Predicting the net administered activity in 90Y-radioembolization patients from post-procedure 90Y-SPECT/CT

被引:3
作者
Henry, Eric C. [1 ]
Lopez, Benjamin [1 ]
Mahvash, Armeen [2 ]
Thomas, Matthew A. [1 ]
Kappadath, Srinivas C. [1 ,3 ]
机构
[1] UT MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX USA
[2] UT MD Anderson Canc Ctr, Dept Intervent Radiol, Houston, TX USA
[3] UT MD Anderson Canc Ctr, Unit 1352, Dept Imaging Phys, 1155 Pressler St, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
quantification; radioembolization; SIRT; SPECT; CT; Yttrium-90; HEPATOCELLULAR-CARCINOMA; Y-90; RADIOEMBOLIZATION; MICROSPHERES; COMPENSATION; CALIBRATION;
D O I
10.1002/mp.16540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe calculation of the net administered activity (A(admin)) in patients undergoing Y-90-radioembolization is essential for dosimetry and radiation safety, yet current methods for measuring residual Y-90 activity are often associated with high uncertainty. Therefore, an accurate, robust, and clinically viable method for the determination of A(admin) across approved Y-90 microsphere devices is desirable. PurposeWe report on a novel method to determine A(admin) by leveraging the quantitative capabilities of SPECT/CT to measure Y-90-emission in vivo from patients following Y-90-radioembolization with glass or resin microspheres. Methods(90)Y-SPECT/CT attenuation-corrected count data from 147 sequential Y-90-radioembolization patients was used for this analysis. A(admin) was calculated as part of routine clinical practice via the exposure rate differences between the initial Y-90-vial and the Y-90-residual jar. This served as our gold standard measure of A(admin). Patient data for each microsphere device were separated into training and testing cohorts to first develop regression models and then to independently assess model performance. The training cohorts were divided into four groups: first, based on the microsphere device (glass or resin), and second, based on the SPECT volume used to calculate counts (the full SPECT field of view (FOV) or liver only (VOIliver)). Univariate linear regression models were generated for each group to predict A(admin) based on Y-90-SPECT data from the training cohorts. Leave-one-out cross validation was implemented to estimate variability in model parameters. To assess performance, linear models derived from the training cohort were applied to Y-90-SPECT data from the testing cohort. A comparison of the models between microspheres devices was also performed. ResultsLinear models derived from the glass and resin training cohorts demonstrated a strong, positive correlation between Y-90-SPECT image counts and A(admin) for VOIliver and FOV with R-2 > 0.98 in all cases. In the glass training cohort, model accuracy (100%-absolute mean prediction error) and precision (95% prediction intervals of mean prediction error) were 99.0% and 15.4% for the VOIliver and 99.7% and 17.5% for the FOV models, respectively. In the resin training cohort, the corresponding values were 98.6% and 16.7% for VOIliver and > 99.9% and 11.4% for the FOV models, respectively. The application of these linear models to Y-90-SPECT data from the testing cohort showed A(admin) prediction errors to have high accuracy and precision for both microsphere devices. For the glass testing cohort, accuracy (precision) was 96.9% (19.6%) and 98.8% (21.1%) for the VOIliver and FOV models, respectively. The corresponding values for the resin training cohort were 97.3% (26.2%) and 98.5% (25.7%) for the VOIliver and FOV models, respectively. The slope of the linear models between the two microsphere devices was observed to be significantly different with resin microspheres generating 48%-49% more SPECT counts for equivalent Y-90 activity based on each device manufacturer's activity calibration process. Conclusion(90)Y-SPECT image counts can reliably predict (accuracy > 95% and precision < 18%) A(admin) after Y-90-radioembolization, with performance characteristics essentially equivalent for both glass and resin microspheres. There is a clear indication that activity calibrations are fundamentally different between the two microsphere devices.
引用
收藏
页码:7003 / 7015
页数:13
相关论文
共 50 条
  • [21] Radioembolization with 90Y-labeled microspheres: Post-therapeutic therapy validation with Bremsstrahlung-SPECT
    Grosser, Oliver S.
