Hans
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (05) : 1283 - 1289
  • [23] Interaction between warfarin and short-term intravenous amiodarone in intensive care unit patients after cardiac surgery
    Tomoki Takase
    Hiroaki Ikesue
    Makiko Tohi
    Hiroshi Ueta
    Hiroyuki Mima
    Tadaaki Koyama
    Tohru Hashida
    Journal of Pharmaceutical Health Care and Sciences, 4 (1)
  • [24] Autocalibrating pulse contour analysis based on radial artery applanation tonometry for continuous non-invasive cardiac output monitoring in intensive care unit patients after major gastrointestinal surgery-a prospective method comparison study
    Wagner, J. Y.
    Langemann, M.
    Schoen, G.
    Kluge, S.
    Reuter, D. A.
    Saugel, B.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (03) : 340 - 345
  • [25] Cardiac Output Measurement With Echocardiography and Pressure Recording Analytical Method in Pediatric Patients Admitted to the Cardiac Intensive Care Unit: A Retrospective Assessment of Bias Between the Two Methods
    Ricci, Zaccaria
    Cecconi, Giulia
    Lillo, Rosa
    Di Chiara, Luca
    Toscano, Alessandra
    Iacobelli, Roberta
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (05) : 1351 - 1357
  • [26] Disagreement between pulse contour analysis and transpulmonary thermodilution for cardiac output monitoring after routine therapeutic interventions in ICU patients with acute circulatory failure
    Muller, Laurent
    Candela, Damien
    Nyonzyma, Lambert
    Mattatia, Laurent
    Suehs, Carey
    Fabbro-Peray, Pascale
    Louart, Guillaume
    de La Coussaye, Jean E.
    Jaber, Samir
    Leone, Marc
    Lefrant, Jean-Y
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (09) : 664 - 669
  • [27] Dexmedetomidine Use in Intensive Care Unit Sedation and Postoperative Recovery in Elderly Patients Post-Cardiac Surgery (DIRECT)
    Chitnis, Shruti
    Mullane, Darren
    Brohan, Janette
    Noronha, Andrea
    Paje, Howard
    Grey, Rebecca
    Bhalla, Rishi K.
    Sidhu, Jesse
    Klein, Rael
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (03) : 880 - 892
  • [28] Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysis
    Saugel, Bernd
    Hoppe, Phillip
    Nicklas, Julia Y.
    Kouz, Karim
    Koerner, Annmarie
    Hempell, Julia C.
    Vos, Jaap J.
    Schoen, Gerhard
    Scheeren, Thomas W. L.
    BRITISH JOURNAL OF ANAESTHESIA, 2020, 125 (01) : 25 - 37
  • [29] Comparison of Uncalibrated Arterial Pressure Waveform Analysis with Continuous Thermodilution Cardiac Output Measurements in Patients Undergoing Elective Off-Pump Coronary Artery Bypass Surgery
    Jeong, Yong Bo
    Kim, Tae Hee
    Roh, Young Jin
    Choi, In Cheol
    Suh, Jeong Hun
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (05) : 767 - 771
  • [30] Comparison of cardiac index measurements in intensive care patients using continuous wave vs. pulsed wave echo-Doppler compared to pulse contour cardiac output
    Parulekar, Prashant
    Powys-Lybbe, James
    Bassett, Paul
    Roques, Seb
    Snazelle, Mark
    Millen, Gemma
    Harris, Tim
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2023, 11 (01)