Innovative nanostructured aptasensor for the electrochemical detection of gluten in food samples

被引:12
作者
Tertis, Mihaela [1 ]
Za, Manuela [1 ]
Pusta, Alexandra [1 ,2 ]
Suciu, Maria [3 ,4 ]
Bogdan, Diana [4 ]
Cristea, Cecilia [1 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Analyt Chem, 4 Louis Pasteur St, Cluj Napoca 400349, Romania
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Med Devices, 4 Louis Pasteur St, Cluj Napoca 400349, Romania
[3] Babes Bolyai Univ Cluj Napoca, Biol & Geol Fac, Electron Microscopy Ctr C Craciun, 5-7 Clinicilor Str, Cluj Napoca 400006, Romania
[4] Natl Inst Res & Dev Isotop & Mol Technol, 67-103 Donat St, Cluj Napoca 400293, Romania
关键词
Gluten; Gliadins; Electrochemical aptasensor; In-lab screen-printed electrodes; IMMOBILIZATION; ASSAY;
D O I
10.1016/j.microc.2023.109069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gluten is a protein found in a wide variety of cereals, such as wheat, rye and barley. While important for the food fabrication process, the presence of gluten in these cereals can be dangerous for patients suffering from celiac disease or gluten allergy. Moreover, gluten can be found in trace amounts even in food products that should not theoretically contain it. For this reason, it is important to develop new, fast, and reliable methods for the detection of gluten in food samples. In this work, a nanostructured platform based on graphite and gold was developed, optimized and characterized. The platform was used for the construction of an aptasensor for the selective detection of gliadin, the component of gluten responsible for triggering celiac disease. The aptasensor was able to detect this analyte in a domain of 10-50000 ng/L with a limit of detection of 3.4 ng/L. The aptasensor proved to be sensitive and selective for the target analyte, even in wheat flour samples containing gluten, allowing the detection of gluten up to 10 & mu;g/kg of flour, but also in products from the category of gluten-free products such as gluten-free flour substitute comprised of a mixture of rice flour, carob flour, soy flour and starch and gluten-free breakfast cereals (muesli and breakfast cereals filled with hazelnut cream). Thus, the aptasensor proved useful for applications in food quality control, including for products from the gluten-free category, for which a maximum gluten content of 20 ppm (20 mg gluten/kg of product) is accepted.
引用
收藏
页数:10
相关论文
共 50 条
[31]   A Polyamidoamine-Based Electrochemical Aptasensor for Sensitive Detection of Ochratoxin A [J].
Chen, Xiujin ;
Gao, Dong ;
Chen, Jiaqi ;
Wang, Xueqing ;
Peng, Chifang ;
Gao, Hongli ;
Wang, Yao ;
Li, Zhaozhou ;
Niu, Huawei .
BIOSENSORS-BASEL, 2023, 13 (11)
[32]   A homogeneous electrochemical aptasensor based on DNA assembly for zearalenone detection [J].
Qu, Chenling ;
Xin, Lingkun ;
Yu, Songcheng ;
Wei, Min .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (10) :1998-2005
[33]   Electrochemical enzyme biosensors based on calcium phosphate materials for tyramine detection in food samples [J].
Lopez, Marta Sanchez-Paniagua ;
Redondo-Gomez, Esther ;
Lopez-Ruiz, Beatriz .
TALANTA, 2017, 175 :209-216
[34]   Development and in-house validation of a competitive ELISA for the quantitative detection of gluten in food [J].
Sajic, Nermin ;
Oplatowska-Stachowiak, Michalina ;
Streppel, Lucia ;
Drijfhout, Jan-Wouter ;
Salden, Martin ;
Koning, Frits .
FOOD CONTROL, 2017, 80 :401-410
[35]   Fluorescence aptasensor for Ochratoxin A in food samples based on hyperbranched rolling circle amplification [J].
Zhang, Ying ;
Yang, Linlin ;
Lin, Cuiying ;
Guo, Longhua ;
Qiu, Bin ;
Lin, Zhenyu ;
Chen, Guonan .
ANALYTICAL METHODS, 2015, 7 (15) :6109-6113
[36]   A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples [J].
Zhang, Guilan ;
Zhu, Chao ;
Huang, Yafei ;
Yan, Jiao ;
Chen, Ailiang .
MOLECULES, 2018, 23 (02)
[37]   A SWCNT based aptasensor system for antibiotic oxytetracycline detection in water samples [J].
Yildirim-Tirgil, Nimet ;
Lee, Jinyoung ;
Cho, Hanchul ;
Lee, HeaYeon ;
Somu, Sivasubramanian ;
Busnaina, Ahmed ;
Gu, April Z. .
ANALYTICAL METHODS, 2019, 11 (20) :2692-2699
[38]   An ultrasensitive electrochemical aptasensor using Tyramide-assisted enzyme multiplication for the detection of Staphylococcus aureus [J].
Nguyen, Thi Thanh-Qui ;
Gu, Man Bock .
BIOSENSORS & BIOELECTRONICS, 2023, 228
[39]   Ultrasensitive label-free homogeneous electrochemical aptasensor based on sandwich structure for thrombin detection [J].
Zhang, Yaxing ;
Xia, Jianfei ;
Zhang, Feifei ;
Wang, Zonghua ;
Liu, Qingyun .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 267 :412-418
[40]   Current Trends in Electrochemical Aptasensor for Tumor- Associated Growth Factor Receptor Detection in Serum [J].
Han, Li .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06)