A new method for measuring thermal resistance of building walls and analyses of influencing factors

被引:4
|
作者
Chen, Lufang [1 ]
Zhang, Yun [2 ]
Zhou, Xin [1 ]
Shi, Xing [3 ]
Yang, Liu [4 ]
Jin, Xing [1 ,5 ]
机构
[1] Southeast Univ, Sch Architecture, 2 Sipailou, Nanjing 210096, Peoples R China
[2] Nanjing Yangtze River Urban Architectural Design C, 19, Nanjing 210022, Peoples R China
[3] Tongji Univ, Coll Architecture & Urban Planning, Shanghai 200092, Peoples R China
[4] Southeast Univ, Sch Energy & Environm, 2 Sipailou, Nanjing 210096, Peoples R China
[5] Minist Educ, Engn Res Ctr BEEE, Wuhan, Peoples R China
关键词
Thermal resistance; Building wall; Analytical solution; Measurement method; Influencing factors; IN-SITU MEASUREMENT; PCM; THERMOGRAPHY; COMPONENTS; DIAGNOSIS;
D O I
10.1016/j.conbuildmat.2023.131438
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thermal resistance of the building wall is one of the most important parameters of thermal performance, it will impact the building energy consumption and indoor thermal comfort directly and greatly. The present methods for thermal resistance measurement of building walls are mainly derived from the heat flow meter method and the hot box method, which require a rigorous measurement environment and tedious measurement steps. In this paper, a new method to measure the thermal resistance of the building walls based on the analytical solution was proposed. Firstly, a board was placed on the interior surface of a wall, and an analytical solution of the heat transfer process in the building wall along with the board was obtained. Then the temperature of the interface between the wall and the board was measured. Finally, the thermal resistance of the wall could be calculated based on the analytical solution and the measured temperature values. The new method was also verified in this research. It was found that no matter the single-layer or the multi-layer walls, the relative errors were all less than 10%. When the thermal resistance of the building wall is low, a board with low thermal conductivity such as fiberboard could be used. When the thermal resistance of the building wall is high, the flat glass is a good choice. The temperature values of the interface at the moments of 70 h and 75 h are suitable to calculate the thermal resistance of the building wall.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Measuring the thermal resistance of typical multi-layer building walls using the accelerated measurement method
    Zubkov, Daniil
    Chusov, Alexander
    Molodtsov, Dmitry
    INTERNATIONAL SCIENTIFIC CONFERENCE WEEK OF SCIENCE IN SPBPU - CIVIL ENGINEERING (SPBWOSCE-2015), 2016, 53
  • [2] FACTORS INFLUENCING AND A METHOD FOR MEASURING THE THERMAL-STABILITY OF FISHMEAL
    ROMOSER, GL
    GROGAN, F
    ROOS, MA
    SHERMER, W
    BAKER, JW
    POULTRY SCIENCE, 1979, 58 (04) : 1100 - 1100
  • [3] A NEW METHOD FOR MEASURING SOMATIC MUTATION INVIVO AND FACTORS INFLUENCING IT
    ADAMS, DD
    PARKINSON, RT
    KNIGHT, JG
    AUSTRALIAN PAEDIATRIC JOURNAL, 1986, 22 (04): : 343 - 343
  • [4] Parametric study of the method for determining the thermal diffusivity of building walls by measuring the temperature profile
    Owczarek, Mariusz
    ENERGY AND BUILDINGS, 2019, 203
  • [5] ANALYSES OF THE FACTORS INFLUENCING SANDSTONE THERMAL CONDUCTIVITY
    Sun, Qiang
    Chen, Shen-en
    Gao, Qiao
    Zhang, Weiqiang
    Geng, Jishi
    Zhang, Yuliang
    ACTA GEODYNAMICA ET GEOMATERIALIA, 2017, 14 (02): : 173 - 180
  • [7] Analysis of factors influencing actual absorption of solar energy by building walls
    Li, He
    Jia, Hongwei
    Zhong, Ke
    Zhai, Zhiqiang
    ENERGY, 2021, 215
  • [8] In situ measuring and evaluating the thermal resistance of building construction
    Peng, Changhai
    Wu, Zhishen
    ENERGY AND BUILDINGS, 2008, 40 (11) : 2076 - 2082
  • [9] Factors influencing thermal resistance of a down sleeping bag
    An, Yuying
    Xu, Guangbiao
    Shen, Hua
    INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY, 2021, 33 (06) : 966 - 979
  • [10] A NEW METHOD OF MEASURING DEFORMATIONS IN DIAPHRAGM WALLS AND PILES
    KOVARI, K
    AMSTAD, C
    GEOTECHNIQUE, 1982, 32 (04): : 402 - 406