Feasibility of using a depth camera or pressure mat for visual feedback balance training with functional electrical stimulation

被引:4
作者
Lim, Derrick [1 ,2 ]
Pei, William [1 ,2 ]
Lee, Jae W. [1 ,2 ]
Musselman, Kristin E. [2 ,3 ,4 ]
Masani, Kei [1 ,2 ]
机构
[1] Univ Toronto, Inst Biomed Engn, Toronto, ON, Canada
[2] Univ Hlth Network, Toronto Rehabil Inst, KITE, Toronto, ON, Canada
[3] Univ Toronto, Temerty Fac Med, Dept Phys Therapy, Toronto, ON, Canada
[4] Univ Toronto, Rehabil Sci Inst, Temerty Fac Med, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
Functional electrical stimulation; Standing balance; Visual feedback training; Depth camera; SPINAL-CORD-INJURY; STANDING BALANCE; PHYSICAL-THERAPY; REHABILITATION; PEOPLE; BIOFEEDBACK; STROKE; SYSTEM;
D O I
10.1186/s12938-023-01191-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Individuals with incomplete spinal-cord injury/disease are at an increased risk of falling due to their impaired ability to maintain balance. Our research group has developed a closed-loop visual-feedback balance training (VFBT) system coupled with functional electrical stimulation (FES) for rehabilitation of standing balance (FES + VFBT system); however, clinical usage of this system is limited by the use of force plates, which are expensive and not easily accessible. This study aimed to investigate the feasibility of a more affordable and accessible sensor such as a depth camera or pressure mat in place of the force plate. Ten able-bodied participants (7 males, 3 females) performed three sets of four different standing balance exercises using the FES + VFBT system with the force plate. A depth camera and pressure mat collected centre of mass and centre of pressure data passively, respectively. The depth camera showed higher Pearson's correlation (r > 98) and lower root mean squared error (RMSE < 10 mm) than the pressure mat (r > 0.82; RMSE < 4.5 mm) when compared with the force plate overall. Stimulation based on the depth camera showed lower RMSE than that based on the pressure mat relative to the FES + VFBT system. The depth camera shows potential as a replacement sensor to the force plate for providing feedback to the FES + VFBT system.
引用
收藏
页数:17
相关论文
共 42 条
  • [41] Feasibility study of immersive virtual prism adaptation therapy with depth-sensing camera using functional near-infrared spectroscopy in healthy adults
    Cho, Sungmin
    Chang, Won Kee
    Park, Jihong
    Lee, Seung Hyun
    Lee, Jongseung
    Han, Cheol E.
    Paik, Nam-Jong
    Kim, Won-Seok
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [42] Trunk muscle co-activation using functional electrical stimulation modifies center of pressure fluctuations during quiet sitting by increasing trunk stiffness
    Milosevic, Matija
    Masani, Kei
    Wu, Noel
    McConville, Kristiina M. V.
    Popovic, Milos R.
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12