Does a patient-specific bladder-filling protocol affect bladder volume and dose in postprostatectomy radiotherapy?

被引:1
作者
Yalman, Deniz [1 ]
Koylu, Murat [1 ]
Duran, Ozge [2 ]
机构
[1] Ege Univ, Dept Radiat Oncol, Med Fac, Izmir, Turkiye
[2] Celal Bayar Univ, Dept Radiat Oncol, Med Fac, Manisa, Turkiye
关键词
Bladder filling; Bladder scanner; Cone-beam computed tomography; Prostate cancer; Radiotherapy; BEAM-COMPUTED-TOMOGRAPHY; CONFORMAL RADIOTHERAPY; RADIATION-THERAPY; TARGET VOLUME; PROSTATE; CANCER; RECTUM; VARIABILITY; CONSISTENCY; POSITION;
D O I
10.1007/s11255-023-03814-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
PurposeOur aim is to develop a patient-specific bladder-filling protocol (PSP) using an ultrasound-based bladder scanner (BS) and compare the volumetric and dosimetric parameters with those of the standard filling protocol (SP) in postprostatectomy patients.MethodsTwenty postprostatectomy patients who received salvage radiotherapy (72 Gy/36 fx) were included. For PSP, the patient was asked to drink 500 mL of water after emptying his bladder. Bladder volume was measured using BS every 10 min. Each patient's unique time to reach a 150-200 cc volume was used for simulation and treatment. For the SP, the patient was asked about the feeling of having a full bladder. Organs at risk (OAR) were contoured on cone-beam computed tomography (CBCT) scans that were transferred to the treatment planning system (TPS). Treatment plans were applied to CBCTs. Changes in bladder volume and doses for planning computed tomography (PCT) and CBCT were determined.ResultsIn the SP, there was no significant difference in mean bladder volume for PCT and CBCT (p = 0.139); however, there was a trend for significance in the mean bladder dose (p = 0.074). In PSP, there was no significant difference in the mean bladder volume or dose for PCT and CBCT (p = 0.139 and p = 0.799, respectively). There was a significant difference in terms of mean CBCT bladder volume between the two protocols (p = 0.007), whereas no significant difference was detected in terms of bladder dose (p = 0.130).ConclusionWith PSP, optimal bladder filling was obtained and maintained throughout the whole treatment course, and it was reproducible in every fraction.
引用
收藏
页码:999 / 1006
页数:8
相关论文
共 29 条
[1]   Inter-fraction bladder filling variations and time trends for cervical cancer patients assessed with a portable 3-dimensional ultrasound bladder scanner [J].
Ahmad, Rozilawati ;
Hoogeman, Mischa S. ;
Quint, Sandra ;
Mens, Jan Willem ;
de Pree, Ilse ;
Heijmen, Ben J. M. .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :172-179
[2]   Prostate target volume variations during a course of radiotherapy [J].
Antolak, JA ;
Rosen, II ;
Childress, CH ;
Zagars, GK ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :661-672
[3]   External beam radiotherapy cone beam-computed tomography-based dose calculation [J].
Barateau, A. ;
Celeste, M. ;
Lafond, C. ;
Henry, O. ;
Couespel, S. ;
Simon, A. ;
Acosta, O. ;
de Crevoisier, R. ;
Perichon, N. .
CANCER RADIOTHERAPIE, 2018, 22 (01) :85-100
[4]   The impact of rectal and bladder variability on target coverage during post-prostatectomy intensity modulated radiotherapy [J].
Bell, Linda J. ;
Cox, Jennifer ;
Bade, Thomas ;
Rinks, Marianne ;
Kneebone, Andrew .
RADIOTHERAPY AND ONCOLOGY, 2014, 110 (02) :245-250
[5]   Variability of bladder filling in patients receiving radical radiotherapy to the prostate [J].
Doherty, Una M. ;
McNair, Helen A. ;
Norman, Andrew R. ;
Miles, Elizabeth ;
Hooper, Simon ;
Davies, Mark ;
Lincoln, Naomi ;
Balyckyi, Jan ;
Childs, Peter ;
Dearnaley, David P. ;
Huddart, Robert A. .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (03) :335-340
[6]   Rectal and bladder motion during conformal radiotherapy after radical prostatectomy [J].
Fiorino, C ;
Foppiano, F ;
Franzone, P ;
Broggi, S ;
Castellone, P ;
Marcenaro, M ;
Calandrino, R ;
Sanguineti, G .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (02) :187-195
[7]   Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy [J].
Hatton, Joan ;
McCurdy, Boyd ;
Greer, Peter B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) :N329-N346
[8]   Prostate Bed Radiation Therapy: The Utility of Ultrasound Volumetric Imaging of the Bladder [J].
Haworth, A. ;
Paneghel, A. ;
Bressel, M. ;
Herschtal, A. ;
Pham, D. ;
Tai, K. H. ;
Oates, R. ;
Gawthrop, J. ;
Cray, A. ;
Foroudi, F. .
CLINICAL ONCOLOGY, 2014, 26 (12) :789-796
[9]   Verification of target position in the post-prostatectomy cancer patient using cone beam CT [J].
Haworth, A. ;
Paneghel, A. ;
Herschtal, A. ;
Duchesne, G. ;
Williams, S. ;
Tai, K. H. ;
Kron, T. ;
Roxby, P. ;
Soteriou, S. ;
Laferlita, M. ;
Foroudi, F. .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (02) :212-220
[10]   Assessing the daily consistency of bladder filling using an ultrasonic Bladderscan device in men receiving radical conformal radiotherapy for prostate cancer [J].
Hynds, S. ;
McGarry, C. K. ;
Mitchell, D. M. ;
Early, S. ;
Shum, L. ;
Stewart, D. P. ;
Harney, J. A. ;
Cardwell, C. R. ;
O'Sullivan, J. M. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1005) :813-818