Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Clinical and Radiographic Outcomes in Total Knee Arthroplasty at 10-Year Follow-up

被引:1
作者
Remily, Ethan A. [1 ]
Wilkie, Wayne A. [1 ]
Mohamed, Nequesha S. [1 ]
Smith, Langan S. [2 ]
Malkani, Arthur L. [2 ]
Jaggard, Charles E. [3 ]
Kolisek, Frank R. [3 ]
Monesmith, Eric A. [3 ]
Nace, James [1 ]
Delanois, Ronald E. [1 ,4 ]
机构
[1] Sinai Hosp Baltimore, Rubin Inst Adv Orthoped, Ctr Joint Preservat & Replacement, Baltimore, MD USA
[2] Univ Louisville, Dept Orthopaed Surg, Adult Reconstruct Program, Louisville, KY USA
[3] OrthoIndy, Indianapolis, IN USA
[4] Sinai Hosp Baltimore, Rubin Inst Adv Orthoped, Ctr Joint Preservat & Replacement, 2401 Belvedere Ave, Baltimore, MD 21215 USA
关键词
PERIPROSTHETIC OSTEOLYSIS; WEAR;
D O I
10.3928/01477447-20221129-02
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Highly cross-linked polyethylene (HXLPE) has become the preferred bear-ing surface in total hip arthroplasty. However, its acceptance in total knee arthroplasty (TKA) has not been as robust because of concerns pertain-ing to wear and its impact on implant failure. Therefore, this multicenter study was purposed to evaluate the 10-year (1) radiographic outcomes; (2) complications; and (3) implant survivorship in patients with TKA receiv-ing a sequentially irradiated and annealed HXLPE. A retrospective, multi-center study was performed on 139 patients (171 TKAs) who underwent primary TKA with HXLPE and possessed a minimum of 10-year follow-up. Radiographs were analyzed for radiolucencies along the implant-fixation interface using the Modern Knee Society Radiographic Evaluation Sys-tem. Kaplan-Meier analysis determined implant survivorship when the end points were revision for polyethylene wear and polyethylene revision for any reason. Sixteen TKAs (9.9%) demonstrated periprosthetic linear radio-lucencies. Seventeen TKAs (9.9%) required additional surgeries, 9 (5.3%) of which were revisions, with 1 (0.6%) TKA requiring revision because of polyethylene wear. Other causes of revision included instability (1.8%), in-fection (1.6%), and arthrofibrosis (1.6%). The mean time to revision was 5.9 years (range, 0.1-11.1 years). Survivorship pertaining to polyethylene revision for wear was 99.4%, whereas all-cause polyethylene revision was 94.7%. This study in patients undergoing primary TKA using a second -gen-eration HXLPE demonstrated excellent results with respect to polyethylene wear characteristics and strength with a 99.4% survivorship at 10 years.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 24 条
[1]   Is Cross-Linked Polyethylene an Improvement Over Conventional Ultra-High Molecular Weight Polyethylene in Total Knee Arthroplasty? [J].
Boyer, Bertrand ;
Bordini, Barbara ;
Caputo, Dalila ;
Neri, Thomas ;
Stea, Susanna ;
Toni, Aldo .
JOURNAL OF ARTHROPLASTY, 2018, 33 (03) :908-914
[2]   Uncemented vs Cemented Cruciate Retaining Total Knee Arthroplasty in Patients With Body Mass Index Greater Than 30 [J].
Boyle, K. Keely ;
Nodzo, Scott R. ;
Ferraro, Joseph T. ;
Augenblick, David J. ;
Pavlesen, Sonja ;
Phillips, Matthew J. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (04) :1082-1088
[3]   The basis for a second-generation highly cross-linked UHMWPE [J].
Dumbleton, John H. ;
D'Antonio, James A. ;
Manley, Michael T. ;
Capello, William N. ;
Wang, Aiguo .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :265-271
[4]   Wear and Loosening in Total Knee Arthroplasty: A Quick Review [J].
Fraser, James F. ;
Werner, Steven ;
Jacofsky, David J. .
JOURNAL OF KNEE SURGERY, 2015, 28 (02) :139-144
[5]   Osteolysis around total knee arthroplasty: A review of pathogenetic mechanisms [J].
Gallo, J. ;
Goodman, S. B. ;
Konttinen, Y. T. ;
Wimmer, M. A. ;
Holinka, M. .
ACTA BIOMATERIALIA, 2013, 9 (09) :8046-8058
[6]   WOMAC, EQ-5D and Knee Society Score Thresholds for Treatment Success After Total Knee Arthroplasty [J].
Giesinger, Johannes M. ;
Hamilton, David F. ;
Jost, Bernhard ;
Behrend, Henrik ;
Giesinger, Karlmeinrad .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2154-2158
[7]  
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13
[8]   Construct validity of the SF-12 in three different samples [J].
Jakobsson, Ulf ;
Westergren, Albert ;
Lindskov, Susanne ;
Hagell, Peter .
JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2012, 18 (03) :560-566
[9]  
Konopka Joseph F, 2018, JB JS Open Access, V3, pe0007, DOI 10.2106/JBJS.OA.18.00007
[10]   Oxidation of Second Generation Sequentially Irradiated and Annealed Highly Cross-Linked X3™ Polyethylene Tibial Bearings [J].
Kop, Alan M. ;
Pabbruwe, Moreica B. ;
Keogh, Catherine ;
Swarts, Eric .
JOURNAL OF ARTHROPLASTY, 2015, 30 (10) :1842-1846