Research on simulation and detection of space electric field distribution of deteriorated insulators in three-phase over-head transmission lines

被引:0
|
作者
Jia, Jun [1 ]
Wang, Maofei [1 ]
Dai, Yongdong [1 ]
Zhang, Haoling [1 ]
Gao, Song [2 ]
Wang, Shenyu [1 ]
机构
[1] Taizhou Power Supply Co, State Grid Jiangsu Elect Power Co Ltd, Taizhou, Jiangsu, Peoples R China
[2] State Grid Jiangsu Elect Power Co, Elect Power Res Inst, Nanjing, Jiangsu, Peoples R China
关键词
Insulator; electric field distribution; three-phase electrification; non-contact type;
D O I
10.3233/JCM-226658
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Operation accidents caused by deteriorated insulators occur from time to time, which poses a direct threat to the safe and stable operation of transmission lines. Much research has been done at home and abroad on the degradation mechanism of deteriorated insulators, the electric field distribution characteristics of insulator strings and the influence of deteriorated insulators on the space electric field, but there is little research on the influence of three-phase electrification on the space electric field of insulator strings. Therefore, this paper studies the simulation and detection of electric field distribution of deteriorated insulators in three-phase transmission lines. First, the difference between three-phase electrification and single-phase electrification on the space electric field of insulator strings is simulated and analyzed, and the influence of deteriorated insulators on the space electric field distribution of insulator strings under three-phase electrification is studied. Second, based on simulation results, a detection method for deteriorated insulators in three-phase overhead trans-mission lines is proposed, and a non-contact space electric field measurement device based on Unmanned Aerial Vehicle (UAV) is developed. Finally, a Unmanned Aerial Vehicle inspection system is used to test the transmission lines in combination with an electric power department, and the simulation results and the effectiveness of the proposed detection method are verified. Results show the electric field distribution of insulator strings is obviously different between three-phase electrification and single-phase electrification, and when the detection distance is 300 mm, the proposed detection method and device can effectively identify deteriorated insulators in three-phase transmission lines.
引用
收藏
页码:1451 / 1466
页数:16
相关论文
共 40 条
  • [1] Live-Line Detection of Deteriorated Insulators on Overhead Transmission Lines Based on Electric Field Distribution
    Wu, Shaocheng
    Wang, Linong
    Song, Bin
    Gao, Jiachen
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1687 - 1695
  • [2] Identification of Deteriorated Porcelain Insulators for Transmission Lines Based on Electric Field Distribution Measurement Method
    Zheng, Weigang
    Ma, Yiling
    Geng, Lina
    Zhang, Zhongrui
    Tang, Hong
    Fan, Qirui
    JOURNAL OF ELECTRONIC MATERIALS, 2025,
  • [3] Research on the Three-Phase Voltage Inversion Algorithm of Transmission Lines Based on Electric Field Coupling
    Zhang, Zheming
    Liu, Zongwei
    Geng, Pulong
    Ma, Yuan
    2024 6TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES 2024, 2024, : 42 - 47
  • [4] Influence of Deteriorated Porcelain Insulator on Electric Field and Potential Distribution of Insulators Strings in 110kV Transmission Lines
    Xu Changfu
    Hu Chengbo
    Xu Jiayuan
    Liu Yunpeng
    Zhang Kaiyuan
    Pei Shaotong
    2017 IEEE INTERNATIONAL CONFERENCE ON SMART GRID AND SMART CITIES (ICSGSC), 2017, : 162 - 166
  • [5] Identification of lines of electric lines of three-phase distribution networks in the composition of ASMAE
    Omorov, Turatbek
    Takyrbashev, Beishenaly
    Zakiriaev, Kubanychbek
    METHODOLOGICAL PROBLEMS IN RELIABILITY STUDY OF LARGE ENERGY SYSTEMS (RSES 2017), 2017, 25
  • [6] Simulation Calculation for Total Electric Field of Three-Phase Power Cable
    Guan, Huanmei
    Qian, Hang
    Kong, Haiyang
    Wang, Xuan
    Fang, Fuxin
    Hu, Guanying
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [7] Study on the Formation of the Electric Field around Three-phase Insulators in 110kV Transmission Tower and Its Influence on Flashover Voltage
    Zhang, Yaqi
    Han, Yongxia
    Yang, Jie
    Ruan, Yaoxuan
    Liao, Yifan
    Liu, Gang
    Jia, Lei
    Li, Licheng
    Wang, Feng
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3521 - 3527
  • [8] Analysis of physically symmetrical lossy three-phase transmission lines in terms of space vectors
    Leva, S
    Morando, AP
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 873 - 882
  • [9] Research on UAV Three-Phase Transmission Line Tracking and Localization Method Based on Electric Field Sensor Array
    Suo, Chunguang
    Zhao, Jiawen
    Zhang, Wenbin
    Li, Peng
    Huang, Rujin
    Zhu, Junyu
    Tan, Xiangyu
    SENSORS, 2021, 21 (24)
  • [10] Theoretical Analysis, Simulation and Optimization of Electric Field on the Three-Phase Electrodynamic Screen
    Baqraf, Saeed A.
    Gondal, Mohammed A.
    Dastageer, Mohamed. A.
    Rao, Saleem
    Al-Aswad, Abdulaziz
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2025, 50 (01) : 597 - 610