Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT

被引:2
|
作者
Catania, Roberta [1 ]
Jia, Leo [1 ]
Haghshomar, Maryam [1 ]
Miller, Frank H. [1 ]
Borhani, Amir A. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 676 N St Clair St, Arkes Family Pavil, Suite 800, Chicago, IL 60611 USA
关键词
Dual-energy CT; Spectral CT; Virtual non-contrast; Virtual unenhanced; Fatty liver; Steatosis; FATTY LIVER-DISEASE; TOMOGRAPHY PHYSICAL PRINCIPLES; COMPUTED-TOMOGRAPHY; QUANTIFICATION; INFILTRATION; ASSOCIATION; DIAGNOSIS; USAGE; MRI;
D O I
10.1016/j.ejrad.2024.111328
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate diagnostic accuracy of virtual non contrast (VNC) images, based on dual-source dualenergy CT (dsDECT), for detection of at least moderate steatosis and to define a threshold value to make this diagnosis on VNC. Methods: This single-institution retrospective study included patients who had multi-phasic protocol dsDECT. Regions of interests were placed in different segments of the liver and spleen on true non-contrast (TNC), VNC, and portal-venous phase (PVP) images. At least moderate steatosis was defined as liver attenuation (LHU) < 40 HU on TNC. Diagnostic performance of VNC to detect steatosis was determined and the new threshold was tested in a validation cohort. Results: 236 patients were included in training cohort. Mean liver attenuation values were 51.3 +/- 10.8 HU and 58.1 +/- 11.5 HU for TNC and VNC (p < 0.001), with a mean difference (VNC - TNC) of 6.8 +/- 6.9 HU. Correlation between TNC and VNC was strong (r = 0.81, p < 0.001). The AUCs of LHU on VNC for detection of hepatic steatosis were 0.92 (95 % Cl: 0.86-0.98), 0.92 (95 % Cl: 0.87-0.97), 0.92 (95 % Cl: 0.86-0.99), 0.91 (95 % Cl: 0.84-0.97), and 0.87 (95 % Cl: 0.80-0.95) for entire liver, left lateral, left medial, right anterior, and right posterior segments, respectively. VNC had sensitivity/specificity of 100 % /42 % when using a threshold of 40 HU; they were 69 % and 95 %, respectively, when using optimized threshold of 46 HU. This threshold showed similar performance in validation cohort (n = 80). Conclusions: Hepatic attenuation on VNC has promising performance for detection of at least moderate steatosis. Proposed threshold of 46 HU provides high specificity and moderate sensitivity to detect steatosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Virtual noncontrast images reveal gouty tophi in contrast-enhanced dual-energy CT: a phantom study
    Khayata, Karim
    Diekhoff, Torsten
    Mews, Juergen
    Schmolke, Sydney
    Kotlyarov, Maximilian
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [42] CSF rhinorrhea: non-contrast CT, contrast-enhanced CT cisternography or combined?
    Lina Tarek Hablas
    Alshimaa Magdy Ammar
    Rehab Mohamed Elnagar
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [43] Using Virtual Non-Contrast CT from Dual-Energy CT to Eliminate the Need for Pre-Contrast CT for Radiation Therapy Planning of Pancreatic Cancer Patients
    Noid, G.
    Tai, A.
    Schott, D.
    Zhu, J.
    Shah, J.
    Paulson, E.
    Prah, D.
    Li, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E368 - E368
  • [44] CSF rhinorrhea: non-contrast CT, contrast-enhanced CT cisternography or combined?
    Hablas, Lina Tarek
    Ammar, Alshimaa Magdy
    Elnagar, Rehab Mohamed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01):
  • [45] Pulmonary Embolism Detection with Dual-Energy CT: Experimental Study of Dual-Source CT in Rabbits
    Zhang, Long-Jiang
    Zhao, Yan-E
    Wu, Sheng-Yong
    Yeh, Benjamin M.
    Zhou, Chang-Sheng
    Hu, Xiao-Bo
    Hu, Qiu-Ju
    Lu, Guang-Ming
    RADIOLOGY, 2009, 252 (01) : 61 - 70
  • [46] Radiation Dose Reduction in Contrast-Enhanced Abdominal CT: Comparison of Photon-Counting Detector CT with 2nd Generation Dual-Source Dual-Energy CT in an oncologic cohort
    Wrazidlo, Robin
    Walder, Lukas
    Estler, Arne
    Gutjahr, Ralf
    Schmidt, Bernhard
    Faby, Sebastian
    Fritz, Jan
    Nikolaou, Konstantin
    Horger, Marius
    Hagen, Florian
    ACADEMIC RADIOLOGY, 2023, 30 (05) : 855 - 862
  • [47] Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection
    Bae, Jae Seok
    Lee, Dong Ho
    Joo, Ijin
    Jeon, Sun Kyung
    Han, Joon Koo
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 : 34 - 40
  • [48] Virtual non-contrast images calculated from dual-energy CT shoulder arthrography improve the detection of intraarticular loose bodies
    Stern, Christoph
    Graf, Dimitri N.
    Bouaicha, Samy
    Wieser, Karl
    Rosskopf, Andrea B.
    Sutter, Reto
    SKELETAL RADIOLOGY, 2022, 51 (08) : 1639 - 1647
  • [49] Sensitivity of virtual non-contrast dual-energy CT urogram for detection of urinary calculi: a systematic review and meta-analysis
    Katherine McCoombe
    Karen Dobeli
    Steven Meikle
    Stacey Llewellyn
    Peter Kench
    European Radiology, 2022, 32 : 8588 - 8596
  • [50] Evaluation of Virtual Non-Contrast Images From a Novel Split-Filter Dual-Energy CT Technique
    Huang, J.
    Szczykutowicz, T.
    Bayouth, J.
    Miller, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3877 - 3877