Study of Effective Length Factor of Frame-Core Wall Structure with Cross-Layer Columns

被引:0
作者
Mu, Zaigen [1 ]
Xu, Yue [1 ]
Yang, Yuqing [1 ]
Fan, Zhong [2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Resource Engn, Beijing 100083, Peoples R China
[2] China Architecture Design & Res Grp, Beijing 100044, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 12期
基金
中国国家自然科学基金;
关键词
frame-core wall structure; cross-layer column; effective length factor; mechanical behavior; FEM analysis; STABILITY; STORY;
D O I
10.3390/app13126875
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim of this study was to examine the effective length factor of frame-core wall structures with cross-layer columns, which are relevant for current high-rise building construction. Using the finite element method, improved inflection point method (D-value method), and GB50017-2017, the study investigated how the height and distribution of cross-layer columns affect the lateral stiffness ratio, natural vibration period, member internal force, maximum interlayer displacement angle, and effective length factor of the column in the frame-core wall structures. However, the force acting in the frame in the weak axis direction that is considered in GB50017-2017 does not reflect the actual mechanical behavior. Therefore, when determining the effective length factor of cross-layer columns, the interaction between the remaining frames' sub-structure and cross-layer columns is considered and the effective length factor is modified accordingly. A simplified model of a 140 m frame-core wall structure was established for analysis, and it was assumed that rigid links connect the frame and core wall hinged at both ends. The results show that increasing the height and number of cross-layer columns decreased the lateral stiffness ratio of the structure, and increased the maximum interlayer displacement angle and natural vibration period. Furthermore, the effective length factor of the structure decreased with an increase in height and the number of cross-layer columns. The modified effective length factor agrees well with the results obtained by the finite element method. These findings provide a useful reference for calculating the load-carrying capacity of cross-layer columns in engineering.
引用
收藏
页数:13
相关论文
共 25 条
[1]  
ABAQUS Inc, 2011, AN US MAN I V VERS 6
[2]  
[Anonymous], 2010, GB50011-2010
[3]  
[Anonymous], 2017, GB50017-2017
[4]  
[Anonymous], 2016, AISC 360 16
[5]   Large deflection stability of slender beam-columns with semirigid connections:: Elastica approach [J].
Aristizábal-Ochoa, JD .
JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (03) :274-282
[6]   Story stability of braced, partially braced, and unbraced frames: Classical approach [J].
AristizabalOchoa, JD .
JOURNAL OF STRUCTURAL ENGINEERING, 1997, 123 (06) :799-807
[7]  
Chen W.F., 1997, LRFD steel design using advanced analysis
[8]   Experimental and numerical investigations into the behavior of circular concrete-filled double steel tubular slender columns [J].
Ci, Junchang ;
Ahmed, Mizan ;
Liang, Qing Quan ;
Chen, Shicai ;
Chen, Wensu ;
Sennah, Khaled ;
Hamoda, Ahmed .
ENGINEERING STRUCTURES, 2022, 267
[9]  
de Construcao A.P., 2005, 3 EUR COMM STAND
[10]   The influence of inter-module connections on the effective length of columns in multi-story modular steel frames [J].
Farajian, M. ;
Sharafi, P. ;
Kildashti, K. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 177