Thermal and optical investigations of various transparent wall configurations and building integrated photovoltaic for energy savings in buildings

被引:23
|
作者
Marei, Youssef A. [1 ,2 ]
Emam, Mohamed [1 ,3 ]
Ahmed, Mohamed E. A. E. [1 ]
Attia, Ahmed A. A. [1 ]
Abdelrahman, M. A. [1 ]
机构
[1] Benha Univ, Shoubra Fac Engn, Mech Engn Dept, Combust & Energy Technol Lab, Banha 11629, Egypt
[2] Badr Univ Cairo BUC, Fac Engn & Technol, Mech Engn Dept, Cairo 11829, Cairo, Egypt
[3] Egypt Japan Univ Sci & Technol E JUST, Dept Energy Resources Engn, Alexandria 21934, Egypt
关键词
Building energy saving; Building integrated photovoltaic; Facade; Cadmium telluride; Lighting system; Cooling loads; CFD simulation; SEMITRANSPARENT PV; BIPV SYSTEM; SOLAR-CELL; PERFORMANCE; WINDOW;
D O I
10.1016/j.enconman.2023.117817
中图分类号
O414.1 [热力学];
学科分类号
摘要
The growing global attention on energy consumption in buildings, along with the harmful effects of carbon dioxide emissions on climate change, has recently heightened efforts on sustainability and energy savings in buildings. As a result, the search for high thermal resistance walls, as well as the development of integrated photovoltaic technology with front glass walls to save energy in buildings, is an important and promising topic. The current study investigates and compares the energy-saving capabilities of four building transparent wall configurations: basic glass, facade, basic glass integrated with photovoltaics, and facade integrated with photovoltaics at different ambient temperatures, wind speeds, and solar radiation. The study also introduces a comprehensive three-dimensional heat transfer and electrical model that combines a Steady-State Thermal solution with the ANSYS mechanical solver and a fluid flow solution with the ANSYS Fluent solver to simulate the full layers of Cadmium Telluride solar cells, transparent walls, and the air conditioning room. Each model was subjected to a full-day simulation using Egypt weather conditions in the summer season to evaluate the efficacy in terms of saving artificial lighting loads, thermal loads for air conditioning, daily electricity generation from Cadmium Telluride solar cells, and total energy savings throughout the day. According to the findings, the facade integrated with photovoltaics and basic glass integrated with photovoltaics configurations deliver about 394 Wh/ m2 of electrical energy to the building daily. Furthermore, when air conditioning and lighting loads, as well as solar cell productivity, are considered, the facade, basic glass integrated with photovoltaics, and facade integrated with photovoltaics configurations save 46.9%, 31.5%, and 79.3% of total electricity consumption, respectively, when compared to the basic glass wall.
引用
收藏
页数:23
相关论文
共 41 条
  • [31] Energy and optical analysis of photovoltaic thermal integrated with rotary linear curved Fresnel lens inside a Chinese solar greenhouse
    Wu, Gang
    Yang, Qichang
    Zhang, Yi
    Fang, Hui
    Feng, Chanqing
    Zheng, Hongfei
    ENERGY, 2020, 197
  • [32] Aesthetically Appealing Building Integrated Photovoltaic Systems for Net-Zero Energy Buildings. Current Status, Challenges, and Future Developments-A Review
    Basher, Mohammad Khairul
    Nur-E-Alam, Mohammad
    Rahman, Md Momtazur
    Alameh, Kamal
    Hinckley, Steven
    BUILDINGS, 2023, 13 (04)
  • [33] Energy optimization of building-integrated photovoltaic for load shifting and grid robustness in high-rise buildings based on optimum planned grid output
    Liu, Jia
    Pan, Zhongjie
    Huang, Huakun
    Wu, Huijun
    ENERGY CONVERSION AND MANAGEMENT, 2025, 324
  • [34] Two-Stage Lifecycle Energy Optimization of Mid-Rise Residential Buildings with Building-Integrated Photovoltaic and Alternative Composite Facade Materials
    Ansah, Mark Kyeredey
    Chen, Xi
    Yang, Hongxing
    BUILDINGS, 2021, 11 (12)
  • [35] Experimental and numerical investigation of integrated system between cooled photovoltaic and wall-inserted PCM/FOM thermal energy storage box
    Murtadha, Talib K.
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [36] Quasi-dynamic energy performance analysis of building integrated photovoltaic thermal double skin facade for middle eastern climate case
    Shakouri, Mahdi
    Ghadamian, Hossein
    Noorpoor, Alireza
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [37] Comparative energy, exergy, environmental, exergoeconomic, and enviroeconomic analysis of building integrated photovoltaic/thermal, earth-air heat exchanger, and hybrid systems
    Shahsavar, Amin
    Talebizadehsardari, Pouyan
    Arici, Muslum
    JOURNAL OF CLEANER PRODUCTION, 2022, 362
  • [38] Multi-objective optimization and evaluation of the building-integrated photovoltaic/thermal-energy pile ground source heat pump system
    Wang, Fang
    You, Tian
    Cui, Hongzhi
    APPLIED ENERGY, 2024, 371
  • [39] Durum-Wheat Straw Bales for Thermal Insulation of Buildings: Findings from a Comparative Energy Analysis of a Set of Wall-Composition Samples on the Building Scale
    Palladino, Domenico
    Scrucca, Flavio
    Calabrese, Nicolandrea
    Barberio, Grazia
    Ingrao, Carlo
    ENERGIES, 2021, 14 (17)
  • [40] Energy analysis and multi-objective optimization of a novel exhaust air heat recovery system consisting of an air-based building integrated photovoltaic/thermal system and a thermal wheel
    Khanmohammadi, Shoaib
    Shahsavar, Amin
    ENERGY CONVERSION AND MANAGEMENT, 2018, 172 : 595 - 610