Distance-based detection of paracetamol in microfluidic paper-based analytical devices for forensic application

被引:3
作者
Moreira, Nikaele S. [1 ]
Pinheiro, Kemilly M. P. [1 ]
Sousa, Lucas R. [1 ,2 ]
Garcia, Gabriel D. S. [1 ]
Figueredo, Federico [2 ]
Coltro, Wendell K. T. [1 ,2 ,3 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, GO, Brazil
[2] Univ Buenos Aires UBA, Fac Ciencias Exactas & Nat, Dept Quim Biol IQUIBICEN, Lab Biosensores & Bioanal LABB,CONICET, Pabellon 2, Ciudad Univ, Buenos Aires, Argentina
[3] Inst Nacl Ciencia & Tecnol Bioanalit, BR-13084971 Campinas, SP, Brazil
关键词
COLORIMETRIC DETECTION; QUANTIFICATION; ADULTERANTS; CAFFEINE; COCAINE; DESIGN; DRUGS;
D O I
10.1039/d3ay01739g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Whisky adulteration is a prevalent practice driven by the high cost of these beverages. Counterfeiters commonly dilute whisky with less expensive alcoholic beverages, water, food additives, drugs or pharmaceuticals. Paracetamol (PAR), an analgesic drug that mitigates hangovers and headaches, is commonly used to adulterate whisky. Currently, the primary method for quantifying PAR levels is high-performance liquid chromatography, but this technique is both time consuming and usually generates more residues. In this context, the utilization of miniaturized and portable analytical devices becomes imperative for conducting point-of-care/need analyses. These devices offer several advantages, including portability, user-friendliness, low cost, and minimal material wastage. This study proposes the selective distance-based PAR quantification on whisky samples using a paper-based microfluidic analytical device (mu PAD). Colorimetric detection on paper-based platforms offers great benefits such as affordability, portability, and the ability to detect PAR without complicated instrumentation. The optimal detection conditions were achieved by introducing 5 mu L of a mixture containing 7.5 mmol L-1 of Fe(iii) and K3[Fe(CN)6] into the detection zone, along with 12 mu L of whisky samples into the sample zone. The method exhibited linear behavior within the concentration range from 15 to 120 mg L-1, with a determination coefficient of 0.998. PAR was quantified in adulterated samples. The results obtained with the paper-based devices were compared with a referenced method, and no significant differences were observed at a confidence level of 95%. The mu PAD allowed to determine ca. 1 drop of pharmaceutical medicine PAR of 200 mg mL-1 in 1 L of solution, demonstrating excellent sensitivity. This method offers cost-effective and rapid analysis, reducing the consumption of samples, reagents, and wastes. Consequently, it could be considered a viable and portable alternative for analyzing beverages at criminal scenes, customs, and police operations, thereby enhancing the field of forensics. Whisky adulteration is a prevalent practice driven by the high cost of these beverages.
引用
收藏
页码:33 / 39
页数:8
相关论文
共 50 条
  • [31] Selective Distance-Based K+ Quantification on Paper-Based Microfluidics
    Gerold, Chase T.
    Bakker, Eric
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2018, 90 (07) : 4894 - 4900
  • [32] Microfluidic paper-based analytical soft actuators (μPAC)
    Yoshida, Koki
    Tanakinoue, Masahiro
    Onoe, Hiroaki
    Hashimoto, Michinao
    LAB ON A CHIP, 2025,
  • [33] Paper-based analytical devices for environmental analysis
    Meredith, Nathan A.
    Quinn, Casey
    Cate, David M.
    Reilly, Thomas H., III
    Volckens, John
    Henry, Charles S.
    ANALYST, 2016, 141 (06) : 1874 - 1887
  • [34] Microfluidic flow modulation with digitized sizing pattern in Xuan paper-based analytical devices
    Lizama, Jose H.
    Tseng, Hsiu-Yang
    Shen, Yi-Wei
    Chen, Chiu-Jen
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (09) : 7171 - 7181
  • [35] Simultaneous analysis of multiple adulterants in milk using microfluidic paper-based analytical devices
    Guinati, Barbara G. S.
    Sousa, Lucas R.
    Oliveira, Karoliny A.
    Coltro, Wendell K. T.
    ANALYTICAL METHODS, 2021, 13 (44) : 5383 - 5390
  • [36] Programmable Paper-Based Microfluidic Devices for Biomarker Detections
    Soum, Veasna
    Park, Sooyong
    Brilian, Albertus Ivan
    Kwon, Oh-Sun
    Shin, Kwanwoo
    MICROMACHINES, 2019, 10 (08)
  • [37] Distance-Based Detection of Ag+ with Gold Nanoparticles-Coated Microfluidic Paper
    Yu Zhang
    Yu-Long Li
    Shu-Hua Cui
    Cong-Ying Wen
    Peng Li
    Jian-Feng Yu
    Shi-Ming Tang
    Jing-Bin Zeng
    Journal of Analysis and Testing, 2021, 5 : 11 - 18
  • [38] Distance-Based Detection of Ag+ with Gold Nanoparticles-Coated Microfluidic Paper
    Zhang, Yu
    Li, Yu-Long
    Cui, Shu-Hua
    Wen, Cong-Ying
    Li, Peng
    Yu, Jian-Feng
    Tang, Shi-Ming
    Zeng, Jing-Bin
    JOURNAL OF ANALYSIS AND TESTING, 2021, 5 (01) : 11 - 18
  • [39] Paper-based analytical devices for point-of-need applications
    Pradela-Filho, Lauro A.
    Veloso, William B.
    Arantes, Iana V. S.
    Gongoni, Juliana L. M.
    de Farias, Davi M.
    Araujo, Diele A. G.
    Paixao, Thiago R. L. C.
    MICROCHIMICA ACTA, 2023, 190 (05)
  • [40] Open software platform for automated analysis of paper-based microfluidic devices
    Parker, Rayleigh W.
    Wilson, Daniel J.
    Mace, Charles R.
    SCIENTIFIC REPORTS, 2020, 10 (01)