Refractory diffuse coronary artery spasm post aortic valve replacement

被引:1
|
作者
Nagasawa, Ayako [1 ]
Okonogi, Shuichi [1 ]
Ohki, Satoshi [1 ]
Ohbayashi, Tamiyuki [1 ]
机构
[1] Isesaki City Hosp, Dept Cardiovasc Surg, 12-1 Tunatorihoncho, Isesaki, Gunma, Japan
来源
INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY | 2023年 / 36卷 / 01期
关键词
Coronary spasm; Perioperative myocardial infarction; Aortic valve replacement;
D O I
10.1093/icvts/ivac288
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Postoperative coronary artery spasm occurs rarely after valve replacement surgery. We report the case of a 64-year-old man with normal coronary arteries who underwent aortic valve replacement. Nineteen hours postoperatively, his blood pressure plummeted with an elevated ST-segment. Coronary angiography demonstrated a 3-vessel diffuse coronary artery spasm, and direct intracoronary infusion therapy was performed with isosorbide nitrate, nicorandil and sodium nitroprusside hydrate within 1 h of onset. Nonetheless, there was no improvement, and the patient was resistant to treatment. The patient died due to prolonged low cardiac function and pneumonia complications. Prompt intracoronary vasodilator infusion is considered effective. However, this case was refractory to multi-drug intracoronary infusion therapy and was not salvageable. Postoperative coronary artery spasm (CAS) is an infrequent life-threatening event after cardiac surgery that can occur without an underlying coronary disease.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Aortic valve replacement in a single coronary artery arising from the right Valsalva sinus
    Gallo, Michele
    Lika, Alban
    Gerosa, Gino
    Colli, Andrea
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (05) : E141 - E141
  • [22] The impact of coronary artery disease on the quality of life of patients undergoing aortic valve replacement
    Markou, Athanasios L. P.
    de Jager, Marieke J.
    Noyez, Luc
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 13 (02) : 128 - 132
  • [23] REGRESSION OF CORONARY-ARTERY DIMENSIONS AFTER SUCCESSFUL AORTIC-VALVE REPLACEMENT
    VILLARI, B
    HESS, OM
    MEIER, C
    PUCILLO, A
    GAGLIONE, A
    TURINA, M
    KRAYENBUEHL, HP
    CIRCULATION, 1992, 85 (03) : 972 - 978
  • [24] MEDICAL-TREATMENT OF REFRACTORY CORONARY-ARTERY SPASM
    LEFROY, DC
    CRAKE, T
    HAIDER, AW
    MASERI, A
    CORONARY ARTERY DISEASE, 1992, 3 (08) : 745 - 752
  • [25] Coronary Artery Bypass Grafting for Refractory Ventricular fibrillation after the Release of the Aortic Cross-Clamp in Patients Undergoing Aortic Valve Replacement: A Case Report
    Yu, Xiao-Jie
    Ma, Da-Shi
    Qiu, Mu-Shui
    HEART SURGERY FORUM, 2024, 27 (02): : E85 - E88
  • [26] Effect of Aortic Valve Replacement on the Carotid Artery Distensibility in Patients with Aortic Valve Diseases
    Yukio Umeda
    Yasunari Yokota
    Yoshio Mori
    Yoko Kawamura
    Hiroshi Takiya
    Journal of Cardiothoracic Surgery, 10 (Suppl 1)
  • [27] Severe diffuse coronary artery spasm in the early phase of cardiogenic shock
    Lilli, Alessio
    Vecchio, Sabine
    Vittori, Guido
    Consoli, Lorenzo
    Chechi, Tania
    Margheri, Massimo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 134 (03) : E103 - E104
  • [28] Aortic Valve Replacement with and without Coronary Artery Bypass Graft Surgery in Octogenarians: Is It Safe and Feasible?
    Abel, N. J.
    Rogal, G. J.
    Burns, P.
    Saunders, C. R.
    Chamberlain, R. S.
    CARDIOLOGY, 2013, 124 (03) : 163 - 173
  • [29] Percutaneous aspiration of calcium debris resulting in coronary artery occlusion after aortic valve replacement
    Simek, Martin
    Sluka, Martin
    Gwozdziewicz, Marek
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (04) : 793 - 793
  • [30] Mobilization of an anomalous retroaortic coronary artery to prevent myocardial ischemia after aortic valve replacement
    Maximo, Jose
    Pinho, Paulo
    Casanova, Jorge
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (09) : 3436 - 3438