Noise Reduction Using Singular Value Decomposition with Jensen-Shannon Divergence for Coronary Computed Tomography Angiography

被引:0
|
作者
Kasai, Ryosuke [1 ]
Otsuka, Hideki [1 ]
机构
[1] Tokushima Univ, Inst Biomed Sci, Dept Med Imaging, Nucl Med, 3-18-15 Kuramoto, Tokushima 7708509, Japan
关键词
coronary computed tomography angiography; singular value decomposition; Jensen-Shannon divergence; noise reduction; IMAGE-RECONSTRUCTION; INFORMATION;
D O I
10.3390/diagnostics13061111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary computed tomography angiography (CCTA) is widely used due to its improvements in computed tomography (CT) diagnostic performance. Unlike other CT examinations, CCTA requires shorter rotation times of the X-ray tube, improving the temporal resolution and facilitating the imaging of the beating heart in a stationary state. However, reconstructed CT images, including those of the coronary arteries, contain insufficient X-ray photons and considerable noise. In this study, we introduce an image-processing technique for noise reduction using singular value decomposition (SVD) for CCTA images. The threshold of SVD was determined on the basis of minimization of Jensen-Shannon (JS) divergence. Experiments were performed with various numerical phantoms and varying levels of noise to reduce noise in clinical CCTA images using the determined threshold value. The numerical phantoms produced 10% higher-quality images than the conventional noise reduction method when compared on a quantitative SSIM basis. The threshold value determined by minimizing the JS-divergence was found to be useful for efficient noise reduction in actual clinical images, depending on the level of noise.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A METHOD FOR NOISE REDUCTION IN SPEECH SIGNAL BASED ON SINGULAR VALUE DECOMPOSITION AND GENETIC ALGORITHM
    Nazari, Bahare
    Sarkrni, Seyed M. Ahadi
    Karimi, Paiam
    EUROCON 2009: INTERNATIONAL IEEE CONFERENCE DEVOTED TO THE 150 ANNIVERSARY OF ALEXANDER S. POPOV, VOLS 1- 4, PROCEEDINGS, 2009, : 102 - 107
  • [22] Prognostic value of SYNTAX score based on coronary computed tomography angiography
    Suh, Young Joo
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Hur, Jin
    Kima, Young Jin
    Lee, Hye Sun
    Hong, Sae Rom
    Im, Dong Jin
    Kim, Yun Jung
    Park, Chul Hwan
    Kim, Tae Hoon
    Yoo, Kyung-Jong
    Choi, Byoung Wook
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 199 : 460 - 466
  • [23] Development of an advanced noise reduction method for vibration analysis based on singular value decomposition
    Yang, WX
    Tse, PW
    NDT & E INTERNATIONAL, 2003, 36 (06) : 419 - 432
  • [24] Risk assessment of an oil depot using the improved multi-sensor fusion approach based on the cloud model and the belief Jensen-Shannon divergence
    Xie, Shuyi
    Chen, Yinuo
    Dong, Shaohua
    Zhang, Guangyu
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2020, 67
  • [25] Fat volume measurements as a predictor of image noise in coronary computed tomography angiography
    Abazid, Rami M.
    Smettei, Osama A.
    Almeman, Ahmad
    Sayed, Sawsan
    Alsaqqa, Hanaa
    Abdelmageed, Salma M.
    Alharbi, Fahad J.
    Alhabib, Abdullah M.
    Al-Mallah, Mouaz H.
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2019, 31 (01) : 32 - 40
  • [26] Seismic Random Noise Attenuation in the Laplace Domain Using Singular Value Decomposition
    Ha, Wansoo
    Shin, Changsoo
    IEEE ACCESS, 2021, 9 : 62029 - 62037
  • [27] Diagnostic and Prognostic Value of Coronary Computed Tomography Angiography in Patients with Severe Calcification
    Diaz-Anton, Belen
    Solis, Jorge
    Diaz Morales, Roberto
    Lopez-Melgar, Beatriz
    Barrio, Patricia
    Moreno, Andrea
    Unzue, Leire
    Alvarez-Vieitez, Antonio
    Medina, Juan
    Garcia, Eulogio
    Parra Jimenez, Francisco Javier
    Fernandez-Friera, Leticia
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2021, 14 (01) : 131 - 139
  • [28] Diagnostic and Prognostic Value of Coronary Computed Tomography Angiography in Patients with Severe Calcification
    Belén Díaz-Antón
    Jorge Solís
    Roberto Díaz Morales
    Beatriz López-Melgar
    Patricia Barrio
    Andrea Moreno
    Leire Unzué
    Antonio Alvarez-Vieitez
    Juan Medina
    Eulogio García
    Francisco Javier Parra Jiménez
    Leticia Fernández-Friera
    Journal of Cardiovascular Translational Research, 2021, 14 : 131 - 139
  • [29] Noise Reduction using Wavelet Transform and Singular Vector Decomposition
    Patil, Rajesh
    ELEVENTH INTERNATIONAL CONFERENCE ON COMMUNICATION NETWORKS, ICCN 2015/INDIA ELEVENTH INTERNATIONAL CONFERENCE ON DATA MINING AND WAREHOUSING, ICDMW 2015/NDIA ELEVENTH INTERNATIONAL CONFERENCE ON IMAGE AND SIGNAL PROCESSING, ICISP 2015, 2015, 54 : 849 - 853
  • [30] Effects of combining multiple dose reduction techniques on coronary computed tomography angiography
    Hu, Xiao-Lu
    Huang, Pei-Kai
    Zhang, Meng
    Chen, Jun
    Xiao, Meng-Qiang
    WORLD JOURNAL OF RADIOLOGY, 2023, 15 (02): : 32 - 41