The application of impantable sensors in the musculoskeletal system: a review

被引:6
作者
Wang, Jinzuo [1 ,2 ]
Chu, Jian [3 ]
Song, Jinhui [3 ]
Li, Zhonghai [1 ,2 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Orthopaed, Dalian, Peoples R China
[2] Key Lab Mol Mech Repair & Remodeling Orthopaed Dis, Dalian, Liaoning, Peoples R China
[3] Dalian Univ Technol, Dept Engn Mech, Dalian, Peoples R China
关键词
implantable sensor; flexible material; joint; hip; knee; spine; fracture; CAPACITIVE PRESSURE SENSOR; IN-VIVO MEASUREMENT; STRAIN-GAUGE; FEMORAL REPLACEMENTS; FORCE MEASUREMENTS; KNEE REPLACEMENT; CONTACT FORCES; LUMBAR SPINE; HIP; IMPLANT;
D O I
10.3389/fbioe.2024.1270237
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
As the population ages and the incidence of traumatic events rises, there is a growing trend toward the implantation of devices to replace damaged or degenerated tissues in the body. In orthopedic applications, some implants are equipped with sensors to measure internal data and monitor the status of the implant. In recent years, several multi-functional implants have been developed that the clinician can externally control using a smart device. Experts anticipate that these versatile implants could pave the way for the next-generation of technological advancements. This paper provides an introduction to implantable sensors and is structured into three parts. The first section categorizes existing implantable sensors based on their working principles and provides detailed illustrations with examples. The second section introduces the most common materials used in implantable sensors, divided into rigid and flexible materials according to their properties. The third section is the focal point of this article, with implantable orthopedic sensors being classified as joint, spine, or fracture, based on different practical scenarios. The aim of this review is to introduce various implantable orthopedic sensors, compare their different characteristics, and outline the future direction of their development and application.
引用
收藏
页数:17
相关论文
共 162 条
  • [1] Liquid Crystal Polymer-Based Miniaturized Fully Implantable Deep Brain Stimulator
    Ahn, Seung-Hee
    Koh, Chin Su
    Park, Minkyung
    Jun, Sang Beom
    Chang, Jin Woo
    Kim, Sung June
    Jung, Hyun Ho
    Jeong, Joonsoo
    [J]. POLYMERS, 2023, 15 (22)
  • [2] Knee adduction moment and development of chronic knee pain in elders
    Amin, S
    Luepongsak, N
    McGibbon, CA
    LaValley, MP
    Krebs, DE
    Felson, DT
    [J]. ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2004, 51 (03): : 371 - 376
  • [3] Evidence of an application of a variable MEMS capacitive sensor for detecting shunt occlusions
    Apigo, David J.
    Bartholomew, Philip L.
    Russell, Thomas
    Kanwal, Alokik
    Farrow, Reginald C.
    Thomas, Gordon A.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [4] An Angstrom-sensitive, differential MEMS capacitor for monitoring the milliliter dynamics of fluids
    Apigo, David J.
    Bartholomew, Philip L.
    Russell, Thomas
    Kanwal, Alokik
    Farrow, Reginald C.
    Thomas, Gordon A.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2016, 251 : 234 - 240
  • [5] Studying the Feasibility of Postoperative Monitoring of Spinal Fusion Progress Using a Self-Powered Fowler-Nordheim Sensor-Data-Logger
    Barri, Kaveh
    Zhang, Qianyun
    Mehta, Darshit
    Chakrabartty, Shantanu
    Debski, Richard
    Alavi, Amir H.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (02) : 710 - 717
  • [6] Thermal Effects during Bone Preparation and Insertion of Osseointegrated Transfemoral Implants
    Benca, Emir
    Ferrante, Beatrice
    Zalaudek, Martin
    Hirtler, Lena
    Synek, Alexander
    Kainberger, Franz M.
    Windhager, Reinhard
    Branemark, Rickard
    Hobusch, Gerhard M.
    Unger, Ewald
    [J]. SENSORS, 2021, 21 (18)
  • [7] A sensor to monitor limb depth in transtibial sockets with locking pin suspension: a technical note
    Bennett, Sam
    Gurrey, Clement
    Wang, Horace
    Weissinger, Mathew
    Larsen, Brian
    Sanders, Joan E.
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2021, 45 (04) : 362 - 367
  • [8] In vivo glenohumeral contact forces -: Measurements in the first patient 7 months postoperatively
    Bergmann, G.
    Graichen, F.
    Bender, A.
    Kaab, M.
    Rohlmann, A.
    Westerhoff, P.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (10) : 2139 - 2149
  • [9] Hip joint contact forces during stumbling
    Bergmann, G
    Graichen, F
    Rohlmann, A
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2004, 389 (01) : 53 - 59
  • [10] High-Tech Hip Implant for Wireless Temperature Measurements In Vivo
    Bergmann, Georg
    Graichen, Friedmar
    Dymke, Joern
    Rohlmann, Antonius
    Duda, Georg N.
    Damm, Philipp
    [J]. PLOS ONE, 2012, 7 (08):