Chromium-Benzenedicarboxylates Metal Organic Framework for Supersensitive and Selective Electrochemical Sensor of Toxic Cd2+, Pb2+, and Hg2+Metal Ions: Study of their Interactive Mechanism

被引:12
作者
Deore, Kamlesh B. [1 ]
Patil, Shubham S. [1 ]
Narwade, Vijaykiran N. [1 ]
Takte, Mahesh A. [1 ]
Khune, Abhaysinh S. [1 ]
Mohammed, Hamed Y. [1 ]
Farea, Maamon A. [1 ]
Sayyad, Pasha W. [1 ]
Tsai, Meng-Lin [2 ]
Shirsat, Mahendra D. [1 ,3 ]
机构
[1] Dr Babasaheb Ambedkar Marathwada Univ, RUSA Ctr Adv Sensor Technol, Dept Phys, Aurangabad 431004, MS, India
[2] Natl Taiwan Univ Sci & Technol, Dept Mat Sci & Engn, Taipei 10607, Taiwan
[3] Comenius Univ, Fac Math Phys & Informat, Dept Nucl Phys & Biophys, Bratislava, Slovakia
关键词
GRAPHENE OXIDE NANOCOMPOSITE; HEAVY-METALS; MIL-101(CR); PERFORMANCE; WATER; ADSORPTION; NANOPARTICLES; VOLTAMMETRY; REMOVAL; IMPACT;
D O I
10.1149/1945-7111/acc9df
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Voltammetric determination of toxic Cd2+, Pb2+, and Hg2+ metal ions using Cr-BDC/GCE (chromium-benzenedicarboxylates/ Glassy Carbon Electrode) electrochemical sensor has been investigated. Cr-BDC (chromium-benzenedicarboxylate) metal-organic framework was synthesized by using the facile hydrothermal technique and its efficacy investigated using P-XRD, FTIR, RAMAN, AFM, FE-SEM, and BET, while the electrochemical performance was investigated by CV and EIS technique. The determination capability of Cr-BDC/GCE as an electrochemical sensor has been investigated by DPASV technique. Effective Voltammetric parameters such as pH of buffer solution, pre-accumulation potential, and pre-accumulation time have been optimized to enhance the sensitivity, selectivity, LOD, repeatability, reproducibility, and stability of the sensor. The proposed CrBDC/GCE electrochemical sensor exhibits a sensitivity of 16.55, 3.45, and 3.33 mu A M-1 and LOD of 0.186, 0.116, and 0.124 nM for Cd2+, Pb2+ and Hg2+ ions, respectively. Moreover, the sensor exhibited good selectivity, reproducibility, repeatability and stability. The sensor also exhibited good recovery and low RSD values for actual tap water samples. Interaction mechanism of Heavy Metal Ions with the Cr-BDC/GCE evidenced by CV and FTIR confirms the surface adsorption-controlled reaction. These findings suggest that the Cr-BDC/GCE platform is well-suited to serve as a next-generation electrochemical sensor for detecting alcohol, ketone, hydrocarbons, medicines, etc.
引用
收藏
页数:12
相关论文
共 49 条
  • [1] Bioaccumulation of non-essential hazardous heavy metals and metalloids in freshwater fish. Risk to human health
    Ali, Hazrat
    Khan, Ezzat
    [J]. ENVIRONMENTAL CHEMISTRY LETTERS, 2018, 16 (03) : 903 - 917
  • [2] Heavy metals in human teeth dentine: A bio-indicator of metals exposure and environmental pollution
    Asaduzzaman, Khandoker
    Khandaker, Mayeen Uddin
    Baharudin, Nurul Aticiah Binti
    Amin, Yusoff Bin Mohd
    Farook, Mohideen Salihu
    Bradley, D. A.
    Mahrnoud, Okba
    [J]. CHEMOSPHERE, 2017, 176 : 221 - 230
  • [3] A New Strategy for Heavy Metal Polluted Environments: A Review of Microbial Biosorbents
    Ayangbenro, Ayansina Segun
    Babalola, Olubukola Oluranti
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (01)
  • [4] Ag@MOF-199 metal organic framework for selective detection of nickel ions in aqueous media
    Bodkhe, Gajanan A.
    Khandagale, Dhanashri D.
    More, Mayuri S.
    Deshmukh, Megha A.
    Ingle, Nikesh N.
    Sayyad, Pasha W.
    Mahadik, Manasi M.
    Shirsat, Sumedh M.
    Al-Buriahi, M. S.
    Tsai, Meng-Lin
    Kim, Myunghee
    Shirsat, Mahendra D.
    [J]. CERAMICS INTERNATIONAL, 2023, 49 (04) : 6772 - 6779
  • [5] cdc, 2007, ATSDR
  • [6] Heavy metals in drinking water: Occurrences, implications, and future needs in developing countries
    Chowdhury, Shakhawat
    Mazumder, M. A. Jafar
    Al-Attas, Omar
    Husain, Tahir
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 569 : 476 - 488
  • [7] Enhanced stripping voltammetric response of Hg2+, Cu2+, Pb2+and Cd2+ by ZIF-8 and its electrochemical analytical application
    Chu, Yaru
    Gao, Feng
    Gao, Fei
    Wang, Qingxiang
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 835 : 293 - 300
  • [8] Elaboration and properties of hierarchically structured optical thin films of MIL-101(Cr)
    Demessence, Aude
    Horcajada, Patricia
    Serre, Christian
    Boissiere, Cedric
    Grosso, David
    Sanchez, Clement
    Ferey, Gerard
    [J]. CHEMICAL COMMUNICATIONS, 2009, (46) : 7149 - 7151
  • [9] EDTA-modified PANI/SWNTs nanocomposite for differential pulse voltammetry based determination of Cu(II) ions
    Deshmukh, Megha A.
    Patil, Harshada K.
    Bodkhe, Gajanan A.
    Yasuzawa, Mikito
    Koinkar, Pankaj
    Ramanaviciene, Almira
    Shirsat, Mahendra D.
    Ramanavicius, Arunas
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 : 331 - 338
  • [10] EDTA_PANI/SWCNTs nanocomposite modified electrode for electrochemical determination of copper (II), lead (II) and mercury (II) ions
    Deshmukh, Megha A.
    Celiesiute, Raimonda
    Ramanaviciene, Almira
    Shirsat, Mahendra D.
    Ramanavicius, Arunas
    [J]. ELECTROCHIMICA ACTA, 2018, 259 : 930 - 938