Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study

被引:1
作者
Ma, Feifei [1 ,2 ]
Liu, Mingyue [1 ,2 ]
Liu, Xiaoqiang [3 ,4 ]
Wei, Tai [1 ,2 ]
Liu, Lilan [1 ,2 ]
Sun, Feng [1 ,2 ]
机构
[1] Peking Univ Sch, Clin Div 1, Beijing 100034, Peoples R China
[2] Hosp Stomatol, Beijing 100034, Peoples R China
[3] Peking Univ Sch, Dept Prosthodont, Beijing 100081, Peoples R China
[4] Hosp Stomatol, Beijing 100081, Peoples R China
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 02期
基金
中国国家自然科学基金;
关键词
dental implants; dynamic navigation; postoperative implant position evaluation; computer-guided implantology; INTRAORAL SCAN; ACCURACY; PLACEMENT;
D O I
10.3390/jpm13020362
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: To propose a novel, radiation-free method for postoperative three-dimensional (3D) position analysis of dental implants based on the dynamic navigation system (DNS) and evaluate its accuracy in vitro. Methods: A total of 60 implants were digitally planned and then placed in the standardized plastic models with a single-tooth gap and a free-end gap under the guidance of the DNS. Postoperative 3D positions of the inserted implants were evaluated using specially designed navigation-based software, and its datasets were superimposed onto those of cone beam computed tomography (CBCT) for accuracy analyses. Deviations at the coronal, apical, and angular levels were measured and statistically analyzed. Results: The mean 3D deviation was 0.88 +/- 0.37 mm at the entry point and 1.02 +/- 0.35 mm at the apex point. The mean angular deviation was 1.83 +/- 0.79 degrees. No significant differences were noted in the deviations between implants placed in the single-tooth gap and the free-end situation (p > 0.05) or between different tooth positions at distal extensions (p > 0.05). Conclusions: This non-radiographic method provides facile, efficient, and reliable postoperative implant position evaluation and may be a potential substitute for CBCT, particularly for implants placed under the guidance of dynamic navigation.
引用
收藏
页数:12
相关论文
共 29 条
  • [1] A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
    Al-Ekrish, A. A.
    Ekram, M.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) : 67 - 75
  • [2] Accuracy of dental implant placement via dynamic navigation or the freehand method: A split-mouth randomized controlled clinical trial
    Aydemir, Ceyda Aktolun
    Arisan, Volkan
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (03) : 255 - 263
  • [3] Implant Placement Accuracy Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Lank, Kathryn
    Ryan, James
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 92 - 99
  • [4] 10-Year Survival and Success Rates of 511 Titanium Implants with a Sandblasted and Acid-Etched Surface: A Retrospective Study in 303 Partially Edentulous Patients
    Buser, Daniel
    Janner, Simone F. M.
    Wittneben, Julia-Gabriela
    Braegger, Urs
    Ramseier, Christoph A.
    Salvi, Giovanni E.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) : 839 - 851
  • [5] Clinical applications and effectiveness of guided implant surgery: a critical review based on randomized controlled trials
    Colombo, Marco
    Mangano, Carlo
    Mijiritsky, Eitan
    Krebs, Mischa
    Hauschild, Uli
    Fortin, Thomas
    [J]. BMC ORAL HEALTH, 2017, 17
  • [6] Current state of the art of computer-guided implant surgery
    D'haese, Jan
    Ackhurst, Johan
    Wismeijer, Daniel
    De Bruyn, Hugo
    Tahmaseb, Ali
    [J]. PERIODONTOLOGY 2000, 2017, 73 (01) : 121 - 133
  • [7] Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial
    Edelmann, Cornelia
    Wetzel, Martin
    Knipper, Anne
    Luthardt, Ralph G.
    Schnutenhaus, Sigmar
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [8] Accuracy of computer-guided implant placement in anterior regions
    Fang, Yiqin
    An, Xueyin
    Jeong, Seung-Mi
    Choi, Byung-Ho
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (05) : 836 - 842
  • [9] Validation of an Intra-Oral Scan Method Versus Cone Beam Computed Tomography Superimposition to Assess the Accuracy between Planned and Achieved Dental Implants: A Randomized In Vitro Study
    Franchina, Alessio
    Stefanelli, Luigi V.
    Maltese, Fabio
    Mandelaris, George A.
    Vantaggiato, Alessandro
    Pagliarulo, Michele
    Pranno, Nicola
    Brauner, Edoardo
    De Angelis, Francesca
    Di Carlo, Stefano
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (24) : 1 - 21
  • [10] Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis
    Jorba-Garcia, Adria
    Gonzalez-Barnadas, Albert
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (05) : 2479 - 2494