Quantification of intra-fraction motion in breast radiotherapy using cine EPID images

被引:0
|
作者
Fouladinezhad, Behnaz [1 ]
Momennezhad, Mehdi [1 ,2 ]
Farjami, Parisa [3 ]
Naseri, Shahrokh [1 ]
机构
[1] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[2] Mashhad Univ Med Sci, Nucl Med Res Ctr, Mashhad, Iran
[3] Islamic Azad Univ, Dept Biol, Mashhad, Iran
关键词
Automated motion estimation algorithm; breast cancer; conformal radiation therapy; EPID; IRRADIATION; FREQUENCY; ALGORITHM;
D O I
10.1017/S1460396924000049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of this study was to develop a method for accurately measuring the intra-fraction motion in cine electronic portal imaging device (EPID) images of tangential breast irradiation. Patients and methods: The cine EPID images were acquired for 18 breast cancer patients during medial tangential breast radiotherapy. The skin surface and the chest wall were segmented separately in each EPID image using an automated MATLAB algorithm to obtain the magnitude of intra-fraction motion. Results: The patients had an average age of 55 years (range 43-69 years), with the highest observed displacement at 3<middle dot>50 mm. The mean intra-fraction motion due to respiration for the skin surface and chest wall was 1<middle dot>04 +/- 0<middle dot>24 mm and 1<middle dot>10 +/- 0<middle dot>27 mm, respectively. The amount of intra-fraction motion showed no significant association with either the patient's age or the side of the breast receiving the treatment. Conclusion: In this study, by utilising cine EPID technology and the automated MATLAB algorithm, the intra-fraction motion during breast radiotherapy treatment was accurately measured and analysed. Results indicate minimal skin surface and chest wall motion (approximately 1 mm), confirming negligible intra-fraction motions during conformal radiotherapy in breast cancer patients.
引用
收藏
页数:5
相关论文
共 33 条
  • [31] Three-dimensional intrafractional motion of breast during tangential breast irradiation monitored with high-sampling frequency using a real-time tumor-tracking radiotherapy system
    Kinoshita, Rumiko
    Shimizu, Shinichi
    Taguchi, Hiroshi
    Katoh, Norio
    Fujino, Masaharu
    Onimaru, Rikiya
    Aoyama, Hidefumi
    Katoh, Fumi
    Omatsu, Tokuhiko
    Ishikawa, Masayori
    Shirato, Hiroki
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03): : 931 - 934
  • [32] Analysis of Motion Detection of Breast Tumor Based on Tissue Elasticity From B Mode Ultrasound Images Using Gradient Method Optical Flow Algorithm
    Shuib, Farrah Masyitah Mohd
    Othman, Marinah
    Abdulrahim, Khairi
    Zulkifli, Zulistiana
    2013 FIRST INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE, MODELLING AND SIMULATION (AIMS 2013), 2013, : 278 - 283
  • [33] Comparing the robustness of different skin flash approaches using wide tangents, manual flash VMAT, and simulated organ motion robust optimization VMAT in breast and nodal radiotherapy
    Gleeson, Ian
    MEDICAL DOSIMETRY, 2022, 47 (03) : 264 - 272