The Porosity Design and Deformation Behavior Analysis of Additively Manufactured Bone Scaffolds through Finite Element Modelling and Mechanical Property Investigations

被引:2
|
作者
Rasheed, Shummaila [1 ]
Lughmani, Waqas Akbar [2 ]
Khan, Muhammad Mahabat [1 ]
Brabazon, Dermot [3 ]
Obeidi, Muhannad Ahmed [3 ]
Ahad, Inam Ul [3 ]
机构
[1] Capital Univ Sci & Technol, Dept Mech Engn, Islamabad 44000, Pakistan
[2] Ghulam Ishaq Khan Inst Engn Sci & Technol, Fac Mech Engn, Topi 23460, Pakistan
[3] Dublin City Univ, SFI Res Ctr Adv Mfg, Sch Mech & Mfg Engn, I Form, Dublin, Ireland
基金
爱尔兰科学基金会; 英国工程与自然科学研究理事会;
关键词
polymeric bone scaffolds; 3D printing; mechanical response; finite element method; deformation pattern; crushable foam plasticity model; ARCHITECTURE; STRENGTH; FAILURE;
D O I
10.3390/jfb14100496
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Additively manufactured synthetic bone scaffolds have emerged as promising candidates for the replacement and regeneration of damaged and diseased bones. By employing optimal pore architecture, including pore morphology, sizes, and porosities, 3D-printed scaffolds can closely mimic the mechanical properties of natural bone and withstand external loads. This study aims to investigate the deformation pattern exhibited by polymeric bone scaffolds fabricated using the PolyJet (PJ) 3D printing technique. Cubic and hexagonal closed-packed uniform scaffolds with porosities of 30%, 50%, and 70% are utilized in finite element (FE) models. The crushable foam plasticity model is employed to analyze the scaffolds' mechanical response under quasi-static compression. Experimental validation of the FE results demonstrates a favorable agreement, with an average percentage error of 12.27% +/- 7.1%. Moreover, the yield strength and elastic modulus of the scaffolds are evaluated and compared, revealing notable differences between cubic and hexagonal closed-packed designs. The 30%, 50%, and 70% porous cubic pore-shaped bone scaffolds exhibit significantly higher yield strengths of 46.89%, 58.29%, and 66.09%, respectively, compared to the hexagonal closed-packed bone scaffolds at percentage strains of 5%, 6%, and 7%. Similarly, the elastic modulus of the 30%, 50%, and 70% porous cubic pore-shaped bone scaffolds is 42.68%, 59.70%, and 58.18% higher, respectively, than the hexagonal closed-packed bone scaffolds at the same percentage strain levels. Furthermore, it is observed in comparison with our previous study the mu SLA-printed bone scaffolds demonstrate 1.5 times higher elastic moduli and yield strengths compared to the PJ-printed bone scaffolds.
引用
收藏
页数:19
相关论文
共 14 条
  • [1] Prediction of mechanical behavior of 3D bioprinted tissue-engineered scaffolds using finite element method (FEM) analysis
    Soufivand, Anahita Ahmadi
    Abolfathi, Nabiollah
    Hashemi, Seyyed Ataollah
    Lee, Sang Jin
    ADDITIVE MANUFACTURING, 2020, 33 (33)
  • [2] Assessment of fiber reinforcement strategies for additively manufactured thermoplastic composites using mechanical testing and finite element analysis
    Shih, Yu-Chao
    Ning, Haibin
    Sen, Subhayu
    Mohamed, Mahmoud
    Yan, Yongzhe
    Pillay, Selvum
    PROGRESS IN ADDITIVE MANUFACTURING, 2024, 9 (06) : 2175 - 2188
  • [3] Investigation of mechanical behavior of CPC/bone specimens by finite element analysis
    Yu, Tao
    Liu, Xuan
    Ye, Jiandong
    Zhang, Ming
    CERAMICS INTERNATIONAL, 2014, 40 (02) : 2933 - 2942
  • [4] Finite element analysis of mechanical behavior, permeability of irregular porous scaffolds and lattice-based porous scaffolds
    Du, Yue
    Liang, Huixin
    Xie, Deqiao
    Mao, Ning
    Zhao, Jianfeng
    Tian, Zongjun
    Wang, Changjiang
    Shen, Lida
    MATERIALS RESEARCH EXPRESS, 2019, 6 (10)
  • [5] Characterizing the biaxial compressive deformation behavior of epoxy polymer through cruciform experiment and finite element analysis
    Park, Hyungbum
    Han, Jang-Woo
    Na, Wonjin
    Yu, Jaesang
    COMPOSITE STRUCTURES, 2023, 305
  • [6] Design Data and Finite Element Analysis of 3D Printed Poly(ε-Caprolactone)-Based Lattice Scaffolds: Influence of Type of Unit Cell, Porosity, and Nozzle Diameter on the Mechanical Behavior
    Sala, Riccardo
    Regondi, Stefano
    Pugliese, Raffaele
    ENG, 2022, 3 (01): : 9 - 23
  • [7] Structural behavior and mechanical fatigue of plate and shell heat exchangers through finite element analysis
    de Santiago, Rodrigo Silveira
    Possamai, Talita Sauter
    Donati, Damylle Cristina Xavier
    Martins, Giovani Silveira de Magalhaes
    Oba, Renato
    Tascheck, Bruna Larissa
    de Paiva, Kleber Vieira
    Oliveira, Jorge Luiz Goes
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2024, 210
  • [8] Influence of conservative endodontic access and the osteoporotic bone on the restoration material adhesive behavior through finite element analysis
    Goncalves Franco, Aline Batista
    Franco, Amanda Goncalves
    Pinheiro de Carvalho, Geraldo Alberto
    Ramos, Elimario Venturin
    Faria Amorim, Jose Claudio
    de Martim, Alexandre Sigrist
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2020, 31 (04)
  • [9] Identifying structure-property relationships of micro-architectured porous scaffolds through 3D printing and finite element analysis
    Yang, Zhangke
    Niksiar, Pooya
    Meng, Zhaoxu
    COMPUTATIONAL MATERIALS SCIENCE, 2022, 202
  • [10] Three-dimensional real structure-based finite element analysis of mechanical behavior for porous titanium manufactured by a space holder method
    Lee, Dong Jun
    Jung, Jai Myun
    Latypov, Marat I.
    Lee, Byounggab
    Jeong, Jiwon
    Oh, Sang Ho
    Lee, Chong Soo
    Kim, Hyoung Seop
    COMPUTATIONAL MATERIALS SCIENCE, 2015, 100 : 2 - 7