Quantification of intra-fraction motion in breast radiotherapy using cine EPID images

被引:0
|
作者
Fouladinezhad, Behnaz [1 ]
Momennezhad, Mehdi [1 ,2 ]
Farjami, Parisa [3 ]
Naseri, Shahrokh [1 ]
机构
[1] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[2] Mashhad Univ Med Sci, Nucl Med Res Ctr, Mashhad, Iran
[3] Islamic Azad Univ, Dept Biol, Mashhad, Iran
关键词
Automated motion estimation algorithm; breast cancer; conformal radiation therapy; EPID; IRRADIATION; FREQUENCY; ALGORITHM;
D O I
10.1017/S1460396924000049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of this study was to develop a method for accurately measuring the intra-fraction motion in cine electronic portal imaging device (EPID) images of tangential breast irradiation. Patients and methods: The cine EPID images were acquired for 18 breast cancer patients during medial tangential breast radiotherapy. The skin surface and the chest wall were segmented separately in each EPID image using an automated MATLAB algorithm to obtain the magnitude of intra-fraction motion. Results: The patients had an average age of 55 years (range 43-69 years), with the highest observed displacement at 3<middle dot>50 mm. The mean intra-fraction motion due to respiration for the skin surface and chest wall was 1<middle dot>04 +/- 0<middle dot>24 mm and 1<middle dot>10 +/- 0<middle dot>27 mm, respectively. The amount of intra-fraction motion showed no significant association with either the patient's age or the side of the breast receiving the treatment. Conclusion: In this study, by utilising cine EPID technology and the automated MATLAB algorithm, the intra-fraction motion during breast radiotherapy treatment was accurately measured and analysed. Results indicate minimal skin surface and chest wall motion (approximately 1 mm), confirming negligible intra-fraction motions during conformal radiotherapy in breast cancer patients.
引用
收藏
页数:5
相关论文
共 33 条
  • [1] Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging
    van Heijst, Tristan C. F.
    Philippens, Marielle E. P.
    Charaghvandi, Ramona K.
    den Hartogh, Mariska D.
    Lagendijk, Jan J. W.
    van den Bongard, H. J. G. Desiree
    van Asselen, Bram
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1352 - 1370
  • [2] Real-time intra-fraction motion management in breast cancer radiotherapy: analysis of 2028 treatment sessions
    Reitz, D.
    Carl, G.
    Schoenecker, S.
    Pazos, M.
    Freislederer, P.
    Niyazi, M.
    Ganswindt, U.
    Alongi, F.
    Reiner, M.
    Belka, C.
    Corradini, S.
    RADIATION ONCOLOGY, 2018, 13
  • [3] Evaluation of intra- and inter-fraction motion in breast radiotherapy using electronic portal cine imaging
    Kron, T
    Lee, C
    Perera, F
    Yu, E
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (05) : 443 - 449
  • [4] Intra-fraction respiratory motion and baseline drift during breast Helical Tomotherapy
    Ricotti, Rosalinda
    Ciardo, Delia
    Fattori, Giovanni
    Leonardi, Maria Cristina
    Morra, Anna
    Dicuonzo, Samantha
    Rojas, Damaris
    Pansini, Floriana
    Cambria, Raffaella
    Cattani, Federica
    Gianoli, Chiara
    Spinelli, Chiara
    Riboldi, Marco
    Baroni, Guido
    Orecchia, Roberto
    Jereczek-Fossa, Barbara Alicja
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 (01) : 79 - 86
  • [5] Preoperative single fraction breast radiotherapy: Intra-fraction geometric uncertainties and dosimetric implications
    Masi, Laura
    Doro, Raffaela
    Di Cataldo, Vanessa
    Francolini, Giulio
    Zani, Margherita
    Visani, Luca
    Meattini, Icro
    Livi, Lorenzo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112
  • [6] A CARDIAC MOTION MODEL TO EVALUATE INTRA-FRACTION DOSIMETRIC VARIATIONS IN RADIOTHERAPY TREATMENTS
    Maffei, Nicola
    Bruno, Meduri
    Francesca, Itta
    Naveed, Ashraf
    Victoria, Gutierrez Maria
    Elisa, D'Angelo
    Ercole, Mazzeo
    Frank, Lohr
    Gabriele, Guidi
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (06)
  • [7] Real-time intra-fraction motion management in breast cancer radiotherapy: analysis of 2028 treatment sessions
    D. Reitz
    G. Carl
    S. Schönecker
    M. Pazos
    P. Freislederer
    M. Niyazi
    U. Ganswindt
    F. Alongi
    M. Reiner
    C. Belka
    S. Corradini
    Radiation Oncology, 13
  • [8] Seminal vesicle inter- and intra-fraction motion during radiotherapy for prostate cancer: A review
    Brand, Victor J.
    Milder, Maaike T. W.
    Christianen, Miranda E. M. C.
    Hoogeman, Mischa S.
    Incrocci, Luca
    RADIOTHERAPY AND ONCOLOGY, 2022, 169 : 15 - 24
  • [9] Quantifying inter- and intra-fraction variations of breast cancer radiotherapy with skin dose measurements
    Hafez, Abdelrahman
    Abdelaziz, Dina M.
    Khalil, Magdy M.
    El-Nagdy, Mohamed S.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04)
  • [10] Factors affecting patient intra-fraction analysis during free-breathing breast cancer radiotherapy
    Verzellesi, Laura
    Orlandi, Matteo
    Botti, Andrea
    Trojani, Valeria
    Paolani, Giulia
    Sghedoni, Roberto
    Iori, Mauro
    Augelli, Camilla
    Berzieri, Chiara
    Casini, Francesca
    Casotti, Linda
    Cinti, Andrea
    Fabbiani, Simone
    Faedda, Francesco
    Ferrarini, Antonella
    Guadagno, Giuseppe
    Moretti, Nadia
    Napolitano, Clemente
    Quarta, Anna
    Raffaelli, Roberta
    Robustelli, Antonia
    Tedeschi, Elisabetta
    Bertoni, Daniele
    Iotti, Cinzia
    Cagni, Elisabetta
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5596 - S5599