On-load tap changer; Compatibility test; Solid insulating materials;
D O I
10.1109/CE/DP5414.2023.10410466
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The insulation system of On-load tap changer (OLTC) is composed of insulating oil and the solid insulating materials in OLTC. The compatibility of solid insulating materials in OLTC with mineral insulating oil is one of the most important factors to decide the long-term reliable operation of OLTC. However, the compatibility of OLTC insulating components with mineral insulating oil is seldom studied. In this work, the effect of insulating materials, such as Epoxy Phenolic Glass Cloth Laminates (EPGCL3248), Epoxy Glass Fiber (EGF), Reinforced Nylon (PA66), Polyformaldehyde (POM) on the electrical and physicochemical properties of insulating oil were analyzed. The solid insulating materials were immersed in 800 mL insulating oil separately, and aged at 90 degrees C, 100 degrees C, 110 degrees C, and 130 degrees C. The aging time is 20 h, 41 h, 82 h, and 164 h, respectively. After the thermal aging, the water content, breakdown voltage, dielectric loss and acidity of insulating oil samples were tested, and the compatibility between the insulating oil and the solid insulating materials was analyzed. Among the solid insulating materials used in OLTC, the Nylon PA66 exhibits poor compatibility with mineral oil. The research results provide useful advises for the selection, optimization and replacement of OLTC solid insulating materials.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Vibration Characteristic Comparison Between Vacuum Arcing On-load Tap-changer and Oil Blast On-load Tap-changer
    Wang F.
    Fan J.
    Zheng Y.
    He W.
    Qian Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (09): : 2834 - 2841
  • [2] Dynamic behaviour of a suspended bubble and its influence on the distribution of electric fields in insulating oil of an on-load tap-changer within power transformers
    Liu, Chenlei
    Zhao, Tong
    Sun, Ying
    Wang, Xiaolong
    Cao, Shi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 145
  • [3] Improved on-load tap changer scheme
    Fan, C.
    Power, A.
    Shuttleworth, R.
    Tian, X.
    1994, 2 : 633 - 636
  • [4] A new approach of tap changer maintenance incorporating nanoparticle insulating oil
    Sherif S. M. Ghoneim
    Sobhy S. Dessouky
    Ibrahim B. M. Taha
    Mohamed Shaaban
    Saad A. Mohamed Abdelwahab
    Electrical Engineering, 2021, 103 : 931 - 944
  • [5] A new approach of tap changer maintenance incorporating nanoparticle insulating oil
    Ghoneim, Sherif S. M.
    Dessouky, Sobhy S.
    Taha, Ibrahim B. M.
    Shaaban, Mohamed
    Abdelwahab, Saad A. Mohamed
    ELECTRICAL ENGINEERING, 2021, 103 (02) : 931 - 944
  • [6] Application vibroacoustic in the diagnosis of on-load tap changer
    Raclaw, Marcin
    Gielniak, Jaroslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (10): : 126 - 129
  • [7] Switching characteristic of quick mechanism for on-load tap-changer in oil environment
    Mao, Guoxin
    Wang, Ke
    Li, Geqi
    Zhang, Jinhua
    Hong, Jun
    Fang, Bin
    Zhuang, Jian
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2024, 58 (11): : 2309 - 2319
  • [8] Compatibility of Mineral Insulating Oil with Transformer Construction Materials
    Bernard, Natasa
    Cucek, Biljana
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2017,
  • [9] Research on the Switching Arc Loss of on-Load Tap Changer
    Song, Dongdong
    Ma, Jiwei
    Ma, Yuquan
    Lin, Hongju
    Liu, Shengtao
    IEEE ACCESS, 2019, 7 : 180793 - 180803
  • [10] On-load tap changer diagnosis with dynamic resistance measurements
    Jongen, Rogier
    Seitz, Paul P.
    Strehl, Thomas
    Smit, Johan
    Leich, Rory
    Gulski, Edward
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 485 - 488