    Nultsch, Madeleine
    Laatz, Kathleen
    Ulrich, Gerd
    Seidensticker, Ricarda
    Pethe, Annette
    Dudeck, Oliver
    Pech, Maciej
    Knoop, Bernd O.
    Ricke, Jens
    Amthauer, Holger
    Geworski, Lilli
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (04): : 274 - 280
  • [22] Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization
    Kao, Yung Hsiang
    Tan, Andrew Eik Hock
    Burgmans, Mark Christiaan
    Irani, Farah Gillian
    Khoo, Li Ser
    Lo, Richard Hoau Gong
    Tay, Kiang Hiong
    Tan, Bien Soo
    Chow, Pierce Kah Hoe
    Ng, David Chee Eng
    Goh, Anthony Soon Whatt
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) : 559 - 566
  • [23] FDG PET/CT as a Prognostic Test After 90Y Radioembolization in Patients With Metastatic Hepatic Disease
    Zalom, Martina
    Yu, Run
    Friedman, Marc
    Bresee, Catherine
    Waxman, Alan
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (09) : 862 - 865
  • [24] Total Lesion Glycolysis on 18F-FDG PET/CT Is a Better Prognostic Factor Than Tumor Dose on 90Y PET/CT in Patients With Hepatocellular Carcinoma Treated With 90Y Transarterial Radioembolization
    Hwang, Sang Hyun
    Hong, Hye-Suk
    Kim, Dongwoo
    Kim, Gyoung Min
    Lee, Hye Won
    Lee, Misu
    Kim, Do Young
    Park, Mi-Ae
    Yun, Mijin
    CLINICAL NUCLEAR MEDICINE, 2022, 47 (06) : E437 - E443
  • [25] Optimization of Y-90 Radioembolization Imaging for Post-Treatment Dosimetry on a Long Axial Field-of-View PET/CT Scanner
    Linder, Pia M.
    Lan, Wenhong
    Trautwein, Nils F.
    Brosch-Lenz, Julia
    von Beschwitz, Sebastian
    Kupferschlaeger, Juergen
    Reischl, Gerald
    Groezinger, Gerd
    Dittmann, Helmut
    la Fougere, Christian
    Schmidt, Fabian P.
    DIAGNOSTICS, 2023, 13 (22)
  • [26] Evaluation of different CT maps for attenuation correction and segmentation in static 99mTc-MAA SPECT/CT for 90Y radioembolization treatment planning: A simulation study
    Lu, Zhonglin
    Chen, Gefei
    Lin, Kuan-Heng
    Wu, Tung-Hsin
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2021, 48 (07) : 3842 - 3851
  • [27] Radioembolization with 90Y-Labelled Resin Microspheres in Patients with Liver Metastases from Neuroendocrine Tumors
    Ebeling-Barbier, C.
    Garske-Roman, U.
    Antonodimitrakis, P.
    Sandstrom, M.
    Nyman, R.
    Granberg, D.
    NEUROENDOCRINOLOGY, 2015, 102 (1-2) : 136 - 137
  • [28] Tc-99m sulfur colloid SPECT-CT and assessment of functional liver reserve after Y90 radioembolization: A case report
    Chan, YeeMei
    Luk, WingHang
    Cheng, LikFai
    Chan, HoFung
    Pan, N. Y.
    Ma, KaFai
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2019, 62 : 89 - 93
  • [29] CT-free attenuation and Monte-Carlo based scatter correction-guided quantitative 90Y-SPECT imaging for improved dose calculation using deep learning
    Mansouri, Zahra
    Salimi, Yazdan
    Wolf, Nicola Bianchetto
    Mainta, Ismini
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025,
  • [30] Automated segmentation of lung, liver, and liver tumors from Tc-99m MAA SPECT/CT images for Y-90 radioembolization using convolutional neural networks
    Chaichana, Anucha
    Frey, Eric C.
    Teyateeti, Ajalaya
    Rhoongsittichai, Kijja
    Tocharoenchai, Chiraporn
    Pusuwan, Pawana
    Jangpatarapongsa, Kulachart
    MEDICAL PHYSICS, 2021, 48 (12) : 7877 - 7890