Single and multi-frame auto-calibration for 3D endoscopy with differential rendering

被引:3
作者
Furukawa, Ryo [1 ]
Sagawa, Ryusulce [2 ]
Oka, Shiro [3 ]
Tanaka, Shinji [3 ]
Kawasaki, Hiroshi [4 ]
机构
[1] Kindai Univ, Higashiosaka, Osaka, Japan
[2] AIST, Tokyo, Japan
[3] Hiroshima Univ, Higashihiroshima, Japan
[4] Kyushu Univ, Fukuoka, Japan
来源
2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC | 2023年
关键词
INVASIVE SURGERY; SYSTEM;
D O I
10.1109/EMBC40787.2023.10340381
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The use of 3D measurement in endoscopic images offers practicality in cancer diagnosis, computer-assisted interventions, and making annotations for machine learning training data. An effective approach is the implementation of an active stereo system, using a micro-sized pattern projector and an endoscope camera, which has been intensively developed. One open problem for such a system is the necessity of strict and complex calibration of the projector-camera system to precisely recover the shapes. Moreover, since the head of an endoscope should have enough elasticity to avoid harming target objects, the positions of the pattern projector cannot be tightly fixed to the head, resulting in limited accuracy. A straightforward approach to the problem is applying auto-calibration. However, it requires special markers in the pattern or a highly accurate initial position for stable calibration, which is impractical for real operation. In the paper, we propose a novel autocalibration method based on differential rendering techniques, which are recently proposed and drawing wide attention. To apply the method to an endoscopic system, where a diffractive optical element (DOE) is used, we propose a technique to simultaneously estimate the focal length of the DOE as well as the extrinsic parameters between a projector and a camera. We also propose a multi-frame optimization algorithm to jointly optimize the intrinsic and extrinsic parameters, relative pose between frames, and the entire shape. Clinical relevance- One-shot endoscopic measurement of depth information is a practical solution for cancer diagnosis, computer-assisted interventions, and making annotations for machine learning training data.
引用
收藏
页数:5
相关论文
共 21 条
  • [1] [Anonymous], 2010, MICCAI
  • [2] [Anonymous], 2020, EMBC
  • [3] Besl P., 1992, International Society for Optics and Photonics, DOI DOI 10.1117/12.57955
  • [4] SLAM-based dense surface reconstruction in monocular Minimally Invasive Surgery and its application to Augmented Reality
    Chen, Long
    Tang, Wen
    John, Nigel W.
    Wan, Tao Ruan
    Zhang, Jian Jun
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 158 : 135 - 146
  • [5] Curless B., 1996, Computer Graphics Proceedings. SIGGRAPH '96, P303, DOI 10.1145/237170.237269
  • [6] Uncalibrated multiple image stereo system with arbitrarily movable camera and projector for wide range scanning
    Furukawa, R
    Kawasaki, H
    [J]. FIFTH INTERNATIONAL CONFERENCE ON 3-D DIGITAL IMAGING AND MODELING, PROCEEDINGS, 2005, : 302 - 309
  • [7] Simultaneous shape and camera-projector parameter estimation for 3D endoscopic system using CNN-based grid-oneshot scan
    Furukawa, Ryo
    Nagamatsu, Genki
    Oka, Shiro
    Kotachi, Takahiro
    Okamoto, Yuki
    Tanaka, Shinji
    Kawasaki, Hiroshi
    [J]. HEALTHCARE TECHNOLOGY LETTERS, 2019, 6 (06) : 249 - 254
  • [8] Endoscopic Laser Surface Scanner for Minimally Invasive Abdominal Surgeries
    Geurten, Jordan
    Xia, Wenyao
    Jayarathne, Uditha
    Peters, Terry M.
    Chen, Elvis C. S.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT IV, 2018, 11073 : 143 - 150
  • [9] Henderson P., 2018, BMVC, P1
  • [10] Neural 3D Mesh Renderer
    Kato, Hiroharu
    Ushiku, Yoshitaka
    Harada, Tatsuya
    [J]. 2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2018, : 3907 - 3916