Agreement of Corneal Diameter and Anterior Chamber Depth Measurements with the IOLMaster 500 and the IOLMaster 700 Optical Biometers in Myopic Eyes

被引:4
作者
Tana-Rivero, Pedro [1 ,2 ]
Tello-Elordi, Cristina [1 ]
Orts-Vila, Paz [1 ]
Tana-Sanz, Pedro [1 ]
Tana-Sanz, Santiago [1 ]
机构
[1] Oftalvist Alicante, Cataract Dept, Alicante, Spain
[2] Oftalvist Alicante, Cataract Dept, C Angel Lozano N 11, Alicante 03001, Spain
关键词
anterior chamber depth; white-to-white; IOLMaster; 500; 700; optical biometry; INTRAOCULAR-LENS POWER; PRECISION REPEATABILITY; REPRODUCIBILITY;
D O I
10.2147/OPTH.S409132
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the agreement in automated corneal diameter (CD) and anterior chamber depth (ACD, measured from corneal epithelium to lens) distances measurements between the IOLMaster 500 and 700 optical biometers in myopic eyes.Methods: One hundred and sixteen eyes of 116 myopic patients aged between 21 to 60 years were included in this study. Measurements of CD and ACD distances were taken with each biometer for all patients in the same session. A t-test and a p-value less than 0.05 was considered statistically significant when the measurements were compared. The agreement between biometers was studied by applying a Bland-Altman analysis.Results: The mean CD values obtained using the IOLMaster 500 and 700 biometers were 12.26 +/- 0.35 mm and 12.13 +/- 0.34 mm, respectively. The mean ACD distance values were 3.61 +/- 0.29 mm and 3.62 +/- 0.31, for the IOLMaster 500 and 700 biometers, respectively. There were statistically significant differences between the two devices only for CD measurements (p<0.001), but not for ACD measurements (p=0.26). The limits of agreement obtained were wide in both types of measurements, being 0.422 mm for the CD distance and 0.389 mm for the ACD distance.Conclusion: There were statistically significant differences between the IOLMaster 500 and 700 biometers regarding CD but not in ACD measurements in healthy myopic eyes. These differences could be clinically significant in some cases. According to these results, medical judgement should be used to assess whether the two devices could be used interchangeably for CD and ACD measurements during the clinical practice.
引用
收藏
页码:1245 / 1253
页数:9
相关论文
共 16 条
[11]   Distribution of White-to-White Corneal Diameter and Anterior Chamber Depth in Chinese Myopic Patients [J].
Xu, Guihua ;
Wu, Guanrong ;
Du, Zijing ;
Zhu, Shanqing ;
Guo, Yunxiang ;
Yu, Honghua ;
Hu, Yijun .
FRONTIERS IN MEDICINE, 2021, 8
[12]   Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and Pentacam [J].
Yazici, Ahmet Taylan ;
Bozkurt, Ercument ;
Alagoz, Cengiz ;
Alagoz, Nese ;
Pekel, Gokhan ;
Kaya, Vedat ;
Yilmaz, Omer Faruk .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) :127-133
[13]   Repeatability, reproducibility, and agreement of central anterior chamber depth measurements in pseudophakic and phakic eyes: Optical coherence tomography versus ultrasound biomicroscopy [J].
Zhang, Qi ;
Jin, Wanqing ;
Wang, Qinmei .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06) :941-946
[14]   Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes [J].
Luft, Nikolaus ;
Hirnschall, Nino ;
Farrokhi, Sanaz ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08) :1678-1684
[15]   Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation [J].
Muriël Doors ;
Lars P. J. Cruysberg ;
Tos T. J. M. Berendschot ;
John de Brabander ;
Frenne Verbakel ;
Carroll A. B. Webers ;
Rudy M. M. A. Nuijts .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 :1139-1146
[16]   Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation [J].
Doors, Muriel ;
Cruysberg, Lars P. J. ;
Berendschot, Tos T. J. M. ;
de Brabander, John ;
Verbakel, Frenne ;
Webers, Carroll A. B. ;
Nuijts, Rudy M. M. A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (08) :1139-1146