摘要
Whisky adulteration is a prevalent practice driven by the high cost of these beverages. Counterfeiters commonly dilute whisky with less expensive alcoholic beverages, water, food additives, drugs or pharmaceuticals. Paracetamol (PAR), an analgesic drug that mitigates hangovers and headaches, is commonly used to adulterate whisky. Currently, the primary method for quantifying PAR levels is high-performance liquid chromatography, but this technique is both time consuming and usually generates more residues. In this context, the utilization of miniaturized and portable analytical devices becomes imperative for conducting point-of-care/need analyses. These devices offer several advantages, including portability, user-friendliness, low cost, and minimal material wastage. This study proposes the selective distance-based PAR quantification on whisky samples using a paper-based microfluidic analytical device (mu PAD). Colorimetric detection on paper-based platforms offers great benefits such as affordability, portability, and the ability to detect PAR without complicated instrumentation. The optimal detection conditions were achieved by introducing 5 mu L of a mixture containing 7.5 mmol L-1 of Fe(iii) and K3[Fe(CN)6] into the detection zone, along with 12 mu L of whisky samples into the sample zone. The method exhibited linear behavior within the concentration range from 15 to 120 mg L-1, with a determination coefficient of 0.998. PAR was quantified in adulterated samples. The results obtained with the paper-based devices were compared with a referenced method, and no significant differences were observed at a confidence level of 95%. The mu PAD allowed to determine ca. 1 drop of pharmaceutical medicine PAR of 200 mg mL-1 in 1 L of solution, demonstrating excellent sensitivity. This method offers cost-effective and rapid analysis, reducing the consumption of samples, reagents, and wastes. Consequently, it could be considered a viable and portable alternative for analyzing beverages at criminal scenes, customs, and police operations, thereby enhancing the field of forensics. Whisky adulteration is a prevalent practice driven by the high cost of these beverages.
引用
收藏
页码:33 / 39
页数:8
相关论文
共 50 条
  • [41] Recent Developments and Applications of Microfluidic Paper-Based Analytical Devices for the Detection of Biological and Chemical Hazards in Foods: A Critical Review
    Alahmad, Waleed
    Varanusupakul, Puttaruksa
    Varanusupakul, Pakorn
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2023, 53 (02) : 233 - 252
  • [42] Microfluidic paper-based analytical devices (μPADs) for fast and ultrasensitive sensing of biomarkers and monitoring of diseases
    Abdollahi-Aghdam, Abdollah
    Majidi, Mir Reza
    Omidi, Yadollah
    [J]. BIOIMPACTS, 2018, 8 (04) : 237 - 240
  • [43] Geometrical Alignment of Multiple Fabrication Steps for Rapid Prototyping of Microfluidic Paper-Based Analytical Devices
    Rahbar, Mohammad
    Nesterenko, Pavel N.
    Paull, Brett
    Macka, Mirek
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (22) : 11918 - 11923
  • [44] Microfluidic paper-based analytical devices for environmental analysis of soil, air, ecology and river water
    Kung, Chia-Te
    Hou, Chih-Yao
    Wang, Yao-Nan
    Fu, Lung-Ming
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301
  • [45] Rational selection of substrates to improve color intensity and uniformity on microfluidic paper-based analytical devices
    Evans, Elizabeth
    Moreira Gabriel, Ellen Flavia
    Tomazelli Coltro, Wendell Karlos
    Garcia, Carlos D.
    [J]. ANALYST, 2014, 139 (09) : 2127 - 2132
  • [46] Distance-based paper analytical devices integrated with molecular imprinted polymers for Escherichia coli quantification
    Khachornsakkul, Kawin
    Zeng, Wenxin
    Sonkusale, Sameer
    [J]. MICROCHIMICA ACTA, 2024, 191 (05)
  • [47] Microfluidic Paper-Based Analytical Device for Aerosol Oxidative Activity
    Sameenoi, Yupaporn
    Panymeesamer, Pantila
    Supalakorn, Natcha
    Koehler, Kirsten
    Chailapakul, Orawon
    Henry, Charles S.
    Volckens, John
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (02) : 932 - 940
  • [48] Increasing the packing density of assays in paper-based microfluidic devices
    Dabbagh, Sajjad Rahmani
    Becher, Elaina
    Ghaderinezhad, Fariba
    Havlucu, Hayati
    Ozcan, Oguzhan
    Ozkan, Mehmed
    Yetisen, Ali Kemal
    Tasoglu, Savas
    [J]. BIOMICROFLUIDICS, 2021, 15 (01)
  • [49] Paper-based microfluidic point-of-care diagnostic devices
    Yetisen, Ali Kemal
    Akram, Muhammad Safwan
    Lowe, Christopher R.
    [J]. LAB ON A CHIP, 2013, 13 (12) : 2210 - 2251
  • [50] Use of multiple colorimetric indicators for paper-based microfluidic devices
    Dungchai, Wijitar
    Chailapakul, Orawon
    Henry, Charles S.
    [J]. ANALYTICA CHIMICA ACTA, 2010, 674 (02) : 227 - 233