共 50 条
The effect of ultrasonic shot peening on micro-arc oxidation results of Ti-6Al-4V alloy
被引:11
作者:
Li, Yongjian
[1
]
Liu, Xiaoting
[2
]
Wang, Fang
[3
]
Du, Chengchao
[1
]
Zhou, Wangfan
[1
]
Yu, Zhenglei
[4
]
Ren, Xudong
[1
]
机构:
[1] Jiangsu Univ, Sch Mech Engn, Zhenjiang 212013, Peoples R China
[2] Army Acad Armored Forces, Natl Key Lab Remfg, Beijing 100072, Peoples R China
[3] Zhenjiang Stomatol Hosp, Zhenjiang, Peoples R China
[4] Jilin Univ, Key Lab Engn Bion, Minist Educ, Changchun 130022, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Ultrasonic shot peening;
Micro-arc oxidation;
Ti-6Al-4;
V;
Microstructure;
FATIGUE LIFE;
ALUMINUM;
D O I:
10.1016/j.mtcomm.2023.107557
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
Micro-arc oxidation (MAO) is widely used in Ti-6Al-4V (TC4) alloy for surface modification and good biocompatibility in dental and orthopedic applications. However, it is a big challenge to produce thick MAO layers and nanoscale pores, both of which are crucial for biocompatibility. In this study, a new method called USMAO has been proposed, which involves performing USP as a pretreatment on the surface of TC4 before MAO. The results showed that USP could cause significant grain fragmentation and plastic deformation. After USMAO, composite architectures at the micron and nanoscale formed on the surfaces, and a thick MAO layer with a thickness of up to 30 mu m could be also obtained, which was very useful for TC4 to enhance biocompatibility.