Research on simulation and detection of space electric field distribution of deteriorated insulators in three-phase over-head transmission lines

被引:0
|
作者
Jia, Jun [1 ]
Wang, Maofei [1 ]
Dai, Yongdong [1 ]
Zhang, Haoling [1 ]
Gao, Song [2 ]
Wang, Shenyu [1 ]
机构
[1] Taizhou Power Supply Co, State Grid Jiangsu Elect Power Co Ltd, Taizhou, Jiangsu, Peoples R China
[2] State Grid Jiangsu Elect Power Co, Elect Power Res Inst, Nanjing, Jiangsu, Peoples R China
关键词
Insulator; electric field distribution; three-phase electrification; non-contact type;
D O I
10.3233/JCM-226658
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Operation accidents caused by deteriorated insulators occur from time to time, which poses a direct threat to the safe and stable operation of transmission lines. Much research has been done at home and abroad on the degradation mechanism of deteriorated insulators, the electric field distribution characteristics of insulator strings and the influence of deteriorated insulators on the space electric field, but there is little research on the influence of three-phase electrification on the space electric field of insulator strings. Therefore, this paper studies the simulation and detection of electric field distribution of deteriorated insulators in three-phase transmission lines. First, the difference between three-phase electrification and single-phase electrification on the space electric field of insulator strings is simulated and analyzed, and the influence of deteriorated insulators on the space electric field distribution of insulator strings under three-phase electrification is studied. Second, based on simulation results, a detection method for deteriorated insulators in three-phase overhead trans-mission lines is proposed, and a non-contact space electric field measurement device based on Unmanned Aerial Vehicle (UAV) is developed. Finally, a Unmanned Aerial Vehicle inspection system is used to test the transmission lines in combination with an electric power department, and the simulation results and the effectiveness of the proposed detection method are verified. Results show the electric field distribution of insulator strings is obviously different between three-phase electrification and single-phase electrification, and when the detection distance is 300 mm, the proposed detection method and device can effectively identify deteriorated insulators in three-phase transmission lines.
引用
收藏
页码:1451 / 1466
页数:16
相关论文
共 40 条
  • [21] Three-phase Representation of Harmonic Signals for Application to Non-contact Diagnostics of Electric Power Transmission Lines
    Greitans, Modris
    Hermanis, Evalds
    PROCEEDINGS ELMAR-2008, VOLS 1 AND 2, 2008, : 427 - 430
  • [22] Nonfault Detection for Three-phase Reclosure in Reactor-compensated Transmission Lines Based on Fault Location
    Shao, Wenquan
    Liu, Yue
    Zhang, Wangni
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 974 - 977
  • [23] Sheds configuration optimization of AC composite insulators used in AC transmission lines at icing areas based on electric field distribution
    Jiang, Xingliang
    Liu, Yu
    Zhang, Zhijin
    Hu, Jianlin
    Yin, Fanghui
    Xiang, Ze
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (01): : 210 - 217
  • [24] Electric field analysis for a static induction type of voltage sensor in three-phase power distribution systems
    Shimada, H
    Furukawa, T
    Ohchi, M
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1998, 145 (04) : 437 - 443
  • [25] Research on Resonance Point of Three-Phase Short Circuit Fault on Half-Wavelength AC Transmission Lines
    Zhang Q.
    Li C.
    Wan L.
    2017, Power System Technology Press (41): : 2743 - 2748
  • [26] Electric Field Distribution Calculation and Analysis of Composite Insulators Operating on Double Circuit Transposition Tower in 500kV Transmission Lines
    Guo, Chenjun
    Liu, Lishuai
    Yu, Hong
    Ma, Yi
    Mei, Hongwei
    Wang, Liming
    2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 486 - 489
  • [27] Research on Diagnostic Methods for Zero-Value Insulators in 110 kV Transmission Lines Based on Spatial Distribution Characteristics of Electric Fields
    Zheng, Lei
    Yin, Pengxiang
    Li, Jian
    Liu, Hui
    Li, Tao
    Luo, Hao
    ENERGIES, 2025, 18 (06)
  • [28] Integrated Transmission and Distribution System Power Flow and Dynamic Simulation Using Mixed Three-Sequence/Three-Phase Modeling
    Huang, Qiuhua
    Vittal, Vijay
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (05) : 3704 - 3714
  • [29] Integrated Transmission and Distribution System Power Flow and Dynamic Simulation Using Mixed Three-Sequence/Three-Phase Modeling
    Huang, Qiuhua
    Vittal, Vijay
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [30] An Intelligent Detection Device of Temporary Grounding Wire for Distribution Lines Based on Three-phase Symmetrical Voltage Injection
    Guan, Fei
    Cheng, Le Feng
    Qu, Kai Ping
    Chen, Yi Xuan
    Xu, Mao Xin
    Yu, Tao
    Lu, Jun
    Liu, Ming
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY V, 2015, : 1385 - 1392