American Society of Biomechanics Journal of Biomechanics Award 2022: Computer models do not accurately predict human muscle passive muscle force and fiber length: Evaluating subject-specific modeling impact on musculoskeletal model predictions

被引:4
作者
Persad, Lomas S. [1 ]
Binder-Markey, Benjamin I. [3 ]
Shin, Alexander Y. [1 ]
Lieber, Richard L. [2 ,4 ,5 ]
Kaufman, Kenton R. [1 ,6 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
[2] Shirley Ryan AbilityLab, Chicago, IL USA
[3] Drexel Univ, Philadelphia, PA USA
[4] Northwestern Univ, Chicago, IL USA
[5] Hines VA Med Ctr, Maywood, IL USA
[6] Mot Anal Lab, 200 First St S, DAHLC 4-214, Rochester, MN 55905 USA
关键词
Passive muscle force; Subject-specific modeling; OpenSim; Gracilis; Intraoperative; PARAMETERS; TENSION; SIMULATION; WRIST;
D O I
10.1016/j.jbiomech.2023.111798
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Musculoskeletal models are valuable for studying and understanding the human body in a variety of clinical applications that include surgical planning, injury prevention, and prosthetic design. Subject-specific models have proven to be more accurate and useful compared to generic models. Nevertheless, it is important to validate all models when possible. To this end, gracilis muscle-tendon parameters were directly measured intra-operatively and used to test model predictions. The aim of this study was to evaluate the benefits and limitations of systematically incorporating subject-specific variables into muscle models used to predict passive force and fiber length. The results showed that incorporating subject-specific values generally reduced errors, although significant errors still existed. Optimization of the modeling parameter "tendon slack length" was explored in two cases: minimizing fiber length error and minimizing passive force error. The results showed that using all subject-specific values yielded the most favorable outcome in both models and optimization cases. However, the trade-off between fiber length error and passive force error will depend on the specific circumstances and research objectives due to significant individual errors. Notably, individual fiber length and passive force errors were as high as 20% and 37% respectively. Finally, the modeling parameter "tendon slack length" did not correlate with any real-world anatomical length.
引用
收藏
页数:11
相关论文
共 37 条
  • [1] Is subject-specific musculoskeletal modelling worth the extra effort or is generic modelling worth the shortcut?
    Akhundov, Riad
    Saxby, David J.
    Diamond, Laura E.
    Edwards, Suzi
    Clausen, Phil
    Dooley, Katherine
    Blyton, Sarah
    Snodgrass, Suzanne J.
    [J]. PLOS ONE, 2022, 17 (01):
  • [2] Incorporating the length-dependent passive-force generating muscle properties of the extrinsic finger muscles into a wrist and finger biomechanical musculoskeletal model
    Binder-Markey, Benjamin I.
    Murray, Wendy M.
    [J]. JOURNAL OF BIOMECHANICS, 2017, 61 : 250 - 257
  • [3] Image-based musculoskeletal modeling: Applications, advances, and future opportunities
    Blemker, Silvia S.
    Asakawa, Deanna S.
    Gold, Garry E.
    Delp, Scott L.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) : 441 - 451
  • [4] Subject-specific muscle properties from diffusion tensor imaging significantly improve the accuracy of musculoskeletal models
    Charles, James P.
    Grant, Barbara
    D'Aout, Kristiaan
    Bates, Karl T.
    [J]. JOURNAL OF ANATOMY, 2020, 237 (05) : 941 - 959
  • [5] Multi-level personalization of neuromusculoskeletal models to estimate physiologically plausible knee joint contact forces in children
    Davico, Giorgio
    Lloyd, David G.
    Carty, Christopher P.
    Killen, Bryce A.
    Devaprakash, Daniel
    Pizzolato, Claudio
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2022, 21 (06) : 1873 - 1886
  • [6] AN INTERACTIVE GRAPHICS-BASED MODEL OF THE LOWER-EXTREMITY TO STUDY ORTHOPEDIC SURGICAL-PROCEDURES
    DELP, SL
    LOAN, JP
    HOY, MG
    ZAJAC, FE
    TOPP, EL
    ROSEN, JM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (08) : 757 - 767
  • [7] Improving Musculoskeletal Model Scaling Using an Anatomical Atlas: The Importance of Gender and Anthropometric Similarity to Quantify Joint Reaction Forces
    Ding, Ziyun
    Tsang, Chui K.
    Nolte, Daniel
    Kedgley, Angela E.
    Bull, Anthony M. J.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (12) : 3444 - 3456
  • [8] Patient-specific musculoskeletal modeling of the hip joint for preoperative planning of total hip arthroplasty: A validation study based on in vivo measurements
    Fischer, Maximilian C. M.
    Eschweiler, Joerg
    Schick, Fabian
    Asseln, Malte
    Damm, Philipp
    Radermacher, Klaus
    [J]. PLOS ONE, 2018, 13 (04):
  • [9] Ultrasound-based subject-specific parameters improve fascicle behaviour estimation in Hill-type muscle model
    Gerus, Pauline
    Rao, Guillaume
    Berton, Eric
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (02) : 116 - 123
  • [10] Harvest of an Entire Gracilis Muscle and Tendon for Use in Functional Muscle Transfer: A Novel Technique
    Giuffre, Jennifer L.
    Bishop, Allen T.
    Shin, Alexander Y.
    [J]. JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2012, 28 (05) : 349 - 358