Distance-based detection of paracetamol in microfluidic paper-based analytical devices for forensic application

被引:3
作者
Moreira, Nikaele S. [1 ]
Pinheiro, Kemilly M. P. [1 ]
Sousa, Lucas R. [1 ,2 ]
Garcia, Gabriel D. S. [1 ]
Figueredo, Federico [2 ]
Coltro, Wendell K. T. [1 ,2 ,3 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, GO, Brazil
[2] Univ Buenos Aires UBA, Fac Ciencias Exactas & Nat, Dept Quim Biol IQUIBICEN, Lab Biosensores & Bioanal LABB,CONICET, Pabellon 2, Ciudad Univ, Buenos Aires, Argentina
[3] Inst Nacl Ciencia & Tecnol Bioanalit, BR-13084971 Campinas, SP, Brazil
关键词
COLORIMETRIC DETECTION; QUANTIFICATION; ADULTERANTS; CAFFEINE; COCAINE; DESIGN; DRUGS;
D O I
10.1039/d3ay01739g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Whisky adulteration is a prevalent practice driven by the high cost of these beverages. Counterfeiters commonly dilute whisky with less expensive alcoholic beverages, water, food additives, drugs or pharmaceuticals. Paracetamol (PAR), an analgesic drug that mitigates hangovers and headaches, is commonly used to adulterate whisky. Currently, the primary method for quantifying PAR levels is high-performance liquid chromatography, but this technique is both time consuming and usually generates more residues. In this context, the utilization of miniaturized and portable analytical devices becomes imperative for conducting point-of-care/need analyses. These devices offer several advantages, including portability, user-friendliness, low cost, and minimal material wastage. This study proposes the selective distance-based PAR quantification on whisky samples using a paper-based microfluidic analytical device (mu PAD). Colorimetric detection on paper-based platforms offers great benefits such as affordability, portability, and the ability to detect PAR without complicated instrumentation. The optimal detection conditions were achieved by introducing 5 mu L of a mixture containing 7.5 mmol L-1 of Fe(iii) and K3[Fe(CN)6] into the detection zone, along with 12 mu L of whisky samples into the sample zone. The method exhibited linear behavior within the concentration range from 15 to 120 mg L-1, with a determination coefficient of 0.998. PAR was quantified in adulterated samples. The results obtained with the paper-based devices were compared with a referenced method, and no significant differences were observed at a confidence level of 95%. The mu PAD allowed to determine ca. 1 drop of pharmaceutical medicine PAR of 200 mg mL-1 in 1 L of solution, demonstrating excellent sensitivity. This method offers cost-effective and rapid analysis, reducing the consumption of samples, reagents, and wastes. Consequently, it could be considered a viable and portable alternative for analyzing beverages at criminal scenes, customs, and police operations, thereby enhancing the field of forensics. Whisky adulteration is a prevalent practice driven by the high cost of these beverages.
引用
收藏
页码:33 / 39
页数:8
相关论文
共 50 条
  • [21] Microfluidic paper-based analytical devices with instrument-free detection and miniaturized portable detectors
    Kaneta, Takashi
    Alahmad, Waleed
    Varanusupakul, Pakorn
    APPLIED SPECTROSCOPY REVIEWS, 2019, 54 (02) : 117 - 141
  • [22] Microfluidic paper-based devices for bioanalytical applications
    Santhiago, Murilo
    Nery, Emilia W.
    Santos, Glauco P.
    Kubota, Lauro T.
    BIOANALYSIS, 2014, 6 (01) : 89 - 106
  • [23] Recent Developments in Paper-Based Microfluidic Devices
    Cate, David M.
    Adkins, Jaclyn A.
    Mettakoonpitak, Jaruwan
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2015, 87 (01) : 19 - 41
  • [24] Distance versus Capillary Flow Dynamics-Based Detection Methods on a Microfluidic Paper-Based Analytical Device (μPAD)
    Chung, Soo
    Jennings, Christian M.
    Yoon, Jeong-Yeol
    CHEMISTRY-A EUROPEAN JOURNAL, 2019, 25 (57) : 13070 - 13077
  • [25] Boron Doped Diamond Paste Electrodes for Microfluidic Paper-Based Analytical Devices
    Nantaphol, Siriwan
    Channon, Robert B.
    Kondo, Takeshi
    Siangproh, Weena
    Chailapakul, Orawon
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2017, 89 (07) : 4100 - 4107
  • [26] Design considerations for reducing sample loss in microfluidic paper-based analytical devices
    Nguyen, Michael P.
    Meredith, Nathan A.
    Kelly, Sydney P.
    Henry, Charles S.
    ANALYTICA CHIMICA ACTA, 2018, 1017 : 20 - 25
  • [27] A novel combination of quick response code and microfluidic paper-based analytical devices for rapid and quantitative detection
    Wang, Tengfei
    Xu, Guangning
    Wu, Wenyuan
    Wang, Xiaoying
    Chen, Xueliang
    Zhou, Shumin
    You, Fan
    BIOMEDICAL MICRODEVICES, 2018, 20 (03)
  • [28] Microfluidic Paper-Based Analytical Devices for the Determination of Food Contaminants: Developments and Applications
    Wang, Minglu
    Cui, Jiarui
    Wang, Ying
    Yang, Liu
    Jia, Zhenzhen
    Gao, Chuanjie
    Zhang, Hongyan
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2022, 70 (27) : 8188 - 8206
  • [29] Colorimetric Detection of Alkaline Phosphatase on Microfluidic Paper-based Analysis Devices
    Chen Xi
    Chen Jin
    Zhang Hui-Yan
    Wang Fu-Bing
    Wang Fang-Fang
    Ji Xing-Hu
    He Zhi-Ke
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (04) : 591 - 596
  • [30] Distance-Based Detection of Ag~+ with Gold Nanoparticles-Coated Microfluidic Paper
    Yu Zhang
    Yu-Long Li
    Shu-Hua Cui
    Cong-Ying Wen
    Peng Li
    Jian-Feng Yu
    Shi-Ming Tang
    Jing-Bin Zeng
    JournalofAnalysisandTesting, 2021, 5 (01) : 11 - 18